Literature DB >> 19374710

Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.

Xi Ding1, Xing-Hao Zhu, Sheng-Hui Liao, Xiu-Hua Zhang, Hong Chen.   

Abstract

PURPOSE: To establish a 3D finite element model of a mandible with dental implants for immediate loading and to analyze stress distribution in bone around implants of different diameters.
MATERIALS AND METHODS: Three mandible models, embedded with thread implants (ITI, Straumann, Switzerland) with diameters of 3.3, 4.1, and 4.8 mm, respectively, were developed using CT scanning and self-developed Universal Surgical Integration System software. The von Mises stress and strain of the implant-bone interface were calculated with the ANSYS software when implants were loaded with 150 N vertical or buccolingual forces.
RESULTS: When the implants were loaded with vertical force, the von Mises stress concentrated on the mesial and distal surfaces of cortical bone around the neck of implants, with peak values of 25.0, 17.6 and 11.6 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains (5854, 4903, 4344 muepsilon) were located on the buccal cancellous bone around the implant bottom and threads of implants. The stress and strain were significantly lower (p < 0.05) with the increased diameter of implant. When the implants were loaded with buccolingual force, the peak von Mises stress values occurred on the buccal surface of cortical bone around the implant neck, with values of 131.1, 78.7, and 68.1 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains occurred on the buccal surface of cancellous bone adjacent to the implant neck, with peak values of 14,218, 12,706, and 11,504 microm, respectively. The stress of the 4.1-mm diameter implants was significantly lower (p < 0.05) than those of 3.3-mm diameter implants, but not statistically different from that of the 4.8 mm implant.
CONCLUSIONS: With an increase of implant diameter, stress and strain on the implant-bone interfaces significantly decreased, especially when the diameter increased from 3.3 to 4.1 mm. It appears that dental implants of 10 mm in length for immediate loading should be at least 4.1 mm in diameter, and uniaxial loading to dental implants should be avoided or minimized.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19374710     DOI: 10.1111/j.1532-849X.2009.00453.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  11 in total

1.  [Influence of thread shapes of custommade root-analogue implants on stress distribution of peri-implant bone: A three-dimensional finite element analysis].

Authors:  C P Lin; S H Lu; J X Zhu; H C Hu; Z G Yue; Z H Tang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-12-18

2.  Biomechanical evaluations of the long-term stability of dental implant using finite element modeling method: a systematic review.

Authors:  Seyed Aref Hosseini-Faradonbeh; Hamid Reza Katoozian
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

3.  Revealing Localised Mechanochemistry of Biomaterials Using In Situ Multiscale Chemical Analysis.

Authors:  Nicholas T H Farr
Journal:  Materials (Basel)       Date:  2022-05-11       Impact factor: 3.748

4.  Association between implant apex and sinus floor in posterior maxilla dental implantation: A three-dimensional finite element analysis.

Authors:  Xu Yan; Xinwen Zhang; Weichao Chi; Hongjun Ai; Lin Wu
Journal:  Exp Ther Med       Date:  2015-01-22       Impact factor: 2.447

5.  Influence of thread pitch, helix angle, and compactness on micromotion of immediately loaded implants in three types of bone quality: a three-dimensional finite element analysis.

Authors:  Pan Ma; Wei Xiong; Baosheng Tan; Wei Geng; Jiaqiang Liu; Weihong Li; Dehua Li
Journal:  Biomed Res Int       Date:  2014-07-08       Impact factor: 3.411

6.  Accelerating Corrosion of Pure Magnesium Co-implanted with Titanium in Vivo.

Authors:  Peng Hou; Pei Han; Changli Zhao; Hongliu Wu; Jiahua Ni; Shaoxiang Zhang; Jingyi Liu; Yuanzhuang Zhang; Haidong Xu; Pengfei Cheng; Shen Liu; Yufeng Zheng; Xiaonong Zhang; Yimin Chai
Journal:  Sci Rep       Date:  2017-02-07       Impact factor: 4.379

7.  Comparative Evaluation of Implant Designs: Influence of Diameter, Length, and Taper on Stress and Strain in the Mandibular Segment-A Three-Dimensional Finite Element Analysis.

Authors:  Gowthama Raaj; Pulliappan Manimaran; Chandran Dhinesh Kumar; Duraisamy Sai Sadan; Mathivanan Abirami
Journal:  J Pharm Bioallied Sci       Date:  2019-05

8.  A randomized clinical study to compare implant stability and bone loss using early loading protocol in two implant systems with different design.

Authors:  Rani Ranabhatt; Kamleshwar Singh; Ramashanker Siddharth; Shuchi Tripathi; Deeksha Arya
Journal:  J Indian Prosthodont Soc       Date:  2021 Jan-Mar

9.  Comparison of the Effect of Three Abutment-implant Connections on Stress Distribution at the Internal Surface of Dental Implants: A Finite Element Analysis.

Authors:  Saeed Raoofi; Maryam Khademi; Reza Amid; Mahdi Kadkhodazadeh; Mohammad Reza Movahhedi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2013-08-30

10.  FEM Analysis of Mandibular Prosthetic Overdenture Supported by Dental Implants: Evaluation of Different Retention Methods.

Authors:  M Cicciù; G Cervino; E Bramanti; F Lauritano; G Lo Gudice; L Scappaticci; A Rapparini; E Guglielmino; G Risitano
Journal:  Comput Math Methods Med       Date:  2015-12-21       Impact factor: 2.238

View more