Literature DB >> 19425056

Multiecho time-resolved acquisition (META): a high spatiotemporal resolution Dixon imaging sequence for dynamic contrast-enhanced MRI.

Manojkumar Saranathan1, Dan Rettmann, Ersin Bayram, Christine Lee, James Glockner.   

Abstract

PURPOSE: To evaluate a new dynamic contrast-enhanced (DCE) imaging technique called multiecho time-resolved acquisition (META) for abdominal/pelvic imaging. META combines an elliptical centric time-resolved three-dimensional (3D) spoiled gradient-recalled echo (SPGR) imaging scheme with a Dixon-based fat-water separation algorithm to generate high spatiotemporal resolution volumes.
MATERIALS AND METHODS: Twenty-three patients referred for hepatic metastases or renal masses were imaged using the new META sequence and a conventional fat-suppressed 3D SPGR sequence on a 3T scanner. In 12 patients, equilibrium-phase 3D SPGR images acquired immediately after META were used for comparing the degree and homogeneity of fat suppression, artifacts, and overall image quality. In the remaining 11 of 23 patients, DCE 3D SPGR images acquired in a previous or subsequent examination were used for comparing the efficiency of arterial phase capture in addition to the qualitative analysis for the degree and homogeneity of fat suppression, artifacts, and overall image quality.
RESULTS: META images were determined to be significantly better than conventional 3D SPGR images for degree and uniformity of fat suppression and ability to visualize the arterial phase. There were no significant differences in artifact levels or overall image quality.
CONCLUSION: META is a promising high spatiotemporal resolution imaging sequence for capturing the fast dynamics of hyperenhancing hepatic lesions and provides robust fat suppression even at 3T.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19425056     DOI: 10.1002/jmri.21750

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Sampling strategies for subsampled segmented EPI PRF thermometry in MR guided high intensity focused ultrasound.

Authors:  Henrik Odéen; Nick Todd; Mahamadou Diakite; Emilee Minalga; Allison Payne; Dennis L Parker
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

2.  DIfferential Subsampling with Cartesian Ordering (DISCO): a high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging.

Authors:  Manojkumar Saranathan; Dan W Rettmann; Brian A Hargreaves; Sharon E Clarke; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2012-02-14       Impact factor: 4.813

3.  Patch based reconstruction of undersampled data (PROUD) for high signal-to-noise ratio and high frame rate contrast enhanced liver imaging.

Authors:  Mitchell A Cooper; Thanh D Nguyen; Bo Xu; Martin R Prince; Michael Elad; Yi Wang; Pascal Spincemaille
Journal:  Magn Reson Med       Date:  2014-12-06       Impact factor: 4.668

4.  Time-resolved contrast-enhanced MR angiography with single-echo Dixon fat suppression.

Authors:  Eric G Stinson; Joshua D Trzasko; Norbert G Campeau; James F Glockner; John Huston; Phillip M Young; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2018-02-27       Impact factor: 4.668

5.  Dixon-type and subtraction-type contrast-enhanced magnetic resonance angiography: A theoretical and experimental comparison of SNR and CNR.

Authors:  Eric G Stinson; Joshua D Trzasko; Paul T Weavers; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2014-07-17       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.