Protrusio of a ceramic femoral head through the acetabular metallic shell, extensive metallosis and 'bubble sign'.

Konstantinos Malizos1, Nikolaos T Roidis, Lazaros Poultsides, George Basdekis, Theofanis Moraitis, Theodoros Xenakis.   

Abstract

A 24-year-old patient with a history of juvenile rheumatoid arthritis underwent a primary cementless left total hip arthroplasty (THA). The original THA consisted of an Optifix 54 cup with a 3-mm thick polyethylene liner, an Optifix size 4 stem (Smith & Nephew Richards, Memphis, Tennessee) and a Biolox aluminum 32-mm femoral head. Fourteen years later, radiographs demonstrated extensive wear of the polyethylene liner resulting in direct articulation and abrasion wear of the ceramic femoral head on the cup and a bubble sign. This article presents a case of a catastrophic failure of a ceramic/polyethylene bearing with destruction of the polyethylene liner and the metallic shell and protrusio of the nonfractured ceramic head through the metallic shell. To our knowledge this is the first description of extensive metallosis and subsequent radiograph bubble sign not presenting as a result of wear of a metal-on-metal articulation. At the time of revision surgery-Hydrocel TNT Monoblock 58 cup (Zimmer, Warsaw, Indiana), Wagner 265/14 stem (Zimmer), and a Co/Cr 28-mm head-copious metallic debris was seen both macroscopically and histologically, with the ceramic head protruding behind the metallic shell. Multiple factors may have been responsible for this failure including a thin polyethylene shell, a suboptimal locking mechanism, gamma in air sterilization for polyethylene, multiple screw-holes that reduce the contact surface between shell and polyethylene, the rough surface on the inside of the shell and non-articular wear at the metal polyethylene interface within the acetabular component and the high demands of this active young patient.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19301791

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  5 in total

1.  Severe metallosis following oxidised zirconium wear in total hip arthroplasty.

Authors:  Erato Gkouliopoulou; Filon Agathangelidis; Themistoklis Vampertzis; Thomas Ntovas
Journal:  BMJ Case Rep       Date:  2016-10-31

2.  Catastrophic failure of ceramic-on-ceramic total hip arthroplasty presenting as squeaking hip.

Authors:  David Malem; Mathias Thomas Nagy; Sabyasachi Ghosh; Bhavik Shah
Journal:  BMJ Case Rep       Date:  2013-02-20

3.  Metallosis: CT findings in a total hip arthroplasty.

Authors:  Jared R Kirkham; Jonelle M Petscavage; Michael L Richardson
Journal:  Radiol Case Rep       Date:  2015-11-06

4.  Prosthetic femoral head erosion through an acetabular component treated with revision and implant preservation.

Authors:  Mark Daniel Kohn; Navin Fernando
Journal:  Arthroplast Today       Date:  2020-01-14

5.  Do Not Postpone Revision of Worn Conventional Liners in Ceramic-on-Polyethylene Total Hip Arthroplasty: A New Dramatic Failure.

Authors:  Thorsten Gehrke; Mustafa Citak; Hussein Abdelaziz
Journal:  Arthroplast Today       Date:  2021-07-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.