Literature DB >> 18171402

Spirometric and anthropometric determinants of forced expiratory time in a general population.

Annette Kainu1, Ari Lindqvist, Seppo Sarna, Anssi Sovijärvi.   

Abstract

BACKGROUND: Forced expiratory time (FET) has gained new interest in the joint recommendation of the American Thoracic Society (ATS) and the European Respiratory Society (ERS) for the assessment of spirometry. Interpretation of FET is, however, difficult as limited information is available on spirometric and anthropometric determinants of FET in populations.
METHODS: We studied a non-selected population sample including healthy non-smokers with a structured interview and flow-volume spirometry. Regular medication, if any, was continued. Spirometry of 603 individuals (248 men, 355 women) fulfilled predefined quality criteria based on modified ATS recommendations. FET from the flow-volume curve with the largest sum of forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) was used in analyses.
RESULTS: The mean FET in the population sample was 10.7 (95% CI 10.4-11.1) s and in healthy non-smokers 9.8 (9.2-10.4) s. Men had on average longer FET (11.3 s versus 10.3 s), but the gender difference was not significant when FEV1/FVC was used as a covariate. FEV1/FVC (r = -0.613, P<0.01) and maximal mid-expiratory flow (MMEF) correlated negatively and age (r = 0.279, P<0.01), body mass index (BMI) and smoking pack-years positively with FET.
CONCLUSIONS: The findings indicate that mean FET is around 11 s in a non-selected adult population and around 10 s in healthy non-smokers. FET increases slightly with age and BMI, suggesting age- and weight-related changes in pulmonary mechanics. The negative correlation of FET with FEV1/FVC and MMEF even in healthy non-smokers indicates that airflow limitation, either pathological or physiological, tends to prolong FET.

Entities:  

Mesh:

Year:  2008        PMID: 18171402     DOI: 10.1111/j.1475-097X.2007.00771.x

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  4 in total

1.  Ventilatory function in breath-hold divers: effect of glossopharyngeal insufflation.

Authors:  Frederic Lemaître; Eric Clua; Bernard Andréani; Ingrid Castres; Didier Chollet
Journal:  Eur J Appl Physiol       Date:  2010-03       Impact factor: 3.078

2.  Forced expiratory time: a composite of airway narrowing and airway closure.

Authors:  Gwen S Skloot; Kieley L O'Connor-Chapman; Clyde B Schechter; Daniel J Markley; Jason H T Bates
Journal:  J Appl Physiol (1985)       Date:  2020-10-22

3.  Evaluation of spirometry values in relation to beta-2-adrenergic receptor gene polymorphism.

Authors:  Iwona Poziomkowska-Gesicka; E Dzieciolowska-Baran; A Gawlikowska-Sroka; D Slowik-Zylka; T Sroczynski
Journal:  Eur J Med Res       Date:  2010-11-04       Impact factor: 2.175

4.  Short term exposure to cooking fumes and pulmonary function.

Authors:  Sindre Svedahl; Kristin Svendsen; Torgunn Qvenild; Ann Kristin Sjaastad; Bjørn Hilt
Journal:  J Occup Med Toxicol       Date:  2009-05-04       Impact factor: 2.646

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.