| Literature DB >> 19409114 |
Sindre Svedahl1, Kristin Svendsen, Torgunn Qvenild, Ann Kristin Sjaastad, Bjørn Hilt.
Abstract
BACKGROUND: Exposure to cooking fumes may have different deleterious effects on the respiratory system. The aim of this study was to look at possible effects from inhalation of cooking fumes on pulmonary function.Entities:
Year: 2009 PMID: 19409114 PMCID: PMC2685804 DOI: 10.1186/1745-6673-4-9
Source DB: PubMed Journal: J Occup Med Toxicol ISSN: 1745-6673 Impact factor: 2.646
Personal exposure to particles from cooking fumes and personal characteristics of the twenty-four volunteers who participated in the study.
| Group and subject number | Personal | Sex* | Age (Years) | Height (cm) | Weight (Kg) | Current cold | Known allergy | Current medication | |
| A | 1 | 13.8 | F | 24 | 173 | 65 | No | No | No |
| 2 | 14.4 | M | 25 | 193 | 105 | No | No | No | |
| 3 | 14.9 | F | 24 | 163 | 61 | No | No | Yes | |
| 4 | 13.9 | F | 21 | 152 | 45 | No | No | No | |
| 5 | 18.9 | M | 24 | 183 | 90 | Yes | No | No | |
| 6 | 20.8 | F | 22 | 166 | 66 | No | Yes | Yes | |
| 7 | 24.1 | M | 26 | 193 | 95 | No | No | No | |
| 8 | 24.4 | M | 28 | 177 | 75 | No | No | No | |
| 9 | 15.4 | M | 26 | 184 | 76 | No | Yes | No | |
| 10 | 32.9 | M | 25 | 172 | 67 | Yes | No | No | |
| 11 | 23.7 | M | 25 | 187 | 74 | No | No | No | |
| 12 | 16.7 | M | 24 | 187 | 84 | Yes | Yes | No | |
| All group A mean (SD) | 19,5 (5,9) | 50% | 24.5 (1.8) | 177.5 (12.7) | 75.3 (16.4) | 25% | 25% | 17% | |
| B | |||||||||
| 13 | 33.1 | F | 24 | 172 | 65 | No | No | Yes | |
| 14 | 43.2 | M | 23 | 185 | 73 | Yes | Yes | No | |
| 15 | 50.1 | F | 21 | 165 | 65 | Yes | No | No | |
| 16 | 32.8 | F | 21 | 162 | 49 | No | Yes | Yes | |
| 17 | 53.2 | F | 24 | 166 | 85 | No | No | Yes | |
| 18 | 31.9 | M | 23 | 187 | 86 | No | Yes | No | |
| 19 | 38.6 | F | 19 | 170 | 58 | No | No | No | |
| 20 | 31.2 | M | 31 | 176 | 78 | No | No | No | |
| 21 | 52.5 | M | 21 | 165 | 68 | No | Yes | Yes | |
| 22 | 44.8 | M | 25 | 171 | 63 | No | No | No | |
| 23 | 47.3 | M | 22 | 169 | 63 | Yes | Yes | Yes | |
| 24 | 54.9 | M | 23 | 180 | 95 | No | No | Yes | |
| All group B mean (SD) | 42,8 (9,0) | 42% | 23.1 (3.0) | 172.3 (8.1) | 70.7 (13.2) | 25% | 42% | 50% | |
| All 24 mean (SD) | 31,1 (14,0) | 46% | 23.8 (2.5) | 174.9 (10.8) | 73.0 (14.7) | 25% | 33% | 33% | |
F = female, m = male
Spirometric values measured in the two groups and % of predicted values.
