Improved reconstruction of phase-stepping data for Talbot-Lau x-ray imaging.

Sebastian Kaeppler1, Jens Rieger2, Georg Pelzer2, Florian Horn2, Thilo Michel2, Andreas Maier1, Gisela Anton2, Christian Riess1.   

Abstract

Grating-based Talbot-Lau x-ray interferometry is a popular method for measuring absorption, phase shift, and small-angle scattering. The standard acquisition method for this modality is phase stepping, where the Talbot pattern is reconstructed from multiple images acquired at different grating positions. We review the implicit assumptions in phase-stepping reconstruction, and find that the assumptions of perfectly known grating positions and homoscedastic noise variance are violated in some scenarios. Additionally, we investigate a recently reported estimation bias in the visibility and dark-field signal. To adapt the phase-stepping reconstruction to these findings, we propose three improvements to the reconstruction. These improvements are (a) to use prior knowledge to compute more accurate grating positions to reduce moiré artifacts, (b) to utilize noise variance information to reduce dark-field and phase noise in high-visibility acquisitions, and (c) to perform correction of an estimation bias in the interferometer visibility, leading to more quantitative dark-field imaging in acquisitions with a low signal-to-noise ratio. We demonstrate the benefit of our methods on simulated data, as well as on images acquired with a Talbot-Lau interferometer.

Keywords:  Talbot–Lau; moiré; phase contrast; phase stepping; reconstruction

Year:  2017        PMID: 28894764      PMCID: PMC5584710          DOI: 10.1117/1.JMI.4.3.034005

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  33 in total

1.  Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping.

Authors:  Nicholas Bevins; Joseph Zambelli; Ke Li; Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Increasing the darkfield contrast-to-noise ratio using a deconvolution-based information retrieval algorithm in X-ray grating-based phase-contrast imaging.

Authors:  Thomas Weber; Georg Pelzer; Florian Bayer; Florian Horn; Jens Rieger; André Ritter; Andrea Zang; Jürgen Durst; Gisela Anton; Thilo Michel
Journal:  Opt Express       Date:  2013-07-29       Impact factor: 3.894

3.  Phase and absorption retrieval using incoherent X-ray sources.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Proc Natl Acad Sci U S A       Date:  2012-08-13       Impact factor: 11.205

4.  Talbot-Lau X-ray phase contrast for tiling-based acquisitions without reference scanning.

Authors:  Sebastian Kaeppler; Maria Seifert; Florian Horn; Georg Pelzer; Jens Rieger; Thilo Michel; Andreas Maier; Gisela Anton; Christian Riess
Journal:  Med Phys       Date:  2017-04-20       Impact factor: 4.071

5.  Reconstruction of scalar and vectorial components in X-ray dark-field tomography.

Authors:  Florian L Bayer; Shiyang Hu; Andreas Maier; Thomas Weber; Gisela Anton; Thilo Michel; Christian P Riess
Journal:  Proc Natl Acad Sci U S A       Date:  2014-08-18       Impact factor: 11.205

6.  Optimisation of image reconstruction for phase-contrast x-ray Talbot-Lau imaging with regard to mechanical robustness.

Authors:  M Seifert; S Kaeppler; C Hauke; F Horn; G Pelzer; J Rieger; T Michel; C Riess; G Anton
Journal:  Phys Med Biol       Date:  2016-08-12       Impact factor: 3.609

7.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

8.  The first analysis and clinical evaluation of native breast tissue using differential phase-contrast mammography.

Authors:  Marco Stampanoni; Zhentian Wang; Thomas Thüring; Christian David; Ewald Roessl; Mafalda Trippel; Rahel A Kubik-Huch; Gad Singer; Michael K Hohl; Nik Hauser
Journal:  Invest Radiol       Date:  2011-12       Impact factor: 6.016

9.  Statistical iterative reconstruction algorithm for X-ray phase-contrast CT.

Authors:  Dieter Hahn; Pierre Thibault; Andreas Fehringer; Martin Bech; Thomas Koehler; Franz Pfeiffer; Peter B Noël
Journal:  Sci Rep       Date:  2015-06-12       Impact factor: 4.379

10.  Helical X-ray phase-contrast computed tomography without phase stepping.

Authors:  M Marschner; M Willner; G Potdevin; A Fehringer; P B Noël; F Pfeiffer; J Herzen
Journal:  Sci Rep       Date:  2016-04-07       Impact factor: 4.379

View more
  1 in total

1.  Implementation of a Talbot-Lau interferometer in a clinical-like c-arm setup: A feasibility study.

Authors:  Florian Horn; Martino Leghissa; Sebastian Kaeppler; Georg Pelzer; Jens Rieger; Maria Seifert; Johannes Wandner; Thomas Weber; Thilo Michel; Christian Riess; Gisela Anton
Journal:  Sci Rep       Date:  2018-02-02       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.