Literature DB >> 19251390

Assessment of accuracy and reliability in preoperative templating for hip resurfacing arthroplasty.

Michael Olsen1, Patrick Gamble, Mark Chiu, Nezar Tumia, Richard A Boyle, Emil H Schemitsch.   

Abstract

The current study investigated the accuracy and reliability of hip resurfacing component selection based on digital preoperative templating. Four surgeons made a template of preoperative radiographs on 2 occasions for acetabular and femoral components in 50 randomly selected hip resurfacing patients. Component selection reliability was variable among surgeons (kappa = 0.16-0.73) and fair between surgeons (kappa = 0.23-0.32). The average percentage of agreement for the acetabular component was 47% (range, 32%-64%) and for the femoral component was 54% (range, 38%-70%). Surgeons tended to underestimate implant size if the correct implant was not chosen (acetabular, 29%; femoral, 32%). Selection of an undersized femoral component may lead to femoral neck notching or varus implant alignment. This study emphasizes the need for intraoperative verification of preoperative templating results to ensure optimal implant selection in hip resurfacing. (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19251390     DOI: 10.1016/j.arth.2009.01.022

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Parastomal hernia: clinical and radiological definitions.

Authors:  A Jänes; L Weisby; L A Israelsson
Journal:  Hernia       Date:  2010-12-28       Impact factor: 4.739

2.  Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system.

Authors:  Ari Bertz; Kari Indrekvam; Mohamed Ahmed; Erling Englund; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2012-05-16       Impact factor: 2.199

3.  Radiological validation of a fluoroscopic guided technique for femoral implant positioning during hip resurfacing.

Authors:  Philippe Chiron; Régis Pailhé; Nicolas Reina; David Ancelin; Akash Sharma; Laurent Maubisson; Jean-Michel Laffosse
Journal:  Int Orthop       Date:  2013-01-29       Impact factor: 3.075

4.  Reliability and accuracy of digital templating for the humeral component of total shoulder arthroplasty.

Authors:  Christopher S Lee; Shane M Davis; Christianne J Lane; Ryan C Koonce; Andrew P Hartman; Kenneth Ball; James C Esch
Journal:  Shoulder Elbow       Date:  2014-09-07

5.  Design of custom-made navigational template of femoral head and pilot research in total hip resurfacing arthroplasty.

Authors:  Jinlong Liang; Yonghui Zhao; Xinjian Gao; Xuewei Fang; Yongqing Xu; Sheng Lu
Journal:  BMC Surg       Date:  2020-06-30       Impact factor: 2.102

6.  Determining the accuracy of preoperative total hip replacement 2D templating using the mediCAD® software.

Authors:  Seyed Peyman Mirghaderi; Sadula Sharifpour; Alireza Moharrami; Negar Ahmadi; Rangarirai Makuku; Maryam Salimi; Seyed Mohammad Javad Mortazavi
Journal:  J Orthop Surg Res       Date:  2022-04-10       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.