Literature DB >> 19287079

A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol.

Greg Carnes1, Stewart Gaede, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee.   

Abstract

Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy chaining' all couch positions using the selected images until an entire 3D volume was produced. The algorithm produced 16 phase volumes to complete a 4D-CT dataset. Additional 4D-CT datasets were also produced using external marker amplitude and phase angle sorting methods. The image quality of the volumes produced by the different methods was quantified by calculating the mean difference of the sorted overlapping slices from adjacent couch positions. The NCC sorted images showed a significant decrease in the mean difference (p < 0.01) for the five patients.

Entities:  

Mesh:

Year:  2009        PMID: 19287079     DOI: 10.1088/0031-9155/54/7/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model.

Authors:  Agung Hertanto; Qinghui Zhang; Yu-Chi Hu; Oleksandr Dzyubak; Andreas Rimner; Gig S Mageras
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

2.  Reconstruction of four-dimensional computed tomography lung images by applying spatial and temporal anatomical constraints using a Bayesian model.

Authors:  Tiancheng He; Zhong Xue; Bin S Teh; Stephen T Wong
Journal:  J Med Imaging (Bellingham)       Date:  2015-05-13

3.  Dynamic dual-energy chest radiography: a potential tool for lung tissue motion monitoring and kinetic study.

Authors:  Tong Xu; Justin L Ducote; Jerry T Wong; Sabee Molloi
Journal:  Phys Med Biol       Date:  2011-02-01       Impact factor: 3.609

4.  Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

Authors:  Min Li; Sarah Joy Castillo; Richard Castillo; Edward Castillo; Thomas Guerrero; Liang Xiao; Xiaolin Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-14       Impact factor: 2.924

5.  Characterization and identification of spatial artifacts during 4D-CT imaging.

Authors:  Dongfeng Han; John Bayouth; Sudershan Bhatia; Milan Sonka; Xiaodong Wu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

Review 6.  Advances in 4D radiation therapy for managing respiration: part I - 4D imaging.

Authors:  Geoffrey D Hugo; Mihaela Rosu
Journal:  Z Med Phys       Date:  2012-07-10       Impact factor: 4.820

7.  New Data-Driven Gated PET/CT Free of Misregistration Artifacts.

Authors:  Tinsu Pan; Yang Lu; M Allan Thomas; Zhongxing Liao; Dershan Luo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2020-11-10       Impact factor: 7.038

8.  Data-driven gated CT: An automated respiratory gating method to enable data-driven gated PET/CT.

Authors:  Tinsu Pan; M Allan Thomas; Dershan Luo
Journal:  Med Phys       Date:  2022-04-22       Impact factor: 4.506

9.  Evaluation of 4D CT acquisition methods designed to reduce artifacts.

Authors:  Sarah J Castillo; Richard Castillo; Edward Castillo; Tinsu Pan; Geoffrey Ibbott; Peter Balter; Brian Hobbs; Thomas Guerrero
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

10.  Comparing approaches to correct for respiratory motion in NH3 PET-CT cardiac perfusion imaging.

Authors:  Paul J Schleyer; Michael J O'Doherty; Sally F Barrington; Geraint Morton; Paul K Marsden
Journal:  Nucl Med Commun       Date:  2013-12       Impact factor: 1.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.