Literature DB >> 9775381

A tilt and roll device for automated correction of rotational setup errors.

D C Hornick1, D W Litzenberg, K L Lam, J M Balter, J Hetrick, R K Ten Haken.   

Abstract

A tilt and roll device has been developed to add two additional degrees of freedom to an existing treatment table. This device allows computer-controlled rotational motion about the inferior-superior and left-right patient axes. The tilt and roll device comprises three supports between the tabletop and base. An automotive type universal joint welded to the end of a steel pipe supports the center of the table. Two computer-controlled linear electric actuators utilizing high accuracy stepping motors support the foot of table and control the tilt and roll of the tabletop. The current system meets or exceeds all pre-design specifications for precision, weight capacity, rigidity, and range of motion.

Entities:  

Mesh:

Year:  1998        PMID: 9775381     DOI: 10.1118/1.598355

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Novel correction methods as alternatives for the six-dimensional correction in CyberKnife treatment.

Authors:  Osamu Suzuki; Hiroya Shiomi; Satoaki Nakamura; Fumitoshi Nakayama; Yasuo Yoshioka; Takehiro Inoue
Journal:  Radiat Med       Date:  2007-01-25

2.  Spine Stereotactic Body Radiotherapy to Three or More Contiguous Vertebral Levels.

Authors:  Khaled Dibs; Dukagjin M Blakaj; Rahul N Prasad; Alexander Olausson; Eric C Bourekas; Daniel Boulter; Ahmet S Ayan; Eric Cochran; William S Marras; Prasath Mageswaran; Evan Thomas; Hyeri Lee; John Grecula; Raju R Raval; Ehud Mendel; Thomas Scharschmidt; Russell Lonser; Arnab Chakravarti; James B Elder; Joshua D Palmer
Journal:  Front Oncol       Date:  2022-06-08       Impact factor: 5.738

3.  Influence of rotations on dose distributions in spinal stereotactic body radiotherapy (SBRT).

Authors:  Orit Gutfeld; Annette E Kretzler; Rojano Kashani; Daniel Tatro; James M Balter
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-04-01       Impact factor: 7.038

4.  Theoretical foundation for real-time prostate localization using an inductively coupled transmitter and a superconducting quantum interference device (SQUID) magnetometer system.

Authors:  John E McGary
Journal:  J Appl Clin Med Phys       Date:  2004-10-01       Impact factor: 2.102

5.  A comparison of computer-controlled versus manual on-line patient setup adjustment.

Authors:  Kristy K Brock; Daniel L McShan; James M Balter
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

6.  Accuracy of automatic couch corrections with on-line volumetric imaging.

Authors:  Winnie Li; Douglas J Moseley; Tony Manfredi; David A Jaffray
Journal:  J Appl Clin Med Phys       Date:  2009-10-07       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.