Metallosis: CT findings in a total hip arthroplasty.

Jared R Kirkham, Jonelle M Petscavage, Michael L Richardson.   

Abstract

We report a case of a 50-year-old man with extensive metallosis 20 years after right total hip arthroplasty. CT demonstrated osteolysis and radiodense debris surrounding the right hip joint. Although the radiographic appearance of metallosis has been well documented in the literature, the CT appearance of metallosis after total hip arthroplasty has been only sparsely described.

Entities:  

Keywords:  CT, computed tomography; THA, total hip arthroplasty

Year:  2015        PMID: 27307862      PMCID: PMC4898222          DOI: 10.2484/rcr.v5i2.410

Source DB:  PubMed          Journal:  Radiol Case Rep        ISSN: 1930-0433


Case report

A 50-year-old man with sickle cell disease and a 20-year history of bilateral total hip arthroplasties for avascular necrosis presented with progressive worsening of right hip pain and stiffness. When initially evaluated in the orthopedic clinic, he walked with a trendelenburg gait on the right and limited range of motion in his right hip compared to the left. At that time, radiographs of the pelvis demonstrated complete wear of the polyethylene acetabular liner of the right hip arthroplasty, with extensive osteolysis. There were also fractures of the greater trochanter, lesser trochanter, and right superior and inferior pubic rami (Fig. 1). Noncontrast CT of the pelvis further demonstrated the extent of the osteolysis and fractures. CT also showed non-x-ray-apparent fluid-attenuation collections with high-density-material rims along the synovial margins of the right hip joint (Figure 2, Figure 3).
Figure 1

50-year-old man with extensive metallosis. Judet view of the pelvis shows bilateral total hip arthroplasties. There is osteolysis of the right greater and lesser trochanters and acetabulum. Also seen are fractures of the right superior and inferior pubic rami.

Figure 2

50-year-old man with extensive metallosis. Axial CT of the pelvis in bone windows shows osteolysis of the right acetabulum with foci of small metallic debris. The medial acetabular wall is completely destroyed.

Figure 3

50-year-old man with extensive metallosis. Noncontrast CT of the right hip joint, at the level of the inferior pubic ramus, shows several round, fluid-density collections with high-density peripheral rims, which are located both anterolaterally and posteromedially along the capsule of the right hip joint. Artifact from right hip prostheses is also present.

Due to the failure of his right hip arthroplasty, the patient subsequently underwent surgical revision. Operative notes document full wear-through of the polyethylene acetabular liner with abnormal metal-on-metal articulation and significant metallic and granulomatous debris staining the surrounding tissues. However, the metal acetabular cup and femoral components were well fixed. Therefore, the revision consisted of an exchange of the acetabular polyethylene liner and femoral head, with debridement of the surrounding metallic stained tissue. The patient functionally did well for six months. However, he returned with progressively worsening deep lateral right thigh pain, to the point of needing crutches for ambulation. Laboratory evaluation confirmed no evidence of infection. Radiographs and noncontrast CT of the pelvis revealed a new fracture of the right acetabulum with significant superior subluxation of the hip and extensive surrounding osteolysis (Fig. 4). Numerous round, soft-tissue masses with high-density walls were again seen outlining the right hip joint.
Figure 4

50-year-old man with extensive metallosis. Radiogaph of the right hip shows further osteolysis of the greater and lesser trochanters and right acetabulum. A new fracture of the superior acetabular wall is present with superior migration of the femur. Small metallic particles are now seen on radiographs surrounding the hip prosthesis.

Due to the presence of multiple soft-tissue ulcers, surgery was not performed. Repeat CT six months later showed further progression of prosthesis failure, with worsening osteolysis of both the anterior and posterior columns of the right acetabulum. There was also further accumulation of radiodense debris, and increased size and number of metallic-rimmed fluid collections. Findings were consistent with advanced metallosis (Figure 5, Figure 6, Figure 7A, Figure 7B, Figure 7C).
Figure 5

50-year-old man with extensive metallosis. Coronal reformatted CT of the pelvis without contrast in bone algorithm shows complete osteolysis of the right acetabulum with the space replaced by soft-tissue density and multiple foci of metallic debris, suggestive of advanced metallosis. The right femur is superiorly subluxated.

Figure 6

50-year-old man with extensive metallosis. Axial image from noncontrast CT of the pelvis shows more round, fluid-density lesions with metallic-density peripheral rims. The lesions are anteromedial and posterolateral to the prosthesis, along the hip joint capsule.

Figure 7A

Volume-rendered 3D reformation of CT of prostheses. Medial surface of left acetabular component.

Figure 7B

Volume-rendered 3D reformation of CT of prostheses. Medial surface of the displaced right acetabular component. The abnormal articulation between this component and the ilium has worn a circular hole (arrows) in the component.

Figure 7C

Volume-rendered 3D reformation of CT of prostheses. QuickTime 3D movie (893 kB) of both prostheses.

