Literature DB >> 19211035

Reproducibility of BOLD signal change induced by breath holding.

Stefano Magon1, Gianpaolo Basso, Paolo Farace, Giuseppe Kenneth Ricciardi, Alberto Beltramello, Andrea Sbarbati.   

Abstract

Blood oxygen level dependent (BOLD) contrast is influenced by some physiological factors such as blood flow and blood volume that can be a source of variability in fMRI analysis. Previous studies proposed to use the cerebrovascular response data to normalize or calibrate BOLD maps in order to reduce variability of fMRI data both among brain areas in single subject analysis and across subjects. Breath holding is one of the most widely used methods to investigate the vascular reactivity. However, little is known about the robustness and reproducibility of this procedure. In this study we investigated three different breath holding periods. Subjects were asked to hold their breath for 9, 15 or 21 s in three separate runs and the fMRI protocol was repeated after 15 to 20 days. Our data show that the BOLD response to breath holding after inspiration results in a complex shape due to physiological factors that influence the signal variation with a timing that is highly reproducible. Nevertheless, the reproducibility of the magnitude of the cerebrovascular response to CO(2), expressed as amplitude of BOLD signal and number of responding voxels, strongly depends on duration of breath holding periods. Breath holding period of 9 s results in high variability of the magnitude of the response while longer breath holding durations produce more robust and reproducible BOLD responses.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19211035     DOI: 10.1016/j.neuroimage.2008.12.059

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  29 in total

1.  Clinical utility of cerebrovascular reactivity mapping in patients with low grade gliomas.

Authors:  Jay J Pillai; Domenico Zacá
Journal:  World J Clin Oncol       Date:  2011-12-10

2.  Localization of the hand motor area by arterial spin labeling and blood oxygen level-dependent functional magnetic resonance imaging.

Authors:  Marco A F Pimentel; Pedro Vilela; Inês Sousa; Patrícia Figueiredo
Journal:  Hum Brain Mapp       Date:  2011-11-28       Impact factor: 5.038

3.  Breath hold effect on cardiovascular brain pulsations - A multimodal magnetic resonance encephalography study.

Authors:  Lauri Raitamaa; Vesa Korhonen; Niko Huotari; Ville Raatikainen; Taneli Hautaniemi; Janne Kananen; Aleksi Rasila; Heta Helakari; Aleksandra Zienkiewicz; Teemu Myllylä; Viola Borchardt; Vesa Kiviniemi
Journal:  J Cereb Blood Flow Metab       Date:  2018-09-11       Impact factor: 6.200

Review 4.  Cerebrovascular reactivity mapping: an evolving standard for clinical functional imaging.

Authors:  J J Pillai; D J Mikulis
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-30       Impact factor: 3.825

5.  Cerebrovascular reactivity mapping in patients with low grade gliomas undergoing presurgical sensorimotor mapping with BOLD fMRI.

Authors:  Domenico Zacà; Jorge Jovicich; Sreenivasan R Nadar; James T Voyvodic; Jay J Pillai
Journal:  J Magn Reson Imaging       Date:  2013-11-04       Impact factor: 4.813

6.  Cerebrovascular reactivity in young subjects with sleep apnea.

Authors:  John Buterbaugh; Charles Wynstra; Natalie Provencio; Daniel Combs; Michael Gilbert; Sairam Parthasarathy
Journal:  Sleep       Date:  2015-02-01       Impact factor: 5.849

7.  Cerebrovascular reactivity mapping using intermittent breath modulation.

Authors:  Peiying Liu; Cuimei Xu; Zixuan Lin; Sandeepa Sur; Yang Li; Sevil Yasar; Paul Rosenberg; Marilyn Albert; Hanzhang Lu
Journal:  Neuroimage       Date:  2020-04-08       Impact factor: 6.556

8.  Evaluation of cerebrovascular reserve in patients with cerebrovascular diseases using resting-state MRI: A feasibility study.

Authors:  Kamil Taneja; Hanzhang Lu; Babu G Welch; Binu P Thomas; Marco Pinho; Doris Lin; Argye E Hillis; Peiying Liu
Journal:  Magn Reson Imaging       Date:  2019-03-05       Impact factor: 2.546

Review 9.  Cerebrovascular reactivity (CVR) MRI with CO2 challenge: A technical review.

Authors:  Peiying Liu; Jill B De Vis; Hanzhang Lu
Journal:  Neuroimage       Date:  2018-03-21       Impact factor: 6.556

10.  Quantitative mapping of cerebrovascular reactivity using resting-state BOLD fMRI: Validation in healthy adults.

Authors:  Ali M Golestani; Luxi L Wei; J Jean Chen
Journal:  Neuroimage       Date:  2016-05-11       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.