Literature DB >> 19218410

New electropositive filter for concentrating enteroviruses and noroviruses from large volumes of water.

Mohammad R Karim1, Eric R Rhodes, Nichole Brinkman, Larry Wymer, G Shay Fout.   

Abstract

The U.S. Environmental Protection Agency's information collection rule requires the use of 1MDS electropositive filters for concentrating enteric viruses from water, but unfortunately, these filters are not cost-effective for routine viral monitoring. In this study, an inexpensive electropositive cartridge filter, the NanoCeram filter, was evaluated for its ability to concentrate enteroviruses and noroviruses from large volumes of water. Seeded viruses were concentrated using the adsorption-elution procedure. The mean percent retention of seeded polioviruses by NanoCeram filters was 84%. To optimize the elution procedure, six protocols, each comprising two successive elutions with various lengths of filter immersion, were evaluated. The highest virus recovery (77%) was obtained by immersing the filters in beef extract for 1 minute during the first elution and for 15 min during the second elution. The recovery efficiencies of poliovirus, coxsackievirus B5, and echovirus 7 from 100-liter samples of seeded tap water were 54%, 27%, and 32%, respectively. There was no significant difference in virus recovery from tap water with a pH range of 6 to 9.5 and a water flow rate range of 5.5 liters/min to 20 liters/min. Finally, poliovirus and Norwalk virus recoveries by NanoCeram filters were compared to those by 1MDS filters, using tap water and Ohio River water. Poliovirus and Norwalk virus recoveries by NanoCeram filters from tap and river water were similar to or higher than those by the 1MDS filters. These data suggest that NanoCeram filters can be used as an inexpensive alternative to 1MDS filters for routine viral monitoring of water.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19218410      PMCID: PMC2675229          DOI: 10.1128/AEM.00922-08

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  31 in total

1.  An improved filter elution and cell culture assay procedure for evaluating public groundwater systems for culturable enteroviruses.

Authors:  Daniel R Dahling
Journal:  Water Environ Res       Date:  2002 Nov-Dec       Impact factor: 1.946

2.  Detection of noroviruses in tap water in Japan by means of a new method for concentrating enteric viruses in large volumes of freshwater.

Authors:  Eiji Haramoto; Hiroyuki Katayama; Shinichiro Ohgaki
Journal:  Appl Environ Microbiol       Date:  2004-04       Impact factor: 4.792

3.  Surveillance for waterborne-disease outbreaks associated with recreational water--United States, 2001-2002.

Authors:  Jonathan S Yoder; Brian G Blackburn; Gunther F Craun; Vincent Hill; Deborah A Levy; Nora Chen; Sherline H Lee; Rebecca L Calderon; Michael J Beach
Journal:  MMWR Surveill Summ       Date:  2004-10-22

4.  Concentration of enteroviruses, adenoviruses, and noroviruses from drinking water by use of glass wool filters.

Authors:  Elisabetta Lambertini; Susan K Spencer; Phillip D Bertz; Frank J Loge; Burney A Kieke; Mark A Borchardt
Journal:  Appl Environ Microbiol       Date:  2008-03-21       Impact factor: 4.792

5.  Surveillance for waterborne-disease outbreaks--United States, 1999-2000.

Authors:  Sherline H Lee; Deborah A Levy; Gunther F Craun; Michael J Beach; Rebecca L Calderon
Journal:  MMWR Surveill Summ       Date:  2002-11-22

6.  Outbreak of viral gastroenteritis due to drinking water contaminated by Norwalk-like viruses.

Authors:  M Kukkula; L Maunula; E Silvennoinen; C H von Bonsdorff
Journal:  J Infect Dis       Date:  1999-12       Impact factor: 5.226

7.  Concentration and detection of caliciviruses in water samples by reverse transcription-PCR.

Authors:  P W Huang; D Laborde; V R Land; D O Matson; A W Smith; X Jiang
Journal:  Appl Environ Microbiol       Date:  2000-10       Impact factor: 4.792

8.  Development of a virus concentration method and its application to detection of enterovirus and norwalk virus from coastal seawater.

