OBJECTIVE: We wanted to evaluate the impact of two reconstruction algorithms (halfscan and multisector) on the image quality and the accuracy of measuring the severity of coronary stenoses by using a pulsating cardiac phantom with different heart rates (HRs). MATERIALS AND METHODS: Simulated coronary arteries with different stenotic severities (25, 50, 75%) and different luminal diameters (3, 4, 5 mm) were scanned with a fixed pitch of 0.16 and a 0.35 second gantry rotation time on a 64-slice multidetector CT. Both reconstruction algorithms (halfscan and multisector) were applied to HRs of 40-120 beats per minute (bpm) at 10 bpm intervals. Three experienced radiologists visually assessed the image quality and they manually measured the stenotic severity. RESULTS: Fewer measurement errors occurred with multisector reconstruction (p = 0.05), a slower HR (p < 0.001) and a larger luminal diameter (p = 0.014); measurement errors were not related with the observers or the stenotic severity. There was no significant difference in measurements as for the reconstruction algorithms below an HR of 70 bpm. More nonassessable segments were visualized with halfscan reconstruction (p = 0.004) and higher HRs (p < 0.001). Halfscan reconstruction had better quality scores when the HR was below 60 bpm, while multisector reconstruction had better quality scores when the HR was above 90 bpm. For the HRs between 60 and 90 bpm, both reconstruction modes had similar quality scores. With excluding the nonassessable segments, both reconstruction algorithms achieved a similar mean measured stenotic severity and similar standard deviations. CONCLUSION: At a higher HR (above 90 bpm), multisector reconstruction had better temporal resolution, fewer nonassessable segments, better quality scores and better accuracy of measuring the stenotic severity in this phantom study.
OBJECTIVE: We wanted to evaluate the impact of two reconstruction algorithms (halfscan and multisector) on the image quality and the accuracy of measuring the severity of coronary stenoses by using a pulsating cardiac phantom with different heart rates (HRs). MATERIALS AND METHODS: Simulated coronary arteries with different stenotic severities (25, 50, 75%) and different luminal diameters (3, 4, 5 mm) were scanned with a fixed pitch of 0.16 and a 0.35 second gantry rotation time on a 64-slice multidetector CT. Both reconstruction algorithms (halfscan and multisector) were applied to HRs of 40-120 beats per minute (bpm) at 10 bpm intervals. Three experienced radiologists visually assessed the image quality and they manually measured the stenotic severity. RESULTS: Fewer measurement errors occurred with multisector reconstruction (p = 0.05), a slower HR (p < 0.001) and a larger luminal diameter (p = 0.014); measurement errors were not related with the observers or the stenotic severity. There was no significant difference in measurements as for the reconstruction algorithms below an HR of 70 bpm. More nonassessable segments were visualized with halfscan reconstruction (p = 0.004) and higher HRs (p < 0.001). Halfscan reconstruction had better quality scores when the HR was below 60 bpm, while multisector reconstruction had better quality scores when the HR was above 90 bpm. For the HRs between 60 and 90 bpm, both reconstruction modes had similar quality scores. With excluding the nonassessable segments, both reconstruction algorithms achieved a similar mean measured stenotic severity and similar standard deviations. CONCLUSION: At a higher HR (above 90 bpm), multisector reconstruction had better temporal resolution, fewer nonassessable segments, better quality scores and better accuracy of measuring the stenotic severity in this phantom study.
Authors: Stephan Wicky; Michael Rosol; Udo Hoffmann; Michael Graziano; Kent E Yucel; Thomas J Brady Journal: J Comput Assist Tomogr Date: 2003 May-Jun Impact factor: 1.826
Authors: Koen Nieman; Filippo Cademartiri; Pedro A Lemos; Rolf Raaijmakers; Peter M T Pattynama; Pim J de Feyter Journal: Circulation Date: 2002-10-15 Impact factor: 29.690
Authors: Stephen Schroeder; Andreas F Kopp; Axel Kuettner; Christof Burgstahler; Christian Herdeg; Martin Heuschmid; Andreas Baumbach; Claus D Claussen; Karl R Karsch; Ludger Seipel Journal: Clin Imaging Date: 2002 Mar-Apr Impact factor: 1.605
Authors: Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach Journal: Circulation Date: 2003-02-11 Impact factor: 29.690
Authors: Marc Dewey; Michael Laule; Lasse Krug; Dirk Schnapauff; Patrik Rogalla; Wolfgang Rutsch; Bernd Hamm; Alexander Lembcke Journal: Invest Radiol Date: 2004-04 Impact factor: 6.016
Authors: Jeong Bin Park; Yeon Joo Jeong; Geewon Lee; Nam Kyung Lee; Jin You Kim; Ji Won Lee Journal: Korean J Radiol Date: 2018-12-27 Impact factor: 3.500