Literature DB >> 19342324

Removal of BCG artifacts using a non-Kirchhoffian overcomplete representation.

Mads Dyrholm, Robin Goldman, Paul Sajda, Truman R Brown.   

Abstract

We present a nonlinear unmixing approach for extracting the ballistocardiogram (BCG) from EEG recorded in an MR scanner during simultaneous acquisition of functional MRI (fMRI). First, an overcomplete basis is identified in the EEG based on a custom multipath EEG electrode cap. Next, the overcomplete basis is used to infer non-Kirchhoffian latent variables that are not consistent with a conservative electric field. Neural activity is strictly Kirchhoffian while the BCG artifact is not, and the representation can hence be used to remove the artifacts from the data in a way that does not attenuate the neural signals needed for optimal single-trial classification performance. We compare our method to more standard methods for BCG removal, namely independent component analysis and optimal basis sets, by looking at single-trial classification performance for an auditory oddball experiment. We show that our overcomplete representation method for removing BCG artifacts results in better single-trial classification performance compared to the conventional approaches, indicating that the derived neural activity in this representation retains the complex information in the trial-to-trial variability.

Entities:  

Mesh:

Year:  2009        PMID: 19342324      PMCID: PMC2665919          DOI: 10.1109/TBME.2008.2005952

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  10 in total

1.  Learning overcomplete representations.

Authors:  M S Lewicki; T J Sejnowski
Journal:  Neural Comput       Date:  2000-02       Impact factor: 2.026

2.  Acquiring simultaneous EEG and functional MRI.

Authors:  R I Goldman; J M Stern; J Engel; M S Cohen
Journal:  Clin Neurophysiol       Date:  2000-11       Impact factor: 3.708

3.  Linear spatial integration for single-trial detection in encephalography.

Authors:  Lucas Parra; Chris Alvino; Akaysha Tang; Barak Pearlmutter; Nick Yeung; Allen Osman; Paul Sajda
Journal:  Neuroimage       Date:  2002-09       Impact factor: 6.556

4.  Motion and ballistocardiogram artifact removal for interleaved recording of EEG and EPs during MRI.

Authors:  Giorgio Bonmassar; Patrick L Purdon; Iiro P Jääskeläinen; Keith Chiappa; Victor Solo; Emery N Brown; John W Belliveau
Journal:  Neuroimage       Date:  2002-08       Impact factor: 6.556

5.  EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis.

Authors:  Arnaud Delorme; Scott Makeig
Journal:  J Neurosci Methods       Date:  2004-03-15       Impact factor: 2.390

6.  Simultaneous recording of laser-evoked brain potentials and continuous, high-field functional magnetic resonance imaging in humans.

Authors:  G D Iannetti; R K Niazy; R G Wise; P Jezzard; J C W Brooks; L Zambreanu; W Vennart; P M Matthews; I Tracey
Journal:  Neuroimage       Date:  2005-08-19       Impact factor: 6.556

7.  ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner.

Authors:  G Srivastava; S Crottaz-Herbette; K M Lau; G H Glover; V Menon
Journal:  Neuroimage       Date:  2005-01-01       Impact factor: 6.556

8.  Removal of FMRI environment artifacts from EEG data using optimal basis sets.

Authors:  R K Niazy; C F Beckmann; G D Iannetti; J M Brady; S M Smith
Journal:  Neuroimage       Date:  2005-09-16       Impact factor: 6.556

9.  The brain's orienting response: An event-related functional magnetic resonance imaging investigation.

Authors:  David Friedman; Robin Goldman; Yaakov Stern; Truman R Brown
Journal:  Hum Brain Mapp       Date:  2009-04       Impact factor: 5.038

10.  Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength.

Authors:  Stefan Debener; Karen J Mullinger; Rami K Niazy; Richard W Bowtell
Journal:  Int J Psychophysiol       Date:  2007-07-12       Impact factor: 2.997

  10 in total
  4 in total

Review 1.  Single-trial analysis of neuroimaging data: inferring neural networks underlying perceptual decision-making in the human brain.

Authors:  Paul Sajda; Marios G Philiastides; Lucas C Parra
Journal:  IEEE Rev Biomed Eng       Date:  2009

2.  Ballistocardiogram artifact removal with a reference layer and standard EEG cap.

Authors:  Qingfei Luo; Xiaoshan Huang; Gary H Glover
Journal:  J Neurosci Methods       Date:  2014-06-22       Impact factor: 2.390

3.  Ballistocardiogram Artifact Reduction in Simultaneous EEG-fMRI Using Deep Learning.

Authors:  James R McIntosh; Jiaang Yao; Linbi Hong; Josef Faller; Paul Sajda
Journal:  IEEE Trans Biomed Eng       Date:  2020-12-21       Impact factor: 4.538

4.  Removing ballistocardiogram (BCG) artifact from full-scalp EEG acquired inside the MR scanner with Orthogonal Matching Pursuit (OMP).

Authors:  Hongjing Xia; Dan Ruan; Mark S Cohen
Journal:  Front Neurosci       Date:  2014-07-29       Impact factor: 4.677

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.