Literature DB >> 1931352

Influence of colour Doppler echocardiography on the ultrasonic assessment of congenital heart disease: a prospective study.

J P Gnanapragasam1, A B Houston, W B Doig, R Fraser, S Lilley, E Murtagh, G Olafsson.   

Abstract

OBJECTIVE: To evaluate the additional information provided by colour Doppler in the ultrasonic assessment of congenital heart disease. PATIENTS AND METHODS: A prospective study of 215 children (age range 1 day-16 years) presenting with clinical signs of congenital heart disease.
RESULTS: Colour Doppler was essential for the diagnosis of an anomalous left coronary artery and altered the management of a patient initially diagnosed as having cardiomyopathy. Colour Doppler provided extra information, but without major impact on management, in the following: the diagnosis of ventricular septal defects associated with other defects, of multiple ventricular septal defects, of anomalous pulmonary venous drainage, and of mild mitral regurgitation; the demonstration of site of coarctation, of stenotic or hypoplastic pulmonary artery branches, of unobstructed flow through a right atrial membrane, and of left ventricle to right atrium regurgitation; the assessment of the width of the duct and of flow through the patent foramen ovale in transposition and tricuspid atresia; the differentiation of pulmonary atresia from critical pulmonary stenosis and the measurement of maximum velocity of tricuspid regurgitation.
CONCLUSIONS: Ideally all patients should undergo colour Doppler studies before cardiac surgery to ensure a more accurate diagnosis. However, since the additional information provided does not affect the management in most patients, machines without colour Doppler can provide a satisfactory service in paediatric cardiology centres in countries where resources are limited.

Entities:  

Mesh:

Year:  1991        PMID: 1931352      PMCID: PMC1024651          DOI: 10.1136/hrt.66.3.238

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  17 in total

Review 1.  Doppler colour flow mapping: technology in search of an application?

Authors:  M J Monaghan; P Mills
Journal:  Br Heart J       Date:  1989-02

2.  Clinical applications of a new type of real-time two-dimensional Doppler flow imaging system.

Authors:  K Miyatake; M Okamoto; N Kinoshita; S Izumi; M Owa; S Takao; H Sakakibara; Y Nimura
Journal:  Am J Cardiol       Date:  1984-10-01       Impact factor: 2.778

3.  Cross-sectional echocardiographic diagnosis of the sites of total anomalous pulmonary venous drainage.

Authors:  D J Sahn; H D Allen; L W Lange; S J Goldberg
Journal:  Circulation       Date:  1979-12       Impact factor: 29.690

4.  Prospective detection by Doppler color flow imaging of additional defects in infants with a large ventricular septal defect.

Authors:  A J Chin; E T Alboliras; G Barber; J D Murphy; J G Helton; J D Pigott; W I Norwood
Journal:  J Am Coll Cardiol       Date:  1990-06       Impact factor: 24.094

5.  Color Doppler evaluation of valvular regurgitation in normal subjects.

Authors:  K Yoshida; J Yoshikawa; M Shakudo; T Akasaka; Y Jyo; S Takao; K Shiratori; K Koizumi; F Okumachi; H Kato
Journal:  Circulation       Date:  1988-10       Impact factor: 29.690

6.  Localisation of ventricular septal defects by simultaneous display of superimposed colour Doppler and cross sectional echocardiographic images.

Authors:  E Ortiz; P J Robinson; J E Deanfield; R Franklin; F J Macartney; R K Wyse
Journal:  Br Heart J       Date:  1985-07

7.  The role of cross sectional echocardiography and pulsed Doppler ultrasound in the management of neonates in whom congenital heart disease is suspected. A prospective study.

Authors:  M P Leung; C K Mok; K C Lau; R Lo; C Y Yeung
Journal:  Br Heart J       Date:  1986-07

8.  Surgery without catheterization for congenital heart defects: management of 100 patients.

Authors:  J C Huhta; P Glasow; D J Murphy; H P Gutgesell; D A Ott; D G McNamara; E O Smith
Journal:  J Am Coll Cardiol       Date:  1987-04       Impact factor: 24.094

9.  Detection of intracardiac shunt flow in atrial septal defect using a real-time two-dimensional color-coded Doppler flow imaging system and comparison with contrast two-dimensional echocardiography.

Authors:  Y Suzuki; H Kambara; K Kadota; S Tamaki; A Yamazato; R Nohara; G Osakada; C Kawai
Journal:  Am J Cardiol       Date:  1985-08-01       Impact factor: 2.778

10.  Accuracy of two-dimensional echocardiography in the diagnosis of congenital heart disease.

Authors:  H P Gutgesell; J C Huhta; L A Latson; D Huffines; D G McNamara
Journal:  Am J Cardiol       Date:  1985-02-15       Impact factor: 2.778

View more
  1 in total

1.  Does mild pulmonary stenosis progress during childhood? A study of its natural course.

Authors:  Julio Ardura; Carmen Gonzalez; Jesus Andres
Journal:  Clin Cardiol       Date:  2004-09       Impact factor: 2.882

  1 in total