Literature DB >> 19404170

Stress fracture of bilateral posterior facet after insertion of interspinous implant.

Kook Jin Chung1, Yoon Sub Hwang, Sung Hye Koh.   

Abstract

STUDY
DESIGN: A case report of stress fracture of bilateral lumbar posterior facet after implantation of interspinous process device is reported and the literature reviewed. OBJECTIVE.: To report the rare case of stress fracture of bilateral lumbar posterior facet after implantation of interspinous process device. SUMMARY OF BACKGROUND DATA: A 64-year-old woman presented with severe back pain and radiating pain in both legs. In her history, she had undergone implantation of L4-L5 interspinous process device (Coflex, Paradigm Spine, Wurmlingen, Germany) for her neurogenic claudication at 6 years ago. Magnetic resonance image demonstrated signal change suggesting bilateral L4 inferior process. To the best of the authors' knowledge, there has been no report stress fracture of posterior facet after implantation of interspinous process device.
METHODS: This study reviewed the patient's medical record, her imaging studies, and related literatures.
RESULTS: In the reported case, stress fracture of bilateral posterior facet was documented with MRI and confirmed with surgical treatment for the surgical treatment of spinal stenosis. The involved facet joint was at the site affected by previously implanted interspinous process device.
CONCLUSION: Posterior facet fracture can occur as a complication of interspinous process device.

Entities:  

Mesh:

Year:  2009        PMID: 19404170     DOI: 10.1097/BRS.0b013e31819fd3a0

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  10 in total

Review 1.  Role of lumbar interspinous distraction on the neural elements.

Authors:  Alex Alfieri; Roberto Gazzeri; Julian Prell; Christian Scheller; Jens Rachinger; Christian Strauss; Andreas Schwarz
Journal:  Neurosurg Rev       Date:  2012-05-02       Impact factor: 3.042

2.  [Treatment of dynamic spinal canal stenosis with an interspinous spacer].

Authors:  Christoph J Siepe; Franziska Heider; Rudolf Beisse; H Michael Mayer; Andreas Korge
Journal:  Oper Orthop Traumatol       Date:  2010-11       Impact factor: 1.154

3.  ISASS Recommendations/Coverage Criteria for Decompression with Interlaminar Stabilization - Coverage Indications, Limitations, and/or Medical Necessity.

Authors:  Richard Guyer; Michael Musacchio; Frank P Cammisa; Morgan P Lorio
Journal:  Int J Spine Surg       Date:  2016-12-05

4.  Interspinous posterior devices: What is the real surgical indication?

Authors:  Alessandro Landi
Journal:  World J Clin Cases       Date:  2014-09-16       Impact factor: 1.337

5.  Biomechanical analysis of a new lumbar interspinous device with optimized topology.

Authors:  Chen-Sheng Chen; Shih-Liang Shih
Journal:  Med Biol Eng Comput       Date:  2018-01-06       Impact factor: 2.602

6.  Clinical evaluation of the preliminary safety and effectiveness of a minimally invasive interspinous process device APERIUS(®) in degenerative lumbar spinal stenosis with symptomatic neurogenic intermittent claudication.

Authors:  Jan Van Meirhaeghe; Patrick Fransen; Daniele Morelli; Niall J A Craig; Gregor Godde; Attila Mihalyi; Frederic Collignon
Journal:  Eur Spine J       Date:  2012-05-08       Impact factor: 3.134

7.  Bone resorption during the first year after implantation of a single-segment dynamic interspinous stabilization device and its risk factors.

Authors:  Kaifeng Wang; Zhenqi Zhu; Bo Wang; Yi Zhu; Haiying Liu
Journal:  BMC Musculoskelet Disord       Date:  2015-05-14       Impact factor: 2.362

8.  Finite element analysis of the biomechanical effect of coflex™ on the lumbar spine.

Authors:  Dong-Hak Byun; Dong Ah Shin; Jin-Myung Kim; So-Hee Kim; Hyoung-Ihl Kim
Journal:  Korean J Spine       Date:  2012-09-30

9.  Three-Dimensional Volumetric Changes and Clinical Outcomes after Decompression with DIAM™ Implantation in Patients with Degenerative Lumbar Spine Diseases.

Authors:  Cheng-Yu Li; Mao-Yu Chen; Chen-Nen Chang; Jiun-Lin Yan
Journal:  Medicina (Kaunas)       Date:  2020-12-21       Impact factor: 2.430

10.  One-year follow-up of a series of 100 patients treated for lumbar spinal canal stenosis by means of HeliFix interspinous process decompression device.

Authors:  Alberto Alexandre; Andrea Maria Alexandre; Mario De Pretto; Luca Corò; Raul Saggini
Journal:  Biomed Res Int       Date:  2014-04-15       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.