Literature DB >> 19364598

Neurovascular imaging at 1.5 tesla versus 3.0 tesla.

Benjamin Y Huang1, Mauricio Castillo.   

Abstract

The primary advantage of high field strength MR imaging over imaging on modern 1.5 Tesla (T) systems is increased signal-to-noise ratio, which can be used to improve image quality or shorten scan acquisition time. In the years since 3.0T scanners were first approved for clinical use, one of the areas which has benefited greatly from its introduction is neurovascular MR angiography (MRA). Early experience has shown significant improvements in resolution and image quality. Whether high field strength MRA is robust or accurate enough to replace digital subtraction angiography in the foreseeable future remains to be seen. This article discusses the current state of neurovascular MRA at 3.0T, basic physical differences between MR imaging at 1.5T and 3.0T, and their effects on MRA sequences. The literature regarding the efficacy of 3.0T MRA techniques for diagnosing specific neurovascular pathologies and carotid steno occlusive disease is reviewed.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19364598     DOI: 10.1016/j.mric.2008.12.005

Source DB:  PubMed          Journal:  Magn Reson Imaging Clin N Am        ISSN: 1064-9689            Impact factor:   2.266


  7 in total

1.  Comparative analysis of fluorescent angiography, computed tomographic angiography and magnetic resonance angiography for planning autologous breast reconstruction.

Authors:  Michael P Chae; David J Hunter-Smith; Warren Matthew Rozen
Journal:  Gland Surg       Date:  2015-04

2.  Amygdala structure and aggressiveness in borderline personality disorder.

Authors:  Falk Mancke; Sabine C Herpertz; Dusan Hirjak; Rebekka Knies; Katja Bertsch
Journal:  Eur Arch Psychiatry Clin Neurosci       Date:  2016-11-22       Impact factor: 5.270

Review 3.  Magnetic resonance angiography: current status and future directions.

Authors:  Michael P Hartung; Thomas M Grist; Christopher J François
Journal:  J Cardiovasc Magn Reson       Date:  2011-03-09       Impact factor: 5.364

4.  One-stop preoperative assessment of renal vessels for living donors with 3.0 T non-contrast-enhanced magnetic resonance angiography: compared with computerized tomography angiography and surgical results.

Authors:  Xiaotian Li; Fangjie Xia; Lihua Chen; Xiaodong Zhang; Chunbai Mo; Wen Shen
Journal:  Br J Radiol       Date:  2021-10-05       Impact factor: 3.039

5.  Accuracy of 3 T MR angioraphy in vertebral artery stenosis and coincidence with other cerebrovascular stenoses.

Authors:  Hyun Seok Choi; Dong Ik Kim; Dong Joon Kim; Jinna Kim; Eun Soo Kim; Seung-Koo Lee
Journal:  Neuroradiology       Date:  2010-01-28       Impact factor: 2.804

6.  Artificial luminal narrowing on contrast-enhanced magnetic resonance angiograms on an occasion of stent-assisted coiling of intracranial aneurysm: in vitro comparison using two different stents with variable imaging parameters.

Authors:  Jee Hyun Seok; Hyun Seok Choi; So-Lyung Jung; Kook-Jin Ahn; Myeong Jin Kim; Yong Sam Shin; Bum-soo Kim
Journal:  Korean J Radiol       Date:  2012-08-28       Impact factor: 3.500

7.  Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness.

Authors:  Raymond Q Migrino; Mark Bowers; Leanne Harmann; Robert Prost; John F LaDisa
Journal:  J Cardiovasc Magn Reson       Date:  2011-08-03       Impact factor: 5.364

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.