Literature DB >> 19228090

In vivo validation of a three-dimensional optical method to document volumetric soft tissue changes of the interdental papilla.

Jan Strebel1, Andreas Ender, Frank Paqué, Michael Krähenmann, Thomas Attin, Patrick R Schmidlin.   

Abstract

BACKGROUND: Non-surgical and surgical periodontal treatment may cause volumetric changes in the gingival contour. Many techniques have been suggested to minimize soft tissue shrinkage; however, there is a lack of three-dimensional (3D) quantitative data comparing different treatment approaches. The aim of the present study was to clinically validate an easy-to-use chair-side procedure to document volumetric changes in the interdental papilla region.
METHODS: Nine volunteers participated in the study. A thin layer of a flowable composite resin material was applied on a papilla and volumetrically analyzed using the clinical chair-side computer-aided design/computer-aided machining (CAD/CAM) 3D method. To accurately measure the applied volumes, the composite resin volume was also determined using microcomputed tomography (micro-CT) and weight measurements. In addition, inter- and intraexaminer differences were evaluated in the same manner using a dental training unit (phantom head) to simulate clinical conditions.
RESULTS: No statistically significant difference was found between the results obtained by micro-CT and the weight measurements. The CAD/CAM 3D method showed a significant underestimation of the composite resin volume (P = 0.0047) compared to micro-CT, although the two methods correlated well (R(2) = 0.991). High accuracy was found when inter- and intraexaminer differences were evaluated, showing a concordance correlation coefficient of 0.99.
CONCLUSION: CAD/CAM 3D device and software are an easy-to-use chair-side method to document changes in soft tissues.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19228090     DOI: 10.1902/jop.2009.080288

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  6 in total

1.  Measurement accuracy of alveolar soft tissue contour using a laboratory laser scanner.

Authors:  Daisuke Ueno; Mariko Kobayashi; Kenko Tanaka; Tsuneaki Watanabe; Tetsuro Nakamura; Kazuhiko Ueda; Takatoshi Nagano
Journal:  Odontology       Date:  2017-08-02       Impact factor: 2.634

Review 2.  Potential of optical coherence tomography for early diagnosis of oral malignancies.

Authors:  Michael DeCoro; Petra Wilder-Smith
Journal:  Expert Rev Anticancer Ther       Date:  2010-03       Impact factor: 4.512

3.  Analysis of the embrasure dimensions between maxillary central incisors in relation to the topography of the interdental papilla.

Authors:  Sun-A Kim; Seung-Suk Choi; Soo-Jung Byun; Moontaek Chang
Journal:  J Periodontal Implant Sci       Date:  2011-12-31       Impact factor: 2.614

4.  The dome technique: a new surgical technique to enhance soft-tissue margins and emergence profiles around implants placed in the esthetic zone.

Authors:  Tassos Irinakis; Salwa Aldahlawi
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-14

5.  The accuracy and reliability of digital measurements of gingival recession versus conventional methods.

Authors:  Hytham N Fageeh; Abdullah A Meshni; Hassan A Jamal; Reghunathan S Preethanath; Esam Halboub
Journal:  BMC Oral Health       Date:  2019-07-16       Impact factor: 2.757

6.  Three-dimensional quantitative measurement of buccal augmented tissue with modified coronally advanced tunnel technique and de-epithelialized gingival graft: a prospective case series.

Authors:  Fei Xue; Rui Zhang; Yu Cai; Yong Zhang; Ni Kang; Qingxian Luan
Journal:  BMC Oral Health       Date:  2021-03-25       Impact factor: 2.757

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.