Calibration accuracy of hospital-based non-invasive blood pressure measuring devices.

A de Greeff1, I Lorde, A Wilton, P Seed, A J Coleman, A H Shennan.   

Abstract

Accurate blood pressure (BP) measurement is dependent on a trained observer using validated and properly maintained equipment. BP devices should be checked regularly to ensure that their calibration remains within the European Standard specification of +/-3 mm Hg. This study assessed the air leakage rates and calibration accuracy of BP devices in use at a large teaching hospital, using a calibrated electronic pressure gauge as reference. Air leakage rates were recorded over 1 min and static pressures were recorded at 250/200/150/100/50/0 mm Hg for computer download and analysis. A total of 127 devices were assessed (18 mercury, 62 aneroid and 47 automated). In total, 22 different models of devices were available, of which 11 were automated and only 4 had published evidence of a validation using a recognized protocol (British Hypertension Society, Association for the Advancement of Medical Instrumentation or International Protocol). Only 3% (n=4) of devices had an air leakage rate within 4 mm Hg per min and 25% (n=32) of devices failed to meet the European calibration standard of +/-3 mm Hg. Respective failure rates were 6% (1/18) for mercury, 31% (19/62) for aneroid and 26% (12/47) for automated devices. Inaccurate BP measurement of only 3 mm Hg can have detrimental effects in the patient. This study shows a quarter of devices currently in use at a large teaching hospital to have an unacceptable calibration error. Regular maintenance and calibration checks are vital in ensuring that BP is measured as accurately as possible.

Entities:  

Mesh:

Year:  2010        PMID: 19339994     DOI: 10.1038/jhh.2009.29

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  9 in total

1.  Meaningful measurement: developing a measurement system to improve blood pressure control in patients with chronic kidney disease.

Authors:  Jeffrey O Greenberg; Nirav Vakharia; Lara E Szent-Gyorgyi; Sonali P Desai; Alexander Turchin; John Forman; Joseph V Bonventre; Allen Kachalia
Journal:  J Am Med Inform Assoc       Date:  2013-01-23       Impact factor: 4.497

2.  Accuracy of monitors used for blood pressure checks in English retail pharmacies: a cross-sectional observational study.

Authors:  James Hodgkinson; Constantinos Koshiaris; Una Martin; Jonathan Mant; Carl Heneghan; Fd Richard Hobbs; Richard J McManus
Journal:  Br J Gen Pract       Date:  2016-03-29       Impact factor: 5.386

3.  Problems and Solutions in Implementing the World Hypertension League Recommendations for Automated Office Assessment of Blood Pressure.

Authors:  Eugenia V Veiga; Ana C Q G Daniel; Luiz A Bortolloto; Carlos A Machado; Frida L Plavinik; Maria CláudiaIrigoyen; Norm Campbell; John Kenerson; Lyne Cloutier
Journal:  J Clin Hypertens (Greenwich)       Date:  2015-10-12       Impact factor: 3.738

Review 4.  Policy statement of the world hypertension league on noninvasive blood pressure measurement devices and blood pressure measurement in the clinical or community setting.

Authors:  Norm R C Campbell; Adel E Berbari; Lyne Cloutier; Mark Gelfer; John G Kenerson; Tej K Khalsa; Daniel T Lackland; Daniel Lemogoum; Birinder K Mangat; Sailesh Mohan; Martin G Myers; Mark L Niebylski; Eoin O'Brien; George S Stergiou; Eugenia Velludo VeIga; Xin-Hua Zhang
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-05-08       Impact factor: 3.738

5.  Challenges in standardization of blood pressure measurement at the population level.

Authors:  Hanna Tolonen; Päivikki Koponen; Androniki Naska; Satu Männistö; Grazyna Broda; Tarja Palosaari; Kari Kuulasmaa
Journal:  BMC Med Res Methodol       Date:  2015-04-10       Impact factor: 4.615

Review 6.  Diagnosis and management of preeclampsia in community settings in low and middle-income countries.

Authors:  Rehana A Salam; Jai K Das; Anum Ali; Soumyadeep Bhaumik; Zohra S Lassi
Journal:  J Family Med Prim Care       Date:  2015 Oct-Dec

Review 7.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

8.  A survey on personnel awareness of the factors affecting accurate blood pressure measurement in the medical centres of Jahrom County.

Authors:  Safar Zarei; Fatemeh Nasimi; Hassanali Abedi; Najmeh Sadeghi
Journal:  Nurs Open       Date:  2020-04-16

9.  Low cost, non-invasive, and continuous vital signs monitoring device for pregnant women in low resource settings (Lvital device).

Authors:  Kokeb Dese; Gelan Ayana; Gizeaddis Lamesgin Simegn
Journal:  HardwareX       Date:  2022-02-06
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.