Discussion

Metallosis is a rare condition defined by infiltration of periprosthetic soft tissues and bone by metallic debris resulting from wear of joint arthroplasties (1). The accumulation of metallic debris can further accelerate wear and loosening of the hardware components by instigating a local inflammatory response with synovitis and cytokine-mediated osteolysis (2, 3, 4). In the setting of total hip arthroplasty (THA), metallosis can occur by a variety of mechanisms. For metal-on-metal THAs, the metal femoral head may wear against the weight-bearing surface of the metal acetabular component (5, 6). Alternatively, if the implant is improperly positioned, the femoral neck may impinge on the acetabular cup (7). As in this case, metallosis may also occur in THAs that have been constructed with polyethylene liners. The polyethylene liner may fracture or wear down from overuse, resulting in abnormal metal-on-metal contact and the dispersion of metal particles within the joint (8, 9, 10, 11). In a review of 418 THAs, the overall incidence of metallosis as the cause of THA failures was approximately 5.3% (12). There are several characteristic radiographic features of metallosis in THA. On plain films, eccentric alignment of the femoral head in the acetabular cup may suggest wear, fracture, or breakdown of the polyethylene liner. Another finding is the bubble sign, seen as bubble-like hyperdensities representing deposited metallic debris outlining the joint space (13). The cloud sign is described as amorphous cloudy radiodensities in the periprosthetic tissues (14). In advanced cases such as this one, metallosis may be seen as gross metallic particulate matter in the periprosthetic tissues, which may lead to extensive osteolysis in the surrounding bone. Unfortunately, these radiographic signs may be absent in over half of cases (12). Therefore, CT may aid in diagnosis. Cases demonstrating the imaging findings of metallosis on CT are sparsely documented in the literature. Findings include high-density material outlining the joint capsule or bursa (1, 15). Our case report further documents the imaging appearance of metallosis on CT, with the unique findings of metallic debris in addition to high-density material outlining the hip joint capsule. This case of metallosis is particularly unusual in that it occurs in the context of sickle cell disease, which is associated with a high incidence of polyethylene wear and osteolysis requiring re-operation (16, 17). Due to the severe consequences of metallosis, including chronic inflammation, osteolysis, and prosthetic loosening, as well as the inconsistent appearance of metallosis on plain film, we recommend CT in conjunction with plain films when evaluating the integrity of total hip arthroplasties. This will allow timely detection of metallosis, prompt revision arthroplasty, and minimization of osteolysis.
  17 in total

1.  Wear-through of a modular polyethylene liner: four case reports.

Authors:  C A Engh; R H Hopper; C A Engh; J P McAuley
Journal:  Clin Orthop Relat Res       Date:  2001-02       Impact factor: 4.176

2.  The bubble sign: a new radiographic sign in total hip arthroplasty.

Authors:  Edwin P Su; Peter W Callander; Eduardo A Salvati
Journal:  J Arthroplasty       Date:  2003-01       Impact factor: 4.757

3.  Metallosis after contemporary metal-on-metal total hip arthroplasty. Five to nine-year follow-up.

Authors:  P Korovessis; G Petsinis; M Repanti; T Repantis
Journal:  J Bone Joint Surg Am       Date:  2006-06       Impact factor: 5.284

4.  Severe metallosis after unicompartmental knee arthroplasty.

Authors:  Vicente Sanchis-Alfonso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-07       Impact factor: 4.342

5.  The imaging appearances of metallosis.

Authors:  E J Heffernan; F O Alkubaidan; T O Nielsen; P L Munk
Journal:  Skeletal Radiol       Date:  2007-09-18       Impact factor: 2.199

Review 6.  Metallosis after metal-on-polyethylene total hip arthroplasty.

Authors:  Cara A Cipriano; Paul S Issack; Burak Beksac; Alejandro Gonzalez Della Valle; Thomas P Sculco; Eduardo A Salvati
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2008-02

7.  The natural history of metallosis from catastrophic failure of a polyethylene liner in a total hip.

Authors:  Riaz J K Khan; James Wimhurst; Sara Foroughi; Andoni Toms
Journal:  J Arthroplasty       Date:  2008-10-09       Impact factor: 4.757

8.  Revision total hip arthroplasty in hip joints with metallosis: a single-center experience with 31 cases.

Authors:  Jun-Dong Chang; Sang-Soo Lee; Mina Hur; Eun-Min Seo; Yung-Khee Chung; Chang-Ju Lee
Journal:  J Arthroplasty       Date:  2005-08       Impact factor: 4.757

9.  Extensive metallosis and necrosis in failed prostheses with cemented titanium-alloy stems and ceramic heads.

Authors:  L Miloŝev; V Antoliĉ; A Minoviĉ; A Cör; S Herman; V Pavlovcic; P Campbell
Journal:  J Bone Joint Surg Br       Date:  2000-04

10.  Massive wear of an incompatible metal-on-metal articulation in total hip arthroplasty.

Authors:  Johannes B Keel; Markus S Kuster
Journal:  J Arthroplasty       Date:  2004-08       Impact factor: 4.757

View more
  2 in total

1.  Metallosis in shoulder arthroplasty: an integrative review of literature.

Authors:  Paritosh Gogna; Paolo Paladini; Giovanni Merolla; Carlo Alberto Augusti; De Falco Maddalena; Giuseppe Porcellini
Journal:  Musculoskelet Surg       Date:  2016-11-30

Review 2.  The contribution of the histopathological examination to the diagnosis of adverse local tissue reactions in arthroplasty.

Authors:  Giorgio Perino; Ivan De Martino; Lingxin Zhang; Zhidao Xia; Jiri Gallo; Shonali Natu; David Langton; Monika Huber; Anastasia Rakow; Janosch Schoon; Enrique Gomez-Barrena; Veit Krenn
Journal:  EFORT Open Rev       Date:  2021-06-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.