Literature DB >> 29876759

Inter-observer variation of hippocampus delineation in hippocampal avoidance prophylactic cranial irradiation.

F Bartel1, M van Herk2, H Vrenken1, F Vandaele3, S Sunaert4, K de Jaeger5, N J Dollekamp6, C Carbaat7, E Lamers7, E M T Dieleman8, Y Lievens9, D de Ruysscher10, S B Schagen11, M B de Ruiter11, J C de Munck1, J Belderbos12.   

Abstract

BACKGROUND: Hippocampal avoidance prophylactic cranial irradiation (HA-PCI) techniques have been developed to reduce radiation damage to the hippocampus. An inter-observer hippocampus delineation analysis was performed and the influence of the delineation variability on dose to the hippocampus was studied.
MATERIALS AND METHODS: For five patients, seven observers delineated both hippocampi on brain MRI. The intra-class correlation (ICC) with absolute agreement and the generalized conformity index (CIgen) were computed. Median surfaces over all observers' delineations were created for each patient and regional outlining differences were analysed. HA-PCI dose plans were made from the median surfaces and we investigated whether dose constraints in the hippocampus could be met for all delineations.
RESULTS: The ICC for the left and right hippocampus was 0.56 and 0.69, respectively, while the CIgen ranged from 0.55 to 0.70. The posterior and anterior-medial hippocampal regions had most variation with SDs ranging from approximately 1 to 2.5 mm. The mean dose (Dmean) constraint was met for all delineations, but for the dose received by 1% of the hippocampal volume (D1%) violations were observed.
CONCLUSION: The relatively low ICC and CIgen indicate that delineation variability among observers for both left and right hippocampus was large. The posterior and anterior-medial border have the largest delineation inaccuracy. The hippocampus Dmean constraint was not violated.

Entities:  

Keywords:  HA-PCI; Hippocampus delineation; Inter-observer variation; SCLC

Mesh:

Year:  2018        PMID: 29876759     DOI: 10.1007/s12094-018-1903-7

Source DB:  PubMed          Journal:  Clin Transl Oncol        ISSN: 1699-048X            Impact factor:   3.405


  51 in total

Review 1.  The human hippocampus and spatial and episodic memory.

Authors:  Neil Burgess; Eleanor A Maguire; John O'Keefe
Journal:  Neuron       Date:  2002-08-15       Impact factor: 17.173

2.  MRI as a biomarker of disease progression in a therapeutic trial of milameline for AD.

Authors:  C R Jack; M Slomkowski; S Gracon; T M Hoover; J P Felmlee; K Stewart; Y Xu; M Shiung; P C O'Brien; R Cha; D Knopman; R C Petersen
Journal:  Neurology       Date:  2003-01-28       Impact factor: 9.910

Review 3.  Prophylactic cranial irradiation for patients with lung cancer.

Authors:  Cécile Le Péchoux; Alexander Sun; Ben J Slotman; Dirk De Ruysscher; José Belderbos; Elizabeth M Gore
Journal:  Lancet Oncol       Date:  2016-07       Impact factor: 41.316

4.  Preservation of memory with conformal avoidance of the hippocampal neural stem-cell compartment during whole-brain radiotherapy for brain metastases (RTOG 0933): a phase II multi-institutional trial.

Authors:  Vinai Gondi; Stephanie L Pugh; Wolfgang A Tome; Chip Caine; Ben Corn; Andrew Kanner; Howard Rowley; Vijayananda Kundapur; Albert DeNittis; Jeffrey N Greenspoon; Andre A Konski; Glenn S Bauman; Sunjay Shah; Wenyin Shi; Merideth Wendland; Lisa Kachnic; Minesh P Mehta
Journal:  J Clin Oncol       Date:  2014-10-27       Impact factor: 44.544

5.  Within-subject template estimation for unbiased longitudinal image analysis.

Authors:  Martin Reuter; Nicholas J Schmansky; H Diana Rosas; Bruce Fischl
Journal:  Neuroimage       Date:  2012-03-10       Impact factor: 6.556

6.  Clinical neurological outcome and quality of life among patients with limited small-cell cancer treated with two different doses of prophylactic cranial irradiation in the intergroup phase III trial (PCI99-01, EORTC 22003-08004, RTOG 0212 and IFCT 99-01).

