Literature DB >> 29296326

Dosimetric impact of angular deviations in positioning for spinal radiosurgery.

Jinkoo Kim1, Jian-Yue Jin1, Ning Wen1, Samir H Patel2, Benjamin Movsas1, Jack Rock1, Indrin J Chetty1, Samuel Ryu1.   

Abstract

PURPOSE: During image-guided radiosurgery, it is common to account only for translational shifts while leaving rotational deviations uncorrected. The aim of this study is to investigate the rotational setup deviations and estimate the dosimetric impact in spinal radiosurgery.
MATERIALS AND METHODS: Stereoscopic image registrations of 711 spine radiosurgery procedures (546 patients) were retrospectively reviewed and classified to cervical (C), thoracic (T), and lumbar (L) spines. The probability of rotational deviations were estimated in three orthogonal axis. In order to investigate the dosimetric impact, the original simulation CT images were rotated in the range of ±5 deg in each axis. Then, the dosimetric changes were recorded; including the coverage (V90) and minimum dose (Dmin) to the target, and the dose of 10% volume (D10) and maximum dose (Dmax) to the spinal cord.
RESULTS: Target rotations of >5 deg and >3 deg occurred respectively in 1% and 8% of cases. The mean rotations were small (|μ|<0.6 deg) with no axis and site dependent trends. The standard deviations (σ) of different sites and axes ranged from 1.4 to 2.0 deg (mean σ=1.7 deg). The overall dosimetric changes of the target coverage(V90) and cord D10 were small. Five degree rotation resulted in a target V90 decrease of 1±1%, 2±2% and 3±1%, respectively in the lateral, vertical, and longitudinal axes. The corresponding cord D10 increased by 3±6%, 2±2%, and 6±5%. The changes in cord Dmax ranged from 92% to 138% of the original reference spinal cord. Corresponding changes in target Dmin were 59~106%.
CONCLUSION: Large target rotations occurred in a small percentage of patients. The overall dosimetric impact on target coverage and cord D10 was small. However larger effects were observed on the target Dmin and cord Dmax. Special care must be taken for targets of elongated shapes involving multiple vertebrae.

Entities:  

Keywords:  Spinal radiosurgery; angular deviation; dosimetric impact; image-guided radiation therapy; spinal cord dose

Year:  2012        PMID: 29296326      PMCID: PMC5658860     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  20 in total

1.  A study of the accuracy of cyberknife spinal radiosurgery using skeletal structure tracking.

Authors:  Anthony K Ho; Dongshan Fu; Cristian Cotrutz; Steven L Hancock; Steven D Chang; Iris C Gibbs; Calvin R Maurer; John R Adler
Journal:  Neurosurgery       Date:  2007-02       Impact factor: 4.654

2.  Radiosurgery for spinal metastases: clinical experience in 500 cases from a single institution.

Authors:  Peter C Gerszten; Steven A Burton; Cihat Ozhasoglu; William C Welch
Journal:  Spine (Phila Pa 1976)       Date:  2007-01-15       Impact factor: 3.468

3.  Use of the BrainLAB ExacTrac X-Ray 6D system in image-guided radiotherapy.

Authors:  Jian-Yue Jin; Fang-Fang Yin; Stephen E Tenn; Paul M Medin; Timothy D Solberg
Journal:  Med Dosim       Date:  2008-04-01       Impact factor: 1.482

Review 4.  kV cone-beam CT-based IGRT: a clinical review.

Authors:  Judit Boda-Heggemann; Frank Lohr; Frederik Wenz; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

Review 5.  The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide.

Authors:  Stine Korreman; Coen Rasch; Helen McNair; Dirk Verellen; Uwe Oelfke; Philippe Maingon; Ben Mijnheer; Vincent Khoo
Journal:  Radiother Oncol       Date:  2010-02-12       Impact factor: 6.280

6.  CyberKnife radiosurgery for benign intradural extramedullary spinal tumors.

Authors:  Robert L Dodd; Mi-Ryeong Ryu; Pimkhuan Kamnerdsupaphon; Iris C Gibbs; Steven D Chang; John R Adler
Journal:  Neurosurgery       Date:  2006-04       Impact factor: 4.654

7.  Partial volume tolerance of the spinal cord and complications of single-dose radiosurgery.

Authors:  Samuel Ryu; Jian-Yue Jin; Ryan Jin; Jack Rock; Munther Ajlouni; Benjamin Movsas; Mark Rosenblum; Jae Ho Kim
Journal:  Cancer       Date:  2007-02-01       Impact factor: 6.860

8.  Spinal cord tolerance for stereotactic body radiotherapy.

Authors:  Arjun Sahgal; Lijun Ma; Iris Gibbs; Peter C Gerszten; Sam Ryu; Scott Soltys; Vivian Weinberg; Shun Wong; Eric Chang; Jack Fowler; David A Larson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-09-16       Impact factor: 7.038

9.  Evaluation of residual patient position variation for spinal radiosurgery using the Novalis image guided system.

Authors:  Jian-Yue Jin; Samuel Ryu; Jack Rock; Kathleen Faber; Qing Chen; Munther Ajlouni; Benjamin Movsas
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

10.  Precision required for dose-escalated treatment of spinal metastases and implications for image-guided radiation therapy (IGRT).

Authors:  Matthias Guckenberger; Juergen Meyer; Juergen Wilbert; Kurt Baier; Klaus Bratengeier; Dirk Vordermark; Michael Flentje
Journal:  Radiother Oncol       Date:  2007-06-11       Impact factor: 6.280