Authors:  Hiroyuki Katayama; Akihiro Shimasaki; Shinichiro Ohgaki
Journal:  Appl Environ Microbiol       Date:  2002-03       Impact factor: 4.792

9.  A multiplex reverse transcription-PCR method for detection of human enteric viruses in groundwater.

Authors:  G Shay Fout; Beth C Martinson; Michael W N Moyer; Daniel R Dahling
Journal:  Appl Environ Microbiol       Date:  2003-06       Impact factor: 4.792

10.  Waterborne outbreak of gastroenteritis associated with a norovirus.

Authors:  Sandhya U Parshionikar; Sandra Willian-True; G Shay Fout; David E Robbins; Scott A Seys; Joslyn D Cassady; Richard Harris
Journal:  Appl Environ Microbiol       Date:  2003-09       Impact factor: 4.792

View more
  33 in total

1.  Real-time PCR detection of enteric viruses in source water and treated drinking water in Wuhan, China.

Authors:  Xiao Yan Ye; Xing Ming; Yong Lu Zhang; Wen Qing Xiao; Xia Ning Huang; Yu Guang Cao; Kang Ding Gu
Journal:  Curr Microbiol       Date:  2012-05-27       Impact factor: 2.188

2.  Characterization of a phosphotriesterase-like lactonase from Sulfolobus solfataricus and its immobilization for disruption of quorum sensing.

Authors:  Filomena S W Ng; Daniel M Wright; Stephen Y K Seah
Journal:  Appl Environ Microbiol       Date:  2010-12-23       Impact factor: 4.792

3.  Estimating virus occurrence using Bayesian modeling in multiple drinking water systems of the United States.

Authors:  Eunice A Varughese; Nichole E Brinkman; Emily M Anneken; Jennifer L Cashdollar; G Shay Fout; Edward T Furlong; Dana W Kolpin; Susan T Glassmeyer; Scott P Keely
Journal:  Sci Total Environ       Date:  2017-11-23       Impact factor: 7.963

4.  Development and validation of a concentration method for the detection of influenza a viruses from large volumes of surface water.

Authors:  Nathalie Deboosere; Srey Viseth Horm; Anthony Pinon; Jessica Gachet; Chloé Coldefy; Philippe Buchy; Michèle Vialette
Journal:  Appl Environ Microbiol       Date:  2011-04-15       Impact factor: 4.792

5.  New method using a positively charged microporous filter and ultrafiltration for concentration of viruses from tap water.

Authors:  Luisa A Ikner; Marcela Soto-Beltran; Kelly R Bright
Journal:  Appl Environ Microbiol       Date:  2011-03-25       Impact factor: 4.792

6.  A small volume procedure for viral concentration from water.

Authors:  Brian R McMinn; Asja Korajkic
Journal:  J Vis Exp       Date:  2015-02-03       Impact factor: 1.355

7.  Comparison of filters for concentrating microbial indicators and pathogens in lake water samples.

Authors:  Donna S Francy; Erin A Stelzer; Amie M G Brady; Carrie Huitger; Rebecca N Bushon; Hon S Ip; Michael W Ware; Eric N Villegas; Vicente Gallardo; H D Alan Lindquist
Journal:  Appl Environ Microbiol       Date:  2012-12-21       Impact factor: 4.792

Review 8.  Concentration and recovery of viruses from water: a comprehensive review.

Authors:  Luisa A Ikner; Charles P Gerba; Kelly R Bright
Journal:  Food Environ Virol       Date:  2012-05-31       Impact factor: 2.778

9.  Effectiveness of poliovirus concentration and recovery from treated wastewater by two electropositive filter methods.

Authors:  Marcela Soto-Beltran; Luisa A Ikner; Kelly R Bright
Journal:  Food Environ Virol       Date:  2013-02-08       Impact factor: 2.778

10.  Recovery of diverse microbes in high turbidity surface water samples using dead-end ultrafiltration.

Authors:  Bonnie Mull; Vincent R Hill
Journal:  J Microbiol Methods       Date:  2012-10-12       Impact factor: 2.363

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.