Literature DB >> 3969891

Accuracy of two-dimensional echocardiography in the diagnosis of congenital heart disease.

H P Gutgesell, J C Huhta, L A Latson, D Huffines, D G McNamara.   

Abstract

To assess the accuracy of 2-dimensional (2-D) echocardiography in the evaluation of cardiac anatomy in patients with congenital heart disease, 2-D echocardiograms were performed in 126 infants and children before cardiac catheterization and angiocardiography. The segmental echocardiographic analysis included determination of intracardiac, great artery, systemic venous and pulmonary venous anatomy. The 126 patients had 259 separate cardiovascular abnormalities, of which 226 (87%) were prospectively identified by 2-D echocardiography. There were 8 false-positive diagnoses. The most common lesions and the sensitivity and specificity of echocardiography were: patent ductus arteriosus, 41 patients (83% and 100%, respectively), ventricular septal defect, 35 patients (86% and 100%); atrial septal defect, 26 patients (85% and 99%); pulmonary valve stenosis, 25 patients (77% and 97%), transposition of the great arteries, 16 patients (100% and 100%); and total anomalous pulmonary venous connection, 14 patients (85% and 100%). Less common defects and their rate of detection included coarctation of the aorta, 10 of 12 patients; atrioventricular canal, 10 of 10 patients; tetralogy of Fallot, 10 of 10 patients; aortic valve stenosis 8 of 8 patients; right aortic arch, 8 of 8 patients; interrupted aortic arch, 4 of 4 patients; and unilateral pulmonary vein atresia, 0 of 1 patient. In 33 patients (26%), the errors in echocardiographic analysis were judged to have surgical importance. Most errors were the result of overlooking or misinterpreting data that had been appropriately recorded on videotape. Pulmonary valve stenosis and patent ductus arteriosus are the lesions most likely to be misdiagnosed by ultrasound studies relying on imaging alone.

Entities:  

Mesh:

Year:  1985        PMID: 3969891     DOI: 10.1016/0002-9149(85)90237-1

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  18 in total

1.  An unusual presentation of an atrial septal defect.

Authors:  Min Goo Lee; Jum Suk Ko; Hyun Ju Yoon; Kye Hun Kim; Youngkeun Ahn; Myung Ho Jeong; Jeong Gwan Cho; Jung Chaee Kang; Jong Chun Park
Journal:  J Cardiovasc Ultrasound       Date:  2009-12-31

2.  Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique.

Authors:  I-Chen Tsai; Tain Lee; Min-Chi Chen; Yun-Ching Fu; Sheng-Lin Jan; Chung-Chi Wang; Yen Chang
Journal:  Pediatr Radiol       Date:  2007-06-12

Review 3.  The neonate with congenital heart disease: diagnosis and management.

Authors:  B Chandramouli
Journal:  Indian J Pediatr       Date:  1991 Jul-Aug       Impact factor: 1.967

4.  Usefulness of electrocardiography-gated dual-source computed tomography for evaluating morphological features of the ventricles in children with complex congenital heart defects.

Authors:  Motoo Nakagawa; Masaki Hara; Keita Sakurai; Kazuya Ohashi; Miki Asano; Yuta Shibamoto
Journal:  Jpn J Radiol       Date:  2011-09-17       Impact factor: 2.374

5.  Cardiac Abnormalities in Patients With Hutchinson-Gilford Progeria Syndrome.

Authors:  Ashwin Prakash; Leslie B Gordon; Monica E Kleinman; Ellen B Gurary; Joseph Massaro; Ralph D'Agostino; Mark W Kieran; Marie Gerhard-Herman; Leslie Smoot
Journal:  JAMA Cardiol       Date:  2018-04-01       Impact factor: 14.676

6.  Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility.

Authors:  Tain Lee; I-Chen Tsai; Yun-Ching Fu; Sheng-Lin Jan; Chung-Chi Wang; Yen Chang; Min-Chi Chen
Journal:  Pediatr Radiol       Date:  2006-10-12

7.  The role of cross sectional echocardiography and pulsed Doppler ultrasound in the management of neonates in whom congenital heart disease is suspected. A prospective study.

Authors:  M P Leung; C K Mok; K C Lau; R Lo; C Y Yeung
Journal:  Br Heart J       Date:  1986-07

8.  Influence of colour Doppler echocardiography on the ultrasonic assessment of congenital heart disease: a prospective study.

Authors:  J P Gnanapragasam; A B Houston; W B Doig; R Fraser; S Lilley; E Murtagh; G Olafsson
Journal:  Br Heart J       Date:  1991-09

9.  Diagnostic errors in pediatric echocardiography: development of taxonomy and identification of risk factors.

Authors:  Oscar J Benavidez; Kimberlee Gauvreau; Kathy J Jenkins; Tal Geva
Journal:  Circulation       Date:  2008-06-02       Impact factor: 29.690

10.  Multidetector CT evaluation of total anomalous pulmonary venous connections: comparison with echocardiography.

Authors:  Ki Ho Oh; Ki Seok Choo; Soo Jin Lim; Hyoung Doo Lee; Ji Ae Park; Min Jung Jo; Si Chan Sung; Yun Hee Chang; Dong Wook Jeong; Siho Kim
Journal:  Pediatr Radiol       Date:  2009-06-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.