Literature DB >> 19306757

Influence of rotations on dose distributions in spinal stereotactic body radiotherapy (SBRT).

Orit Gutfeld1, Annette E Kretzler, Rojano Kashani, Daniel Tatro, James M Balter.   

Abstract

PURPOSE: To evaluate the impact of rotational setup errors on dose distribution in spinal stereotactic body radiotherapy (SBRT). METHODS AND MATERIALS: Thirty-nine cone beam computed tomography (CBCT) scans from 16 SBRT treatment courses were analyzed. Alignment (including rotation) to the treatment planning computed tomography was performed, followed by translational alignment that reproduced the actual positioning. The planned fluence was then applied to determine the delivered dose to the targets and organs at risk.
RESULTS: The mean planning target volume (PTV) was 71.01 mL (SD +/- 60.05; range, 22.62-250.65 mL). Prescribed dose (to the 62-82% isodose) was 14-30 Gy in one to six fractions. The average rotational displacements were 0.38 +/- 1.21, 1.12 +/- 1.82, and -0.51 +/- 2.0 degrees with maximal rotations of -4.29, 5.76, and -6.64 degrees along the x (pitch), y (yaw), and z (roll) axes, respectively. PTV coverage changed by an average of -0.07 Gy (SD +/- 0.20 Gy) between the rotated and the original plan, representing 0.92% of prescription dose (SD +/- 2.65%). For the spinal cord, planned with 2-mm expansion to create a planning organ at risk volume (PRV), the difference in minimum dose to the upper 10% of the PRV volume was 0.03 +/- 0.3 Gy (maximum, 0.9 Gy). Other organs at risk saw insignificant changes in dose.
CONCLUSIONS: PRV expansion generally assures safe treatment delivery in the face of typically encountered rotations. Given the variability of delivered dose within this expansion for certain cases, caution should be taken to properly interpret doses to the cord when considering clinical dose limits.

Entities:  

Mesh:

Year:  2009        PMID: 19306757      PMCID: PMC2688767          DOI: 10.1016/j.ijrobp.2008.12.025

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  23 in total

1.  A tilt and roll device for automated correction of rotational setup errors.

Authors:  D C Hornick; D W Litzenberg; K L Lam; J M Balter; J Hetrick; R K Ten Haken
Journal:  Med Phys       Date:  1998-09       Impact factor: 4.071

2.  Radiotherapy for metastatic carcinomas of the kidney or melanomas: an analysis using palliative end points.

Authors:  P U Huguenin; S Kieser; C Glanzmann; R Capaul; U M Lütolf
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-05-01       Impact factor: 7.038

3.  The effect of a single fraction compared to multiple fractions on painful bone metastases: a global analysis of the Dutch Bone Metastasis Study.

Authors:  E Steenland; J W Leer; H van Houwelingen; W J Post; W B van den Hout; J Kievit; H de Haes; H Martijn; B Oei; E Vonk; E van der Steen-Banasik; R G Wiggenraad; J Hoogenhout; C Wárlám-Rodenhuis; G van Tienhoven; R Wanders; J Pomp; M van Reijn; I van Mierlo; E Rutten; J Leer; T van Mierlo
Journal:  Radiother Oncol       Date:  1999-08       Impact factor: 6.280

4.  A phase II trial of palliative radiotherapy for metastatic renal cell carcinoma.

Authors:  Justin Lee; David Hodgson; Edward Chow; Andrea Bezjak; Pamela Catton; Debbie Tsuji; Mary O'Brien; Cyril Danjoux; Charles Hayter; Padraig Warde; Mary K Gospodarowicz
Journal:  Cancer       Date:  2005-11-01       Impact factor: 6.860

5.  Randomized trial of short- versus long-course radiotherapy for palliation of painful bone metastases.

Authors:  William F Hartsell; Charles B Scott; Deborah Watkins Bruner; Charles W Scarantino; Robert A Ivker; Mack Roach; John H Suh; William F Demas; Benjamin Movsas; Ivy A Petersen; Andre A Konski; Charles S Cleeland; Nora A Janjan; Michelle DeSilvio
Journal:  J Natl Cancer Inst       Date:  2005-06-01       Impact factor: 13.506

6.  Calculation of rotational setup error using the real-time tracking radiation therapy (RTRT) system and its application to the treatment of spinal schwannoma.

Authors:  Rikiya Onimaru; Hiroki Shirato; Hidefumi Aoyama; Kei Kitakura; Toshitaka Seki; Kazutoshi Hida; Katsuhisa Fujita; Kenji Kagei; Takeshi Nishioka; Tatsuya Kunieda; Yoshinobu Iwasaki; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-11-01       Impact factor: 7.038

7.  Patterns of failure after single-dose radiosurgery for spinal metastasis.

Authors:  Samuel Ryu; Jack Rock; Mark Rosenblum; Jae Ho Kim
Journal:  J Neurosurg       Date:  2004-11       Impact factor: 5.115

8.  Stereotactic radiosurgery for spinal metastases from renal cell carcinoma.

Authors:  Peter C Gerszten; Steven A Burton; Cihat Ozhasoglu; William J Vogel; William C Welch; Joseph Baar; David M Friedland
Journal:  J Neurosurg Spine       Date:  2005-10

9.  Adequate margins for random setup uncertainties in head-and-neck IMRT.

Authors:  Eleftheria Astreinidou; Arjan Bel; Cornelis P J Raaijmakers; Chris H J Terhaard; Jan J W Lagendijk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-03-01       Impact factor: 7.038

10.  Randomized trial of 8 Gy in 1 versus 20 Gy in 5 fractions of radiotherapy for neuropathic pain due to bone metastases (Trans-Tasman Radiation Oncology Group, TROG 96.05).

Authors:  Daniel E Roos; Sandra L Turner; Peter C O'Brien; Jennifer G Smith; Nigel A Spry; Bryan H Burmeister; Peter J Hoskin; David L Ball
Journal:  Radiother Oncol       Date:  2004-10-28       Impact factor: 6.280

View more
  4 in total

1.  Dosimetric impact of angular deviations in positioning for spinal radiosurgery.

Authors:  Jinkoo Kim; Jian-Yue Jin; Ning Wen; Samir H Patel; Benjamin Movsas; Jack Rock; Indrin J Chetty; Samuel Ryu
Journal:  J Radiosurg SBRT       Date:  2012

2.  Dosimetric consequences of rotational setup errors with direct simulation in a treatment planning system for fractionated stereotactic radiotherapy.

Authors:  Jean L Peng; Chihray Liu; Yu Chen; Robert J Amdur; Kenneth Vanek; Jonathan G Li
Journal:  J Appl Clin Med Phys       Date:  2011-04-04       Impact factor: 2.102

3.  Dosimetric study for spine stereotactic body radiation therapy: magnetic resonance guided linear accelerator versus volumetric modulated arc therapy.

Authors:  Poonam Yadav; Hima B Musunuru; Jacob S Witt; Michael Bassetti; John Bayouth; Andrew M Baschnagel
Journal:  Radiol Oncol       Date:  2019-09-24       Impact factor: 2.991

4.  Is Halcyon feasible for single thoracic or lumbar vertebral segment SBRT?

Authors:  Fang Li; Jeonghoon Park; Ron Lalonde; Si Young Jang; Maria Stefania diMayorca; John C Flickinger; Andrew Keller; Mohammed Saiful Huq
Journal:  J Appl Clin Med Phys       Date:  2021-11-29       Impact factor: 2.102

  4 in total