Literature DB >> 19231098

Potential dosimetric benefits of four-dimensional radiation treatment planning.

George Starkschall1, Keith Britton, Mary F McAleer, Melenda D Jeter, Michael R Kaus, Karl Bzdusek, Radhe Mohan, James D Cox.   

Abstract

PURPOSE: To determine the extent of dosimetric differences between conventional three-dimensional (3D) dose calculations and four-dimensional (4D) dose calculations based on deformation of organ models. METHODS AND MATERIALS: Four-dimensional dose calculations were retrospectively performed on computed tomography data sets for 15 patients with Stage III non-small-cell lung cancer, using a model-based deformable registration algorithm on a research version of a commercial radiation treatment planning system. Target volume coverage and doses to critical structures calculated using the 4D methodology were compared with those calculated using conventional 3D methodology.
RESULTS: For 11 of 15 patients, clinical target volume coverage was comparable in the 3D and 4D calculations, whereas for 7 of 15 patients, planning target volume coverage was comparable. For the other patients, the 4D calculation indicated a difference in target volume dose sufficiently great to warrant replanning. No correlations could be established between differences in 3D and 4D calculations and gross tumor volume size or extent of motion. Negligible differences were observed between 3D and 4D dose-volume relationships for normal anatomic structures.
CONCLUSIONS: Use of 4D dose calculations, when possible, helps ensure that target volumes will not be underirradiated when respiratory motion may affect the dose distribution.

Entities:  

Mesh:

Year:  2009        PMID: 19231098     DOI: 10.1016/j.ijrobp.2008.12.024

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  20 in total

1.  A novel technique to enable experimental validation of deformable dose accumulation.

Authors:  Carolyn J Niu; Warren D Foltz; Michael Velec; Joanne L Moseley; Adil Al-Mayah; Kristy K Brock
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

Review 2.  Magnetic resonance imaging in lung: a review of its potential for radiotherapy.

Authors:  Shivani Kumar; Gary Liney; Robba Rai; Lois Holloway; Daniel Moses; Shalini K Vinod
Journal:  Br J Radiol       Date:  2016-02-03       Impact factor: 3.039

3.  On correlated sources of uncertainty in four dimensional computed tomography data sets.

Authors:  Eric D Ehler; Wolfgang A Tome
Journal:  Technol Cancer Res Treat       Date:  2010-06

4.  4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines.

Authors:  Yugang Min; John Neylon; Amish Shah; Sanford Meeks; Percy Lee; Patrick Kupelian; Anand P Santhanam
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-01-14       Impact factor: 2.924

5.  Effect of breathing motion on radiotherapy dose accumulation in the abdomen using deformable registration.

Authors:  Michael Velec; Joanne L Moseley; Cynthia L Eccles; Tim Craig; Michael B Sharpe; Laura A Dawson; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-08-21       Impact factor: 7.038

6.  Dynamically accumulated dose and 4D accumulated dose for moving tumors.

Authors:  Heng Li; Yupeng Li; Xiaodong Zhang; Xiaoqiang Li; Wei Liu; Michael T Gillin; X Ronald Zhu
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

7.  Effects of respiratory motion on passively scattered proton therapy versus intensity modulated photon therapy for stage III lung cancer: are proton plans more sensitive to breathing motion?

Authors:  Jason Matney; Peter C Park; Jaques Bluett; Yi Pei Chen; Wei Liu; Laurence E Court; Zhongxing Liao; Heng Li; Radhe Mohan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-11-01       Impact factor: 7.038

8.  Evaluation of respiratory motion-corrected cone-beam CT at end expiration in abdominal radiotherapy sites: a prospective study.

Authors:  Russell E Kincaid; Agung E Hertanto; Yu-Chi Hu; Abraham J Wu; Karyn A Goodman; Hai D Pham; Ellen D Yorke; Qinghui Zhang; Qing Chen; Gig S Mageras
Journal:  Acta Oncol       Date:  2018-01-19       Impact factor: 4.089

9.  Patient-specific quantification of respiratory motion-induced dose uncertainty for step-and-shoot IMRT of lung cancer.

Authors:  Heng Li; Peter Park; Wei Liu; Jason Matney; Zhongxing Liao; Peter Balter; Yupeng Li; Xiaodong Zhang; Xiaoqiang Li; X Ronald Zhu
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

10.  Evaluation of 4D dose to a moving target with Monte Carlo dose calculation in stereotactic body radiotherapy for lung cancer.

Authors:  Kiyotomo Matsugi; Mitsuhiro Nakamura; Yuki Miyabe; Chikako Yamauchi; Yukinori Matsuo; Takashi Mizowaki; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2012-12-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.