Thickness measurements of donor posterior disks after descemet stripping endothelial keratoplasty with anterior segment optical coherence tomography.

Carla P Nieuwendaal1, Mirjam E J van Velthoven, Carine Biallosterski, Ivanka J E van der Meulen, Ruth Lapid-Gortzak, Gerrit R J Melles, Frank D Verbraak.   

Abstract

PURPOSE: To evaluate donor posterior disk thickness measured with anterior segment optical coherence tomography after Descemet stripping endothelial keratoplasty.
METHODS: Fifteen patients (17 eyes) after Descemet stripping endothelial keratoplasty, using manually dissected donor posterior disks, were measured with the Visante anterior segment optical coherence tomography (Carl Zeiss Meditec Inc, Dublin, CA). Optical coherence tomography scans were made in a radial pattern, 45 degrees apart, starting in the horizontal axis. Thickness measurements of the donor posterior disks were taken centrally and at fixed radii toward the periphery and were correlated to postoperative change in spherical equivalent (SE), best-corrected visual acuity (BCVA, in Snellen), and improvement in BCVA.
RESULTS: Median BCVA was 20/30 (range 20/60-20/20) postoperatively. Median postoperative improvement in BCVA was 4 lines (range 1-11). Median follow-up time was 15.5 months (range 6-32 months). Median postoperative change in SE was -0.25 diopters (range -4.25 to +3.00 diopters). Median central disk thickness was 128.3 microm (range 55-181 microm) and increased significantly toward the periphery: median disk thickness at the 1.5 mm radius was 140.8 microm (range 72-199 microm) and at the 3.0 mm radius was 161.5 microm (range 102-245 microm). No correlation was found between (central) donor disk thickness and postoperative BCVA or change in SE. A nonstatistically significant trend was seen toward more improvement in BCVA with thinner donor disks.
CONCLUSIONS: Optical coherence tomography measurements of the manually dissected donor posterior disk showed significant variation in thickness, without a statistically significant effect on postoperative BCVA or improvement thereof. Central thickness varied significantly from the peripheral thickness within donor posterior disk.

Entities:  

Mesh:

Year:  2009        PMID: 19387231     DOI: 10.1097/ICO.0b013e318189135f

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  9 in total

1.  Thinning rate over 24 months in ultrathin DSAEK.

Authors:  Matthew T Fenech; Giulia Coco; Luca Pagano; Kunal A Gadhvi; Mitchell Titley; Hannah J Levis; Mohit Parekh; Stephen B Kaye; Vito Romano
Journal:  Eye (Lond)       Date:  2022-03-15       Impact factor: 4.456

2.  Post-DSAEK optical changes: a comprehensive prospective analysis on the role of ocular wavefront aberrations, haze, and corneal thickness.

Authors:  Holly B Hindman; Krystel R Huxlin; Seth M Pantanelli; Christine L Callan; Ramkumar Sabesan; Steven S T Ching; Brooke E Miller; Tim Martin; Geunyoung Yoon
Journal:  Cornea       Date:  2013-12       Impact factor: 2.651

3.  [Influence of donor lamella thickness on visual acuity after Descemet's stripping automated endothelial keratoplasty (DSAEK)].

Authors:  A-K B Maier; E Gundlach; M K J Klamann; J Gonnermann; E Bertelmann; A M Joussen; N Torun; P W Rieck
Journal:  Ophthalmologe       Date:  2014-02       Impact factor: 1.059

4.  Double-pass microkeratome technique for ultra-thin graft preparation in Descemet's stripping automated endothelial keratoplasty.

Authors:  Maylon Hsu; Walter L Hereth; Majid Moshirfar
Journal:  Clin Ophthalmol       Date:  2012-03-16

5.  Ophthalmic transplantology: anterior segment of the eye - part I.

Authors:  Małgorzata Nita; Barbara Strzałka-Mrozik; Andrzej Grzybowski; Wanda Romaniuk; Urszula Mazurek
Journal:  Med Sci Monit       Date:  2012-05

6.  The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty.

Authors:  Nursal Melda Yenerel; Raciha Beril Kucumen; Ebru Gorgun
Journal:  Clin Ophthalmol       Date:  2013-07-23

7.  Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty.

Authors:  Sepehr Feizi; Mohammad Ali Javadi
Journal:  J Ophthalmic Vis Res       Date:  2019 Jan-Mar

8.  Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty).

Authors:  Melissa H Y Wong; Annabel Chew; Hla M Htoon; Beng H Lee; Jun Cheng; Jiang Liu; Donald T Tan; Jodhbir S Mehta
Journal:  BMC Med Imaging       Date:  2012-08-01       Impact factor: 1.930

9.  Indications of optical coherence tomography in keratoplasties: literature review.

Authors:  Thiago Trindade Nesi; Daniel Amorim Leite; Fábio Medina Rocha; Marco Antônio Tanure; Pedro Paulo Reis; Eduardo Büchele Rodrigues; Mauro Silveira de Queiroz Campos
Journal:  J Ophthalmol       Date:  2012-10-15       Impact factor: 1.909

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.