Literature DB >> 19369710

Soft-tissue phase-contrast tomography with an x-ray tube source.

Martin Bech1, Torben H Jensen, Robert Feidenhans'l, Oliver Bunk, Christian David, Franz Pfeiffer.   

Abstract

We report the first experimental soft-tissue phase-contrast tomography results using a conventional x-ray tube source, with a millimeter-sized focal spot. The setup is based on a Talbot-Lau grating interferometer operated at a mean energy of 28 keV. We present three-dimensional ex vivo images of a chicken heart sample, fixated in formalin. The results clearly demonstrate the advantageous contrast attainable through phase-contrast imaging over conventional attenuation-based approaches.

Entities:  

Mesh:

Year:  2009        PMID: 19369710     DOI: 10.1088/0031-9155/54/9/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  28 in total

1.  Small-angle scattering computed tomography (SAS-CT) using a Talbot-Lau interferometerand a rotating anode x-ray tube:theory and experiments.

Authors:  Guang-Hong Chen; Nicholas Bevins; Joseph Zambelli; Zhihua Qi
Journal:  Opt Express       Date:  2010-06-07       Impact factor: 3.894

2.  A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging.

Authors:  Eric E Bennett; Rael Kopace; Ashley F Stein; Han Wen
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

3.  Experimental results from a preclinical X-ray phase-contrast CT scanner.

Authors:  Arne Tapfer; Martin Bech; Astrid Velroyen; Jan Meiser; Jürgen Mohr; Marco Walter; Joachim Schulz; Bart Pauwels; Peter Bruyndonckx; Xuan Liu; Alexander Sasov; Franz Pfeiffer
Journal:  Proc Natl Acad Sci U S A       Date:  2012-09-10       Impact factor: 11.205

4.  Fundamental relationship between the noise properties of grating-based differential phase contrast CT and absorption CT: theoretical framework using a cascaded system model and experimental validation.

Authors:  Ke Li; Nicholas Bevins; Joseph Zambelli; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

5.  3D angioarchitecture changes after spinal cord injury in rats using synchrotron radiation phase-contrast tomography.

Authors:  J Hu; Y Cao; T Wu; D Li; H Lu
Journal:  Spinal Cord       Date:  2015-03-31       Impact factor: 2.772

6.  Accurate micro-computed tomography imaging of pore spaces in collagen-based scaffold.

Authors:  Jan Zidek; Lucy Vojtova; A M Abdel-Mohsen; Jiri Chmelik; Tomas Zikmund; Jana Brtnikova; Roman Jakubicek; Lukas Zubal; Jiri Jan; Jozef Kaiser
Journal:  J Mater Sci Mater Med       Date:  2016-05-06       Impact factor: 3.896

7.  Improved reconstruction of phase-stepping data for Talbot-Lau x-ray imaging.

Authors:  Sebastian Kaeppler; Jens Rieger; Georg Pelzer; Florian Horn; Thilo Michel; Andreas Maier; Gisela Anton; Christian Riess
Journal:  J Med Imaging (Bellingham)       Date:  2017-09-05

8.  Design optimization of a periodic microstructured array anode for hard x-ray grating interferometry.

Authors:  Guibin Zan; David John Vine; Richard Ian Spink; Wenbing Yun; Qiuping Wang; Ge Wang
Journal:  Phys Med Biol       Date:  2019-07-16       Impact factor: 3.609

9.  Fabrication of 200 nanometer period centimeter area hard x-ray absorption gratings by multilayer deposition.

Authors:  S K Lynch; C Liu; N Y Morgan; X Xiao; A A Gomella; D Mazilu; E E Bennett; L Assoufid; F de Carlo; H Wen
Journal:  J Micromech Microeng       Date:  2012-08-23       Impact factor: 1.881

10.  Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: spectrum of noise equivalent quanta NEQ(k).

Authors:  Xiangyang Tang; Yi Yang; Shaojie Tang
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.