The relationship between diurnal variations in intraocular pressure measurements and central corneal thickness and corneal hysteresis.

Aachal Kotecha1, David P Crabb, Alexander Spratt, David F Garway-Heath.   

Abstract

PURPOSE: To examine the relationship between office-hour changes in IOP, measured with the Goldmann applanation tonometer (GAT) and dynamic contour tonometer (DCT), and the corneal characteristics central corneal thickness (CCT) and corneal hysteresis (CH).
METHODS: Sixty-two eyes of 62 untreated normal subjects and patients with untreated glaucoma had IOP measurements performed with the GAT (mm Hg) and DCT (mm Hg) over an 8-hour period at 2-hour intervals beginning at 9 AM. CCT (micrometers) was measured using a noncontact optical low-coherence reflectometry (OLCR) pachymeter, and CH (mm Hg) was measured with an ocular response analyzer (ORA). The associations between IOP measurements and corneal characteristics for each patient over the measurement period were assessed by using multilevel modeling.
RESULTS: GAT and DCT IOP and CCT changed significantly during office hours (ANOVA; GAT: F = 19.9, P < 0.001; DCT: F = 4.6, P = 0.001; CCT: F = 16.4; P < 0.001). No significant changes were observed in CH (ANOVA; F = 1.8, P = 0.13). Multilevel modeling analysis of the interrelationships between CCT, CH, and age on IOP measurements revealed that both CCT and CH changes were significantly associated with GAT IOP changes (GAT IOP/CCT slope, 0.04 mm Hg/microm; 95% confidence intervals [CIs], 0.02-0.06; GAT IOP/CH slope, 0.20 mm Hg/mm Hg; 95% CI, 0.01-0.39). CCT, but not CH, changes were significantly associated with DCT IOP changes (DCT IOP/CCT slope, 0.03 mm Hg/microm; 95% CI, 0.00-0.05). However, although the association between CCT and GAT IOP was relatively uniform between subjects, association between CCT and DCT IOP showed greater intersubject variability. Age had no effect on the diurnal variation of IOP measured with either device.
CONCLUSIONS: Measured IOP and corneal characteristics covary during office hours. Changes in CCT and CH are associated with changes in GAT IOP and, less consistently, with DCT IOP. The data suggest that variations in corneal characteristics explain a small proportion of the change in IOP measurements made with the GAT during office hours.

Entities:  

Mesh:

Year:  2009        PMID: 19407025     DOI: 10.1167/iovs.08-2955

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  21 in total

1.  Diurnal variations of central corneal thickness and intraocular pressure in dogs from 8:00 am to 8:00 pm.

Authors:  Eva Martín-Suárez; Carolina Molleda; Rodrigo Tardón; Alba Galán; José Gallardo; José Molleda
Journal:  Can Vet J       Date:  2014-04       Impact factor: 1.008

2.  Association between corneal biomechanical properties and glaucoma severity.

Authors:  Kaweh Mansouri; Mauro T Leite; Robert N Weinreb; Ali Tafreshi; Linda M Zangwill; Felipe A Medeiros
Journal:  Am J Ophthalmol       Date:  2011-10-21       Impact factor: 5.258

3.  Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT.

Authors:  David Kuerten; Niklas Plange; Eva Charlotte Koch; Antonis Koutsonas; Peter Walter; Matthias Fuest
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-04-21       Impact factor: 3.117

4.  Clinical evaluation of multiparameter correction equations for Goldmann applanation tonometry.

Authors:  P G Davey; A Elsheikh; D F Garway-Heath
Journal:  Eye (Lond)       Date:  2013-03-15       Impact factor: 3.775

5.  Distribution of intraocular pressure and its determinants in an Iranian adult population.

Authors:  Hassan Hashemi; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Abbasali Yekta; Akbar Fotouhi
Journal:  Int J Ophthalmol       Date:  2016-08-18       Impact factor: 1.779

6.  Reproducibility of Central Corneal Thickness Measurements in Healthy and Glaucomatous Eyes.

Authors:  Tony Realini; Matthew J Gurka; Robert N Weinreb
Journal:  J Glaucoma       Date:  2017-09       Impact factor: 2.503

7.  Circadian intraocular pressure profiles in chronic open angle glaucomas.

Authors:  Jost B Jonas; Wido M Budde; Andrea Stroux; Isabel M Oberacher-Velten; Anselm G Juenemann
Journal:  J Ophthalmic Vis Res       Date:  2010-04

8.  Melatonin Adjusts the Phase of Mouse Circadian Clocks in the Cornea Both Ex Vivo and In Vivo.

Authors:  Alex V Huynh; Ethan D Buhr
Journal:  J Biol Rhythms       Date:  2021-07-29       Impact factor: 3.182

9.  Comparison of central corneal thickness measurements using ultrasound pachymetry, ultrasound biomicroscopy, and the Artemis-2 VHF scanner in normal eyes.

Authors:  Haya M Al-Farhan; Wafa'a Majed Al-Otaibi
Journal:  Clin Ophthalmol       Date:  2012-07-06

10.  Diurnal Variation of Retinal Vessel Density in Healthy Human Eyes.

Authors:  Jo-Hsuan Wu; Rafaella C Penteado; Sasan Moghimi; Linda M Zangwill; James A Proudfoot; Robert N Weinreb
Journal:  J Glaucoma       Date:  2021-09-01       Impact factor: 2.290

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.