Literature DB >> 19306404

Accelerated phase-contrast MR imaging: comparison of k-t BLAST with SENSE and Doppler ultrasound for velocity and flow measurements in the aorta.

Andreas Stadlbauer1, Wilma van der Riet, Sebastian Globits, Gerard Crelier, Erich Salomonowitz.   

Abstract

PURPOSE: To evaluate differences in velocity and flow measurements in the aorta between accelerated phase-contrast (PC) magnetic resonance imaging (MRI) using SENSE and k-t BLAST and in peak velocity to Doppler ultrasound.
MATERIALS AND METHODS: Two-dimensional PC-MRI perpendicular to the ascending and descending aorta was performed in 11 volunteers using SENSE (R = 2) and k-t BLAST (2-, 4-, 6-, and 8-fold). Peak velocity, mean velocity, and stroke volume of the accelerated PC-MRI experiments were correlated. Peak velocities were compared to Doppler ultrasound.
RESULTS: All acceleration techniques showed significant correlations for peak velocity with Doppler ultrasound. However, k-t BLAST 6 and 8 showed a significant underestimation. Strong correlations between SENSE and k-t BLAST were found for all three parameters. Significant differences in peak velocity were found between SENSE and all k-t BLAST experiments, but not for 2-fold k-t BLAST in the ascending aorta, and 2- and 4-fold k-t BLAST in the descending aorta. For mean velocity no significant differences were found. Stroke volume showed significant differences for all k-t BLAST experiments in the ascending and for 6- and 8-fold k-t BLAST in the descending aorta.
CONCLUSION: Peak velocity of accelerated PC-MRI correlated with CW Doppler measurements, but high k-t BLAST acceleration factors lead to a significant underestimation. SENSE with R = 2 and 2-fold k-t BLAST are most highly correlated in phase-contrast flow measurements.

Entities:  

Mesh:

Year:  2009        PMID: 19306404     DOI: 10.1002/jmri.21706

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  14 in total

1.  Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study.

Authors:  Bjoern P Schoennagel; Chressen C Remus; Jin Yamamura; Fabian Kording; Manuela Tavares de Sousa; Manuela Tavares de Sousa; Kurt Hecher; Roland Fischer; Friedrich Ueberle; Matthias Boehme; Gerhard Adam; Hendrik Kooijman; Ulrike Wedegaertner
Journal:  MAGMA       Date:  2013-08-10       Impact factor: 2.310

2.  Fetal dynamic phase-contrast MR angiography using ultrasound gating and comparison with Doppler ultrasound measurements.

Authors:  B P Schoennagel; J Yamamura; F Kording; R Fischer; P Bannas; G Adam; H Kooijman; C Ruprecht; K Fehrs; M Tavares de Sousa
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

3.  k-t BLAST and SENSE accelerated time-resolved three-dimensional phase contrast MRI in an intracranial aneurysm.

Authors:  Pim van Ooij; Annetje Guédon; Henk A Marquering; Joppe J Schneiders; Charles B Majoie; Ed van Bavel; Aart J Nederveen
Journal:  MAGMA       Date:  2012-09-07       Impact factor: 2.310

4.  K-t GRAPPA-accelerated 4D flow MRI of liver hemodynamics: influence of different acceleration factors on qualitative and quantitative assessment of blood flow.

Authors:  Zoran Stankovic; Jury Fink; Jeremy D Collins; Edouard Semaan; Maximilian F Russe; James C Carr; Michael Markl; Mathias Langer; Bernd Jung
Journal:  MAGMA       Date:  2014-08-07       Impact factor: 2.310

5.  Comparison of blood velocity measurements between ultrasound Doppler and accelerated phase-contrast MR angiography in small arteries with disturbed flow.

Authors:  Jingfeng Jiang; Charles Strother; Kevin Johnson; Sara Baker; Dan Consigny; Oliver Wieben; James Zagzebski
Journal:  Phys Med Biol       Date:  2011-02-23       Impact factor: 3.609

6.  k-t GRAPPA accelerated four-dimensional flow MRI in the aorta: effect on scan time, image quality, and quantification of flow and wall shear stress.

Authors:  Susanne Schnell; Michael Markl; Pegah Entezari; Riti J Mahadewia; Edouard Semaan; Zoran Stankovic; Jeremy Collins; James Carr; Bernd Jung
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

7.  Velocity measurements in the middle cerebral arteries of healthy volunteers using 3D radial phase-contrast HYPRFlow: comparison with transcranial Doppler sonography and 2D phase-contrast MR imaging.

Authors:  W Chang; B Landgraf; K M Johnson; S Kecskemeti; Y Wu; J Velikina; H Rowley; O Wieben; C Mistretta; P Turski
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-14       Impact factor: 3.825

8.  Highly accelerated cardiac cine phase-contrast MRI using an undersampled radial acquisition and temporally constrained reconstruction.

Authors:  Jordan P Hulet; Andreas Greiser; Jason K Mendes; Chris McGann; Gerald Treiman; Dennis L Parker
Journal:  J Magn Reson Imaging       Date:  2013-04-30       Impact factor: 4.813

9.  Acceleration of tissue phase mapping with sensitivity encoding at 3T.

Authors:  Anja Lutz; Axel Bornstedt; Robert Manzke; Patrick Etyngier; G Ulrich Nienhaus; Wolfgang Rottbauer; Volker Rasche
Journal:  J Cardiovasc Magn Reson       Date:  2011-10-12       Impact factor: 5.364

10.  Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T.

Authors:  Marcus Carlsson; Johannes Töger; Mikael Kanski; Karin Markenroth Bloch; Freddy Ståhlberg; Einar Heiberg; Håkan Arheden
Journal:  J Cardiovasc Magn Reson       Date:  2011-10-04       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.