Literature DB >> 19319900

3D single-shot VASO using a Maxwell gradient compensated GRASE sequence.

Benedikt A Poser1, David G Norris.   

Abstract

The vascular space occupancy (VASO) method was recently proposed as a functional MRI (fMRI) method that is capable of detecting activation-related changes in blood volume (CBV), without the need for a blood-pool contrast agent. In the present work we introduce a new whole-brain VASO technique that is based on a parallel-accelerated single-shot 3D GRASE (gradient and spin echo) readout. The GRASE VASO sequence employs a flow-compensated correction scheme for concomitant Maxwell gradients which is necessary to avoid smearing artifacts that may occur due to violation of the Carr-Purcell-Meiboom-Gill (CPMG) condition for off-resonance excitation. Experiments with 6 min of visual-motor stimulation were performed on eight subjects. At P < 0.01, average percent signal change and t-score for visual stimulation were -3.11% and -8.42, respectively; activation in left and right motor cortices and supplementary motor area was detected with -2.75% and -6.70, respectively. Sensitivity and signal changes are comparable to those of echo-planar imaging (EPI)-based single-slice VASO, as indicated by additional visual-task experiments (-3.39% and -6.93). The method makes it possible to perform whole-brain cognitive activation studies based on CBV contrast. (c) 2009 Wiley-Liss, Inc.

Mesh:

Year:  2009        PMID: 19319900     DOI: 10.1002/mrm.22000

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

1.  Application of whole-brain CBV-weighted fMRI to a cognitive stimulation paradigm: robust activation detection in a stroop task experiment using 3D GRASE VASO.

Authors:  Benedikt A Poser; David G Norris
Journal:  Hum Brain Mapp       Date:  2010-06-24       Impact factor: 5.038

2.  Multi-parametric neuroimaging reproducibility: a 3-T resource study.

Authors:  Bennett A Landman; Alan J Huang; Aliya Gifford; Deepti S Vikram; Issel Anne L Lim; Jonathan A D Farrell; John A Bogovic; Jun Hua; Min Chen; Samson Jarso; Seth A Smith; Suresh Joel; Susumu Mori; James J Pekar; Peter B Barker; Jerry L Prince; Peter C M van Zijl
Journal:  Neuroimage       Date:  2010-11-20       Impact factor: 6.556

Review 3.  A review of the development of Vascular-Space-Occupancy (VASO) fMRI.

Authors:  Hanzhang Lu; Peter C M van Zijl
Journal:  Neuroimage       Date:  2012-01-08       Impact factor: 6.556

4.  Comparison of BOLD and CBV using 3D EPI and 3D GRASE for cortical layer functional MRI at 7 T.

Authors:  Alexander J S Beckett; Tetiana Dadakova; Jennifer Townsend; Laurentius Huber; Suhyung Park; David A Feinberg
Journal:  Magn Reson Med       Date:  2020-06-18       Impact factor: 4.668

5.  Temporal SNR characteristics in segmented 3D-EPI at 7T.

Authors:  W van der Zwaag; J P Marques; T Kober; G Glover; R Gruetter; G Krueger
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

6.  Measurement of absolute arterial cerebral blood volume in human brain without using a contrast agent.

Authors:  Jun Hua; Qin Qin; James J Pekar; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2011-05-24       Impact factor: 4.044

7.  Techniques for blood volume fMRI with VASO: From low-resolution mapping towards sub-millimeter layer-dependent applications.

Authors:  Laurentius Huber; Dimo Ivanov; Daniel A Handwerker; Sean Marrett; Maria Guidi; Kâmil Uludağ; Peter A Bandettini; Benedikt A Poser
Journal:  Neuroimage       Date:  2016-11-18       Impact factor: 6.556

8.  Inflow-based vascular-space-occupancy (iVASO) MRI.

Authors:  Jun Hua; Qin Qin; Manus J Donahue; Jinyuan Zhou; James J Pekar; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2011-02-24       Impact factor: 4.668

Review 9.  Noise concerns and post-processing procedures in cerebral blood flow (CBF) and cerebral blood volume (CBV) functional magnetic resonance imaging.

Authors:  Manus J Donahue; Meher R Juttukonda; Jennifer M Watchmaker
Journal:  Neuroimage       Date:  2016-09-11       Impact factor: 6.556

Review 10.  Noninvasive functional imaging of cerebral blood volume with vascular-space-occupancy (VASO) MRI.

Authors:  Hanzhang Lu; Jun Hua; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2013-01-28       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.