Literature DB >> 19402723

Polymeric membrane electrodes with high nitrite selectivity based on rhodium(III) porphyrins and salophens as ionophores.

Mariusz Pietrzak1, Mark E Meyerhoff.   

Abstract

Several porphyrin and salophen complexes with Rh(III) are examined as ionophores to prepare nitrite selective polymeric membrane electrodes. All ionophores tested exhibit preferred selectivity toward nitrite anion. Enhanced potentiometric nitrite selectivity is observed in the presence of either lipophilic anionic as well as cationic sites within the membranes, suggesting that the ionophores can function via either a charged or a neutral carrier response mechanism. Among a range of complexes and membrane formulations examined, optimal nitrite selectivity and reversible response down to 5 x 10(-6) M is achieved using Rh(III)-tetra(t-butylphenylporphyrin) as the ionophore in the presence of lipophilic cationic sites in plasticized poly(vinyl chloride) membrane. Response times are substantially longer than typical membrane electrodes apparently because of a slow nitrite ligation reaction with Rh(III); however, a significant improvement in dynamic EMF response can be realized by optimizing the membrane formulation and increasing the temperature. The selectivity observed with these membranes is greater than the best nitrite selective electrodes reported to date in the literature based on lipophilic Co(III)-corrin complexes, allowing the new nitrite electrodes to be utilized to determine the level of nitrite in meats with good correlation to the colorimetric Griess assay method.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19402723      PMCID: PMC2738979          DOI: 10.1021/ac900092f

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  15 in total

Review 1.  Selectivity of potentiometric ion sensors.

Authors:  E Bakker; E Pretsch; P Bühlmann
Journal:  Anal Chem       Date:  2000-03-15       Impact factor: 6.986

2.  Tracing the history of selective ion sensors.

Authors:  R P Buck; E Lindner
Journal:  Anal Chem       Date:  2001-02-01       Impact factor: 6.986

3.  Detection and determination of nitrate and nitrite: a review.

Authors:  M J Moorcroft; J Davis; R G Compton
Journal:  Talanta       Date:  2001-06-21       Impact factor: 6.057

4.  Interference of ascorbic and isoascorbic acids in the spectrophotometric determination of nitrite by the diazotization-coupling technique.

Authors:  G Norwitz; P N Keliher
Journal:  Analyst       Date:  1987-06       Impact factor: 4.616

5.  Synthesis and characterization of Rhodium(III) dichloro complexes with unsymmetrically bound salen-type ligands.

Authors:  R A Stinziano-Eveland; S T Nguyen; L M Liable-Sands; A L Rheingold
Journal:  Inorg Chem       Date:  2000-06-12       Impact factor: 5.165

6.  Protective role of nitric oxide in a model of thrombotic microangiopathy in rats.

Authors:  Jing Shao; Toshio Miyata; Koei Yamada; Norio Hanafusa; Takehiko Wada; Katherine L Gordon; Reiko Inagi; Kiyoshi Kurokawa; Toshiro Fujita; Richard J Johnson; Masaomi Nangaku
Journal:  J Am Soc Nephrol       Date:  2001-10       Impact factor: 10.121

Review 7.  Inhibitors of endogenous nitrosation. Mechanisms and implications in human cancer prevention.

Authors:  H Bartsch; H Ohshima; B Pignatelli
Journal:  Mutat Res       Date:  1988-12       Impact factor: 2.433

8.  Enzymic method for the determination of nitrite in meat and fish products.

Authors:  T Hamano; Y Mitsuhashi; N Aoki; M Semma; Y Ito; Y Oji
Journal:  Analyst       Date:  1998-05       Impact factor: 4.616

9.  Catalytic generation of nitric oxide from nitrite at the interface of polymeric films doped with lipophilic CuII-complex: a potential route to the preparation of thromboresistant coatings.

Authors:  Bong Kyun Oh; Mark E Meyerhoff
Journal:  Biomaterials       Date:  2004-01       Impact factor: 12.479

10.  Nitrosamine, nitrate and nitrite in relation to gastric cancer: a case-control study in Marseille, France.

Authors:  D Pobel; E Riboli; J Cornée; B Hémon; M Guyader
Journal:  Eur J Epidemiol       Date:  1995-02       Impact factor: 8.082

View more
  4 in total

1.  Polymeric optical sensors for selective and sensitive nitrite detection using cobalt(III) corrole and rhodium(III) porphyrin as ionophores.

Authors:  Si Yang; Yaqi Wo; Mark E Meyerhoff
Journal:  Anal Chim Acta       Date:  2014-06-26       Impact factor: 6.558

Review 2.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2010-06-15       Impact factor: 6.986

3.  Carbon quantum dot-based fluorometric nitrite assay by exploiting the oxidation of iron(II) to iron(III).

Authors:  Yingnan Liu; Hanyue Xue; Jinghan Liu; Qinzhi Wang; Li Wang
Journal:  Mikrochim Acta       Date:  2018-01-25       Impact factor: 5.833

4.  Study of Cobalt(III) Corrole as the Neutral Ionophore for Nitrite and Nitrate Detection via Polymeric Membrane Electrodes.

Authors:  Si Yang; Mark E Meyerhoff
Journal:  Electroanalysis       Date:  2013-12-01       Impact factor: 3.223

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.