Authors:  C Le Péchoux; A Laplanche; C Faivre-Finn; T Ciuleanu; R Wanders; D Lerouge; R Keus; M Hatton; G M Videtic; S Senan; A Wolfson; R Jones; R Arriagada; E Quoix; A Dunant
Journal:  Ann Oncol       Date:  2010-12-07       Impact factor: 32.976

7.  Prospective Study of Hippocampal-Sparing Prophylactic Cranial Irradiation in Limited-Stage Small Cell Lung Cancer.

Authors:  Kristin J Redmond; Russell K Hales; Heather Anderson-Keightly; Xian C Zhou; Megan Kummerlowe; Haris I Sair; Mario Duhon; Lawrence Kleinberg; Gary L Rosner; Tracy Vannorsdall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-03-14       Impact factor: 7.038

8.  A comparison of methods for the automated calculation of volumes and atrophy rates in the hippocampus.

Authors:  J Barnes; J Foster; R G Boyes; T Pepple; E K Moore; J M Schott; C Frost; R I Scahill; N C Fox
Journal:  Neuroimage       Date:  2008-01-26       Impact factor: 6.556

9.  The Alzheimer's Disease Neuroimaging Initiative (ADNI): MRI methods.

Authors:  Clifford R Jack; Matt A Bernstein; Nick C Fox; Paul Thompson; Gene Alexander; Danielle Harvey; Bret Borowski; Paula J Britson; Jennifer L Whitwell; Chadwick Ward; Anders M Dale; Joel P Felmlee; Jeffrey L Gunter; Derek L G Hill; Ron Killiany; Norbert Schuff; Sabrina Fox-Bosetti; Chen Lin; Colin Studholme; Charles S DeCarli; Gunnar Krueger; Heidi A Ward; Gregory J Metzger; Katherine T Scott; Richard Mallozzi; Daniel Blezek; Joshua Levy; Josef P Debbins; Adam S Fleisher; Marilyn Albert; Robert Green; George Bartzokis; Gary Glover; John Mugler; Michael W Weiner
Journal:  J Magn Reson Imaging       Date:  2008-04       Impact factor: 4.813

10.  Comparing manual and automatic segmentation of hippocampal volumes: reliability and validity issues in younger and older brains.

Authors:  Elisabeth Wenger; Johan Mårtensson; Hannes Noack; Nils Christian Bodammer; Simone Kühn; Sabine Schaefer; Hans-Jochen Heinze; Emrah Düzel; Lars Bäckman; Ulman Lindenberger; Martin Lövdén
Journal:  Hum Brain Mapp       Date:  2014-02-14       Impact factor: 5.038

View more
  3 in total

Review 1.  Treatment planning for proton therapy: what is needed in the next 10 years?

Authors:  Hakan Nystrom; Maria Fuglsang Jensen; Petra Witt Nystrom
Journal:  Br J Radiol       Date:  2019-08-07       Impact factor: 3.039

2.  The Learning Curve and Inter-Observer Variability in Contouring the Hippocampus under the Hippocampal Sparing Guidelines of Radiation Therapy Oncology Group 0933.

Authors:  Monika Konopka-Filippow; Ewa Sierko; Dominika Hempel; Rafał Maksim; Natalia Samołyk-Kogaczewska; Tomasz Filipowski; Ewa Rożkowska; Stefan Jelski; Beata Kasprowicz; Eryka Karbowska; Krzysztof Szymański; Kamil Szczecina
Journal:  Curr Oncol       Date:  2022-04-08       Impact factor: 3.109

3.  Automated contouring and planning pipeline for hippocampal-avoidant whole-brain radiotherapy.

Authors:  Christine H Feng; Mariel Cornell; Kevin L Moore; Roshan Karunamuni; Tyler M Seibert
Journal:  Radiat Oncol       Date:  2020-10-30       Impact factor: 3.481

  3 in total