Literature DB >> 17683819

Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength.

Stefan Debener1, Karen J Mullinger, Rami K Niazy, Richard W Bowtell.   

Abstract

Electroencephalogram (EEG) data recorded simultaneously with functional magnetic resonance imaging (fMRI) suffer from severe artefacts. The ballistocardiogram (BCG) artefact in particular is as yet poorly understood and different BCG removal strategies have been proposed. In the present study, EEG data were recorded from four participants in three different MRI scanners with field strengths of 1.5, 3 and 7 T, with the aim of investigating the impact of the static magnetic field strength on the BCG artefact and independent component analysis (ICA). The results confirm that the amplitude of the BCG artefact is a function of the static magnetic field strength. Moreover, the spatial variability of the BCG artefact substantially increased at higher magnetic field strengths. A comparison of ICA before and after channel-wise BCG correction revealed that typical independent components could be more easily identified when ICA was applied after channel-wise BCG correction. Further analysis of EEG and electrocardiogram recordings points towards the contribution of at least two different processes to the origin of the BCG, which are blood movement or axial head rotation on the one hand and electrode movement at lateral sites of the head on the other. This is summarized in a preliminary BCG model that may help to explain recent inconsistencies regarding the usefulness of ICA for BCG removal. It may also guide the future development of more advanced BCG removal procedures.

Entities:  

Mesh:

Year:  2007        PMID: 17683819     DOI: 10.1016/j.ijpsycho.2007.05.015

Source DB:  PubMed          Journal:  Int J Psychophysiol        ISSN: 0167-8760            Impact factor:   2.997


  46 in total

1.  Best current practice for obtaining high quality EEG data during simultaneous FMRI.

Authors:  Karen J Mullinger; Pierluigi Castellone; Richard Bowtell
Journal:  J Vis Exp       Date:  2013-06-03       Impact factor: 1.355

2.  SSVEP signatures of binocular rivalry during simultaneous EEG and fMRI.

Authors:  Keith W Jamison; Abhrajeet V Roy; Sheng He; Stephen A Engel; Bin He
Journal:  J Neurosci Methods       Date:  2015-01-30       Impact factor: 2.390

3.  Reference-free removal of EEG-fMRI ballistocardiogram artifacts with harmonic regression.

Authors:  Pavitra Krishnaswamy; Giorgio Bonmassar; Catherine Poulsen; Eric T Pierce; Patrick L Purdon; Emery N Brown
Journal:  Neuroimage       Date:  2015-07-05       Impact factor: 6.556

4.  Physical modeling of pulse artefact sources in simultaneous EEG/fMRI.

Authors:  Winston X Yan; Karen J Mullinger; Gerda B Geirsdottir; Richard Bowtell
Journal:  Hum Brain Mapp       Date:  2010-04       Impact factor: 5.038

5.  Event-related potential and functional MRI measures of face-selectivity are highly correlated: a simultaneous ERP-fMRI investigation.

Authors:  Boaz Sadeh; Ilana Podlipsky; Andrey Zhdanov; Galit Yovel
Journal:  Hum Brain Mapp       Date:  2010-10       Impact factor: 5.038

6.  The dual facet of gamma oscillations: separate visual and decision making circuits as revealed by simultaneous EEG/fMRI.

Authors:  João Castelhano; Isabel Catarina Duarte; Michael Wibral; Eugénio Rodriguez; Miguel Castelo-Branco
Journal:  Hum Brain Mapp       Date:  2014-05-16       Impact factor: 5.038

7.  Statistical feature extraction for artifact removal from concurrent fMRI-EEG recordings.

Authors:  Zhongming Liu; Jacco A de Zwart; Peter van Gelderen; Li-Wei Kuo; Jeff H Duyn
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

8.  Polymer thick film technology for improved simultaneous dEEG/MRI recording: Safety and MRI data quality.

Authors:  Catherine Poulsen; Daniel G Wakeman; Seyed Reza Atefi; Phan Luu; Amy Konyn; Giorgio Bonmassar
Journal:  Magn Reson Med       Date:  2016-02-15       Impact factor: 4.668

9.  Electromyogenic Artifacts and Electroencephalographic Inferences Revisited.

Authors:  Brenton W McMenamin; Alexander J Shackman; Lawrence L Greischar; Richard J Davidson
Journal:  Neuroimage       Date:  2010-08-02       Impact factor: 6.556

10.  Validation of ICA-based myogenic artifact correction for scalp and source-localized EEG.

Authors:  Brenton W McMenamin; Alexander J Shackman; Jeffrey S Maxwell; David R W Bachhuber; Adam M Koppenhaver; Lawrence L Greischar; Richard J Davidson
Journal:  Neuroimage       Date:  2009-10-13       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.