Development of a multi-layer ionization chamber for heavy-ion radiotherapy.

Kaori Yajima1, Tatsuaki Kanai, Yohsuke Kusano, Takuya Shimojyu.   

Abstract

A multi-layer ionization chamber (MLIC) which consists of a stack of parallel plate-type ionization chambers in which the parallel configuration is in the depth direction was developed at the National Institute of Radiological Science (NIRS) and has been used as a field dosimeter for MU calibration since 2002. Although the MLIC can measure depth dose distributions at one time, a correction is needed to obtain an accurate dose at the center of the spread-out Bragg peak (SOBP) in a water phantom. We attributed the observed difference between the correct dose at the center of the SOBP and the measured dose to the lack of water equivalence of the MLIC. In order to overcome this problem, a new MLIC was developed. It consists of polymethyl-methacrylate (PMMA) plates and graphite electrodes instead of flame retardant type 4 (FR4) and copper electrodes. The calibration coefficients of the MLICs were obtained by 160 MeV proton beam irradiation. For carbon-ion beams, the PMMA type MLIC has the capability to measure depth dose distributions in the water phantom with less than 2% error, including the fragment tail region.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19293471     DOI: 10.1088/0031-9155/54/7/N04

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Characterization of a MLIC Detector for QA in Scanned Proton and Carbon Ion Beams.

Authors:  Alessandro Vai; Alfredo Mirandola; Giuseppe Magro; Davide Maestri; Edoardo Mastella; Andrea Mairani; Silvia Molinelli; Stefania Russo; Michele Togno; Sara La Civita; Mario Ciocca
Journal:  Int J Part Ther       Date:  2019-11-26

2.  Margin estimation and disturbances of irradiation field in layer-stacking carbon-ion beams for respiratory moving targets.

Authors:  Shinya Tajiri; Mutsumi Tashiro; Tomohiro Mizukami; Chihiro Tsukishima; Masami Torikoshi; Tatsuaki Kanai
Journal:  J Radiat Res       Date:  2017-11-01       Impact factor: 2.724

3.  Evaluation of detectors for acquisition of pristine depth-dose curves in pencil beam scanning.

Authors:  Christian Bäumer; Benjamin Koska; Jamil Lambert; Beate Timmermann; Thierry Mertens; Patrick Takoukam Talla
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.