Literature DB >> 19416278

A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report.

Wilfried K Kleis1, Peer W Kämmerer, Sinsa Hartmann, Bilal Al-Nawas, Wilfried Wagner.   

Abstract

BACKGROUND: There is a lack of clinical studies on the self-aligning attachment system (Locator(R); Zest Anchors, Inc. homepage, Escondido, CA, USA) for two-implant-retained overdentures in the edentulous mandible. Therefore, a comparison of the Locator with two traditional designs (a rotational gold matrix and a rubber O-ring type) in clinical 1-year use was conducted.
MATERIALS AND METHODS: From 2003 to 2007, 60 patients received two Osseotite(R) TG Standard implants (BIOMET 3i Implant Innovations, Palm Beach Gardens, FL, USA) in the intraforaminal area of the edentulous mandible. The implants were left unloaded for 3.5 months, randomized to three different attachment systems, and loaded through a mandibular overdenture. Twenty-three patients received a self-aligning attachment system (Locator) and 33 patients a ball attachment (Dal-Ro(R)[BIOMET 3i Implant Innovations]n = 25; TG-O-Ring(R)[Cendres & Metaux SA, Biel-Bienne, Switzerland]n = 8). After 12 months of delivery of the overdentures, the oral situation was evaluated: prosthodontic maintenance and biologic complications, subjective patients' experience, and oral health-related life quality (Oral Health Impact Profile [OHIP-G 49]).
RESULTS: After 1-year of clinical service, 8 of 120 implants were lost (9.6%). The Locator system brought up 34 prosthetic complications, especially the need for change of the male parts or activation because of loss of retention. The TG-O-Ring patients showed 14 complications, most of them the change of the O-Rings. The patients with the Dal-Ro abutment had seven minor complications in 12 months of clinical use. Biologic complications and patients' oral health-related life quality showed no significant difference among the three experimental groups.
CONCLUSIONS: Prosthodontic maintenance was restricted to loss of retention for all systems. Within the observation period of this study, the self-aligning attachment system showed a higher rate of maintenance than the ball attachments. The patients' oral health-related life qualities as well as the biologic parameters do not differ when using the three abutment systems.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19416278     DOI: 10.1111/j.1708-8208.2009.00154.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  28 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Attitudes of general dental practitioners to the maintenance of Locator retained implant overdentures.

Authors:  J W Vere; S Eliyas; P F Wragg
Journal:  Br Dent J       Date:  2014-02       Impact factor: 1.626

3.  Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses.

Authors:  Silvia Brandt; Jan Brandt; Ali-Reza Ketabi; Hans-Christoph Lauer; Anna Kunzmann
Journal:  Clin Oral Investig       Date:  2018-05-19       Impact factor: 3.573

Review 4.  Do ball-type attachment systems for overdenture result in better patient-satisfaction? A systematic review of randomized crossover clinical trial.

Authors:  Cleber Davi Del Rei Daltro Rosa; Rafaella de Souza Leão; Cátia Maria Fonseca Guerra; Eduardo Piza Pellizzer; Bruno Gustavo da Silva Casado; Sandra Lúcia Dantas de Moraes
Journal:  Saudi Dent J       Date:  2021-03-14

5.  Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: a two-year prospective study.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-06-18

6.  Attachment systems for mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Jeong-Yol Lee; Sang-Wan Shin; S Ross Bryant
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

Review 7.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

Review 8.  Rehabilitation with implant-supported overdentures in total edentulous patients: A review.

Authors:  Juan F Martínez-Lage-Azorín; Gustavo Segura-Andrés; Joan Faus-López; Rubén Agustín-Panadero
Journal:  J Clin Exp Dent       Date:  2013-12-01

9.  Performance of attachments used in implant-supported overdentures: review of trends in the literature.

Authors:  Damian J Lee
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

10.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.