Literature DB >> 19395078

Fatigue testing of two porcelain-zirconia all-ceramic crown systems.

P G Coelho1, N R Silva, E A Bonfante, P C Guess, E D Rekow, V P Thompson.   

Abstract

OBJECTIVE: To evaluate the mouth-motion step-stress fatigue behavior of two porcelain-zirconia all-ceramic crown systems.
METHODS: The average dimensions of a mandibular first molar crown were imported into CAD software; a tooth preparation was modeled by reducing proximal walls by 1.5 mm and occlusal surface by 2.0 mm. The CAD-based tooth preparation was made by rapid prototyping and used as a master die to fabricate all-ceramic crowns with 1.0 mm porcelain veneered on 0.5 mm Y-TZP cores (LAVA veneer+LAVA frame, 3M/ESPE, and Vita veneer+CERCON frame, Dentsply). Crowns were cemented on aged (60 days in water) composite (Z100, 3M/ESPE) reproductions of the die. Three crowns from the LAVA group were subjected to single cycle load to failure for stress profile design; remainder subjected to step-stress mouth-motion fatigue (three step-stress profiles). All mechanical testing was performed by sliding a WC indenter of 6.25 mm diameter 0.7 mm lingually down the mesio-distal cusp. Master Weibull curves and reliability for missions of 50,000 cycles at 200 N load were calculated (Alta Pro 7, Reliasoft).
RESULTS: Single load to failure showed fractures through the zirconia core. Reliability for a 200 N x 50K cycle mission was not significantly different between systems. In fatigue, failure occurred by formation of large chips within the veneer originating from the contact area without core exposure.
CONCLUSIONS: LAVA and CERCON ceramic systems present similar fatigue behavior; fatigue loading of both systems reproduces clinically observed failure modes.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19395078     DOI: 10.1016/j.dental.2009.03.009

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  23 in total

1.  Confocal Raman microscopy and SEM/EDS investigations of the interface between the zirconia core and veneering ceramic: the influence of a liner and regeneration firing.

Authors:  Jean-Cédric Durand; Bruno Jacquot; Hamideh Salehi; Jacques Margerit; Frédéric J G Cuisinier
Journal:  J Mater Sci Mater Med       Date:  2012-03-24       Impact factor: 3.896

2.  Modified Y-TZP core design improves all-ceramic crown reliability.

Authors:  N R F A Silva; E A Bonfante; B T Rafferty; R A Zavanelli; E D Rekow; V P Thompson; P G Coelho
Journal:  J Dent Res       Date:  2010-11-05       Impact factor: 6.116

3.  Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns.

Authors:  Verena Preis; Thomas Dowerk; Michael Behr; Carola Kolbeck; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2013-07-12       Impact factor: 3.573

4.  On the interfacial fracture of porcelain/zirconia and graded zirconia dental structures.

Authors:  Herzl Chai; James J-W Lee; Adam J Mieleszko; Stephen J Chu; Yu Zhang
Journal:  Acta Biomater       Date:  2014-04-24       Impact factor: 8.947

Review 5.  Performance of dental ceramics: challenges for improvements.

Authors:  E D Rekow; N R F A Silva; P G Coelho; Y Zhang; P Guess; V P Thompson
Journal:  J Dent Res       Date:  2011-01-11       Impact factor: 6.116

6.  Reliability of reduced-thickness and thinly veneered lithium disilicate crowns.

Authors:  N R F A Silva; E A Bonfante; L M Martins; G B Valverde; V P Thompson; J L Ferencz; P G Coelho
Journal:  J Dent Res       Date:  2011-12-28       Impact factor: 6.116

7.  Reliability evaluation of alumina-blasted/acid-etched versus laser-sintered dental implants.

Authors:  Erika O Almeida; Amilcar C Freitas Júnior; Estevam A Bonfante; Nelson R F A Silva; Paulo G Coelho
Journal:  Lasers Med Sci       Date:  2012-07-28       Impact factor: 3.161

8.  Monolithic and bi-layer CAD/CAM lithium-disilicate versus metal-ceramic fixed dental prostheses: comparison of fracture loads and failure modes after fatigue.

Authors:  Stefan Schultheis; Joerg R Strub; Thomas A Gerds; Petra C Guess
Journal:  Clin Oral Investig       Date:  2012-09-22       Impact factor: 3.573

9.  Fatigue resistance of CAD/CAM resin composite molar crowns.

Authors:  Fatma A Shembish; Hui Tong; Marina Kaizer; Malvin N Janal; Van P Thompson; Niek J Opdam; Yu Zhang
Journal:  Dent Mater       Date:  2016-01-08       Impact factor: 5.304

10.  Design features of a three-dimensional molar crown and related maximum principal stress. A finite element model study.

Authors:  Brian T Rafferty; Malvin N Janal; Ricardo A Zavanelli; Nelson R F A Silva; E Dianne Rekow; Van P Thompson; Paulo G Coelho
Journal:  Dent Mater       Date:  2009-10-25       Impact factor: 5.304

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.