Variability in sublingual microvessel density and flow measurements in healthy volunteers.

Sheena M A Hubble1, Hayley L Kyte, Kim Gooding, Angela C Shore.   

Abstract

OBJECTIVES: As sublingual microvascular indices are increasingly heralded as new resuscitation end-points, better population data are required to power clinical studies. This paper describes improved methods to quantify sublingual microvessel flow and density in images obtained by sidestream dark field (SDF) technology in healthy volunteers, including vessels under 10 microm in diameter.
MATERIALS AND METHODS: Measurements of sublingual capillary density and flow were obtained by recording three 15-second images in 20 healthy volunteers over three days. Two independent observers quantified capillary density by using two methods: total vessel length (mm/mm2) and counting (number/mm). Both intraoral and temporal variabilities within subject and observer reproducibilities were determined by using coefficients of variability and reproducibility indices.
RESULTS: For small (1-10 microm), medium (11-20 microm), and large (21-50 microm) diameter, mean vessel density with standard deviations (SDs) in volunteers was 21.3(+/- 4.9), 5.2 (+/- 1.2), and 2.7 (+/- 0.9) mm/mm2, respectively. Also, 94.0 +/- 1.4% of small vessels, 94.5 +/- 1.4% of medium vessels, and 94.5+/- 4.0% of large vessels had continuous perfusion. Within subjects, the means of all measurements over three days varied less than 13, 22, and 35% in small, medium, and large vessels, respectively. Interobserver reproducibility was good, especially for capillary (1-10 microm) density and flow measurements.
CONCLUSIONS: Our methods of microvessel flow and density quantification have low observer variability and confirm the stability of microcirculatory measurements over time. These results facilitate the development of SDF-acquired sublingual microvascular indices as feasible microperfusion markers in shock resuscitation.

Entities:  

Mesh:

Year:  2009        PMID: 19206003     DOI: 10.1080/10739680802461935

Source DB:  PubMed          Journal:  Microcirculation        ISSN: 1073-9688            Impact factor:   2.628


  12 in total

1.  Ability and efficiency of an automatic analysis software to measure microvascular parameters.

Authors:  Andrea Carsetti; Hollmann D Aya; Silvia Pierantozzi; Simone Bazurro; Abele Donati; Andrew Rhodes; Maurizio Cecconi
Journal:  J Clin Monit Comput       Date:  2016-09-01       Impact factor: 2.502

2.  Sublingual microcirculation in pulmonary arterial hypertension.

Authors:  Luma Dababneh; Frank Cikach; Laith Alkukhun; Raed A Dweik; Adriano R Tonelli
Journal:  Ann Am Thorac Soc       Date:  2014-05

3.  Improvement of sidestream dark field imaging with an image acquisition stabilizer.

Authors:  Gianmarco M Balestra; Rick Bezemer; E Christiaan Boerma; Ze-Yie Yong; Krishan D Sjauw; Annemarie E Engstrom; Matty Koopmans; Can Ince
Journal:  BMC Med Imaging       Date:  2010-07-13       Impact factor: 1.930

4.  Dose-dependent benefit of nitroglycerin on microcirculation of patients with severe heart failure.

Authors:  Corstiaan A den Uil; Kadir Caliskan; Wim K Lagrand; Martin van der Ent; Lucia S D Jewbali; Jan P van Kuijk; Peter E Spronk; Maarten L Simoons
Journal:  Intensive Care Med       Date:  2009-07-29       Impact factor: 17.440

5.  Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine.

Authors:  Can Ince; E Christiaan Boerma; Maurizio Cecconi; Daniel De Backer; Nathan I Shapiro; Jacques Duranteau; Michael R Pinsky; Antonio Artigas; Jean-Louis Teboul; Irwin K M Reiss; Cesar Aldecoa; Sam D Hutchings; Abele Donati; Marco Maggiorini; Fabio S Taccone; Glenn Hernandez; Didier Payen; Dick Tibboel; Daniel S Martin; Alexander Zarbock; Xavier Monnet; Arnaldo Dubin; Jan Bakker; Jean-Louis Vincent; Thomas W L Scheeren
Journal:  Intensive Care Med       Date:  2018-02-06       Impact factor: 17.440

6.  Study Design of the Microcirculatory Shock Occurrence in Acutely Ill Patients (microSOAP): an International Multicenter Observational Study of Sublingual Microcirculatory Alterations in Intensive Care Patients.

Authors:  Namkje A R Vellinga; E Christiaan Boerma; Matty Koopmans; Abele Donati; Arnaldo Dubin; Nathan I Shapiro; Rupert M Pearse; Jan Bakker; Can Ince
Journal:  Crit Care Res Pract       Date:  2012-05-14

7.  Design and feasibility of "PREMATurity as predictor of children's Cardiovascular-renal Health" (PREMATCH): A pilot study.

Authors:  Anke Raaijmakers; Thibault Petit; Yumei Gu; Zhenyu Zhang; Fangfei Wei; Bjorn Cools; Lotte Jacobs; Lutgarde Thijs; Liesbeth Thewissen; Elena Levtchenko; Jan A Staessen; Karel Allegaert
Journal:  Blood Press       Date:  2015-06-24       Impact factor: 2.835

8.  Reproducibility of sublingual microcirculation parameters obtained from sidestream darkfield imaging.

Authors:  Luca Valerio; Ron J Peters; Aeilko H Zwinderman; Sara-Joan Pinto-Sietsma
Journal:  PLoS One       Date:  2019-03-14       Impact factor: 3.240

9.  Cytocam-IDF (incident dark field illumination) imaging for bedside monitoring of the microcirculation.

Authors:  Guclu Aykut; Gerke Veenstra; Claudia Scorcella; Can Ince; Christiaan Boerma
Journal:  Intensive Care Med Exp       Date:  2015-01-31

10.  Conventional hemodynamic resuscitation may fail to optimize tissue perfusion: an observational study on the effects of dobutamine, enoximone, and norepinephrine in patients with acute myocardial infarction complicated by cardiogenic shock.

Authors:  Corstiaan A den Uil; Wim K Lagrand; Martin van der Ent; Koen Nieman; Ard Struijs; Lucia S D Jewbali; Alina A Constantinescu; Peter E Spronk; Maarten L Simoons
Journal:  PLoS One       Date:  2014-08-01       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.