Focused ultrasound treatment of VX2 tumors controlled by local harmonic motion.

Laura Curiel1, Yuexi Huang, Natalia Vykhodtseva, Kullervo Hynynen.   

Abstract

The purpose of this study was to evaluate the feasibility of using localized harmonic motion (LHM) to monitor and control focused ultrasound surgery (FUS) in VX2 tumors in vivo. FUS exposures were performed on 13 VX2 tumors implanted in nine rabbits. The same transducer induced coagulation and generated a localized oscillatory motion by periodically varying the radiation force. A separate diagnostic ultrasound transducer tracked motion by cross-correlating echo signals at different instances. A threshold in motion amplitude was instituted to cease exposure. Coagulation was confirmed by T2-weighted MR images, thermal dose obtained through MR thermometry and histological examinations. For tumor locations achieving coagulation, the LHM amplitude was 9% (p = 0.04) to 57% (p < 0.0001) lower than that before exposure. Control was successful for 74 (69%) out of 108 cases, with 52 (48%) reaching the threshold and achieving coagulation and 22 (21%) never reaching threshold nor coagulating. For the 34 (31%) unsuccessful exposures, 16 (15%) never reached the threshold but coagulation occurred, and 18 (16%) reached threshold without coagulation confirmed. Noise or radio-frequency signal changes explained motion over- or underestimation in 24 (22%) cases; the remaining 10 (9%) had other causes of error. The control was generally successful, but sudden change or noise in the acquired echo signal caused failure. Coagulation after exposure could be validated by comparing amplitudes before and after exposure.

Entities:  

Mesh:

Year:  2009        PMID: 19436103     DOI: 10.1088/0031-9155/54/11/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

Review 2.  Medical ultrasound: imaging of soft tissue strain and elasticity.

Authors:  Peter N T Wells; Hai-Dong Liang
Journal:  J R Soc Interface       Date:  2011-06-16       Impact factor: 4.118

Review 3.  Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

Authors:  Kullervo Hynynen; Ryan M Jones
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

Review 4.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

5.  Localized harmonic motion imaging for focused ultrasound surgery targeting.

Authors:  Laura Curiel; Kullervo Hynynen
Journal:  Ultrasound Med Biol       Date:  2011-06-16       Impact factor: 2.998

6.  Arterial input function calculation in dynamic contrast-enhanced MRI: an in vivo validation study using co-registered contrast-enhanced ultrasound imaging.

Authors:  Hatef Mehrabian; Chaitanya Chandrana; Ian Pang; Rajiv Chopra; Anne L Martel
Journal:  Eur Radiol       Date:  2012-03-27       Impact factor: 5.315

7.  Harmonic motion imaging for abdominal tumor detection and high-intensity focused ultrasound ablation monitoring: an in vivo feasibility study in a transgenic mouse model of pancreatic cancer.

Authors:  Hong Chen; Gary Y Hou; Yang Han; Thomas Payen; Carmine F Palermo; Kenneth P Olive; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-09       Impact factor: 2.725

8.  Real-Time Spatiotemporal Control of High-Intensity Focused Ultrasound Thermal Ablation Using Echo Decorrelation Imaging in ex Vivo Bovine Liver.

Authors:  Mohamed A Abbass; Jakob K Killin; Neeraja Mahalingam; Fong Ming Hooi; Peter G Barthe; T Douglas Mast
Journal:  Ultrasound Med Biol       Date:  2017-10-23       Impact factor: 2.998

9.  Effect of ultrasound on the permeability of vascular wall to nano-emulsion droplets.

Authors:  Dhaval Thakkar; Roohi Gupta; Kenneth Monson; Natalya Rapoport
Journal:  Ultrasound Med Biol       Date:  2013-07-09       Impact factor: 2.998

10.  Optimized Echo Decorrelation Imaging Feedback for Bulk Ultrasound Ablation Control.

Authors:  Mohamed A Abbass; Allison-Joy Garbo; Neeraja Mahalingam; Jakob K Killin; T Douglas Mast
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-06-14       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.