| Spirometric measure | Group A | Group B | All | |||
| Mean (SD) | % of pred | Mean (SD) | % of pred | Mean (SD) | % of pred. | |
| FVC, litres | 5.2 (1.3) | 105 | 4.6 (1.0) | 101 | 4.9 (1.2) | 103 |
| FEV1, litres | 4.0 (0.8) | 95 | 3.9 (0.8) | 102 | 4.0 (0.8) | 99 |
| FEV% | 79.0 (8.8) | n.a. | 86.2 (3.6) | n.a | 82.6 (7.5) | n.a. |
| PEF litres/min | 570 (112) | 103 | 550 (126) | 106 | 560 (117) | 104 |
| FEF25 litres/sec. | 7.0 (1.6) | 88 | 7.7 (1.7) | 104 | 7.4 (1.7) | 96 |
| FEF50 litres/sec | 4.3 (0.8) | 78 | 5.2 (1.1) | 102 | 4.8 (1.0) | 91 |
| FEF75 litres/sec | 1.9 (0.3) | 73 | 2.2 (0.5) | 92 | 2.1 (0.5) | 84 |
| FET seconds | 5.1 (1.1) | n.a. | 3.9 (1.2) | n.a. | 4.5 (1.3) | n.a. |
n.a. = not applicable
Percentual changes in spirometric values at different points in time in the groups and during periods with (E) and without (B) exposure to cooking fumes.
| Spirometric measure | Group A (n = 12) | Group B (n = 12) | All (n = 24) | |||||||
| 2-1# | 3-1 | 4-1 | 2-1 | 3-1 | 4-1 | 2-1 | 3-1 | 4-1 | ||
| FVC | B | -1.1 | -0.6 | +0.1 | -1.7 | -1.3 | -2.3 | -1.4 | -0.9 | -1.1 |
| E | +0.2 | -0.5 | -0.8 | -1.3 | -0.9 | +0.1 | -0.6 | -0.7 | -0.4 | |
| FEV1 | B | +1.1 | +1.3 | +0.6 | -0.8 | -0.6 | -1.6 | +0.2 | +0.4 | -0.5 |
| E | +0.5 | -0.5 | -1.2 | -0.8 | -0.5 | -0.5 | -0.2 | -0.5 | -0.9 | |
| FEV% | B | +2.3 | +1.9 | +0.6 | +0.9 | +0.8 | +0.7 | +1.6 | +1.4 | +0.7 |
| E | +0.3 | +0.0 | -0.3 | +0.5 | +0.5 | -0.6 | +0.4 | +0.2 | -0.5 | |
| PEF | B | +2.4 | -0.5 | -1.7 | -1.7 | -1.7 | -3.0 | +0.4 | -1.1 | -2.3 |
| E | -0.8 | -0.2 | -0.6 | +0.9 | +2.6 | +1.4 | +0.1 | +1.2 | +0.4 | |
| FEF25 | B | +3.8 | +5.9 | +3.6 | -5.0 | -5.4 | -4.2 | -0.6 | +0.3 | -0.3 |
| E | -0.9 | +0.5 | -0.4 | -1.4 | +1.9* | +0.7 | -1.2 | +1.2 | +0.1 | |
| FEF50 | B | +0.6 | +3.4 | -0.2 | -2.6 | -4.5 | -4.6 | -1.0 | -0.6 | -2.4 |
| E | -0.6 | +0.7 | -2.5 | +6.5* | +6.1* | +0.6 | +2.9 | +3.4 | -1.0 | |
| FEF75 | B | -0.7 | +3.7 | -0.9 | +3.8 | +3.8 | +0.1 | +1.6 | +3.7 | -0.4 |
| E | +2.3 | +0.6 | +0.9 | +1.3 | -1.0 | -0.6 | +1.8 | -0.2 | +0.1 | |
| FET | B | +1.0 | +0.2 | -4.5 | -0.7 | -6.7 | +8.7 | +0.1 | -3.2 | +2.1 |
| E | +1.0 | +16.9 | +1.0 | +12.8 | +14.6 | +7.3 | +6.9 | +15.7* | +4.2 | |
* p < 0.05
# 2-1 is the difference between the first measurement and the measurement at the time of leaving the kitchen after 2 or 4 hours. 3-1 is the difference between the first measurement and the measurement taken 6 hours after entering the kitchen. 4-1 is the difference between the first measurement and the measurement taken 24 hours after entering the kitchen during the day with exposure compared to the day without exposure.
Figure 1Development of selected spirometric varaiables from 1) Just before entering the model kitchen, 2) When leaving it after 2 (group A) or 4 (group B) hours, 3) Six hours after entering, and 4) 24 hours after entering (next morning).