Literature DB >> 19209342

Computation of transient flow rates in passive pumping micro-fluidic systems.

I-Jane Chen1, Eugene C Eckstein, Erno Lindner.   

Abstract

Motion in micro-channels of passive flow micro-fluidic systems can be controlled by proper design and estimated by careful modeling. We report on methods to describe the flow rate as function of time in a passive pump driven micro-fluidic system. The model considers the surface energy present in small droplets, which prompts their shrinkage and induces flow. The droplet geometries are controlled by the micro-fluidic system geometry and hydrophilicity of the droplet channel contact area so that the chord of the droplet's cross section is restrained as the fluid is pumped. The model uses interfacial thermodynamics and the Hagen-Poiseuille equation for calculating the flow rate in micro-channels. Existing analyses consider the theoretical relationships among sample volume and induced flow rate, surface energy of the drops at the entrance and exit ports, and the resistance to flow. This model provides more specific information on the influence of the experimental conditions in computations of the flow rate. The model was validated in four sets of experiments. Passive pumps with 1.8 mm diameter, hydrophobic or hydrophilic entry ports, 5.0 or 10.0 mm channel length, and 2.5 or 3.3 mm diameter reservoir ports provided initial flow rates between 85 nL s(-1) and 196 nL s(-1).

Entities:  

Mesh:

Year:  2008        PMID: 19209342      PMCID: PMC2941346          DOI: 10.1039/b808660e

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  8 in total

Review 1.  Zeta potential of microfluidic substrates: 1. Theory, experimental techniques, and effects on separations.

Authors:  Brian J Kirby; Ernest F Hasselbrink
Journal:  Electrophoresis       Date:  2004-01       Impact factor: 3.535

2.  A passive pumping method for microfluidic devices.

Authors:  Glenn M Walker; David J Beebe
Journal:  Lab Chip       Date:  2002-08-05       Impact factor: 6.799

Review 3.  Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies.

Authors:  Samuel K Sia; George M Whitesides
Journal:  Electrophoresis       Date:  2003-11       Impact factor: 3.535

4.  Flow rate analysis of a surface tension driven passive micropump.

Authors:  Erwin Berthier; David J Beebe
Journal:  Lab Chip       Date:  2007-07-30       Impact factor: 6.799

5.  The stability of radio-frequency plasma-treated polydimethylsiloxane surfaces.

Authors:  I-Jane Chen; Ernö Lindner
Journal:  Langmuir       Date:  2007-02-06       Impact factor: 3.882

6.  Nanoliter liquid metering in microchannels using hydrophobic patterns

Authors: 
Journal:  Anal Chem       Date:  2000-09-01       Impact factor: 6.986

7.  An integrated nanoliter DNA analysis device.

Authors:  M A Burns; B N Johnson; S N Brahmasandra; K Handique; J R Webster; M Krishnan; T S Sammarco; P M Man; D Jones; D Heldsinger; C H Mastrangelo; D T Burke
Journal:  Science       Date:  1998-10-16       Impact factor: 47.728

8.  Electrochemical principles for active control of liquids on submillimeter scales

Authors: 
Journal:  Science       Date:  1999-01-01       Impact factor: 47.728

  8 in total
  9 in total

Review 1.  Fundamentals of microfluidic cell culture in controlled microenvironments.

Authors:  Edmond W K Young; David J Beebe
Journal:  Chem Soc Rev       Date:  2010-02-01       Impact factor: 54.564

2.  A microfluidic cell concentrator.

Authors:  Jay Warrick; Ben Casavant; Megan Frisk; David Beebe
Journal:  Anal Chem       Date:  2010-10-01       Impact factor: 6.986

3.  Novel, Emerging Chip Models of the Blood-Brain Barrier and Future Directions.

Authors:  Paul M Holloway
Journal:  Methods Mol Biol       Date:  2022

4.  Passive microfluidic pumping using coupled capillary/evaporation effects.

Authors:  N Scott Lynn; David S Dandy
Journal:  Lab Chip       Date:  2009-10-05       Impact factor: 6.799

5.  Lab-on-chip flow injection analysis system without an external pump and valves and integrated with an in line electrochemical detector.

Authors:  I-Jane Chen; Ernö Lindner
Journal:  Anal Chem       Date:  2009-12-15       Impact factor: 6.986

6.  A Microfluidic Passive Pumping Coulter Counter.

Authors:  Amy L McPherson; Glenn M Walker
Journal:  Microfluid Nanofluidics       Date:  2010-10-01       Impact factor: 2.529

Review 7.  Advances in passively driven microfluidics and lab-on-chip devices: a comprehensive literature review and patent analysis.

Authors:  Vigneswaran Narayanamurthy; Z E Jeroish; K S Bhuvaneshwari; Pouriya Bayat; R Premkumar; Fahmi Samsuri; Mashitah M Yusoff
Journal:  RSC Adv       Date:  2020-03-23       Impact factor: 4.036

8.  Effect of wetting on capillary pumping in microchannels.

Authors:  Arman Javadi; Mehdi Habibi; Fereshte Samadi Taheri; Sébastien Moulinet; Daniel Bonn
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

Review 9.  Novel roles for well-known players: from tobacco mosaic virus pests to enzymatically active assemblies.

Authors:  Claudia Koch; Fabian J Eber; Carlos Azucena; Alexander Förste; Stefan Walheim; Thomas Schimmel; Alexander M Bittner; Holger Jeske; Hartmut Gliemann; Sabine Eiben; Fania C Geiger; Christina Wege
Journal:  Beilstein J Nanotechnol       Date:  2016-04-25       Impact factor: 3.649

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.