Literature DB >> 19194289

Energy reflectance and tympanometry in normal and otosclerotic ears.

Navid Shahnaz1, Karin Bork, Linda Polka, Neil Longridge, Desmond Bell, Brian D Westerberg.   

Abstract

OBJECTIVE: The major goal of this study was to examine differences in the middle ear mechano-acoustical properties of normal ears and ears with surgically confirmed otosclerosis using conventional and multifrequency tympanometry (MFT) as well as energy reflectance (ER). Second, we sought to compare ER, standard tympanometry, and MFT in their ability to distinguish healthy and otosclerotic ears examining both overall test performance (sensitivity and specificity) and receiver- operating characteristic analyses.
DESIGN: Sixty-two normal-hearing adults and 28 patients diagnosed with otosclerosis served as subjects. Tympanometric data were gathered on a clinical immittance machine, the Virtual 310 equipped with a high-frequency option. Two of the parameters, static admittance and tympanometric width, were measured automatically at a standard 226 Hz frequency. The remaining two parameters, resonant frequency and frequency corresponding to admittance phase angle of 45 degree (F45 degrees ), were derived from MFT, multicomponent tympanometry, using a mathematical approach similar to the method used in GSI Tympstar Version 2. ER data were gathered using Mimosa Acoustics (RMS-system v4.0.4.4) equipment.
RESULTS: Analyses of receiver-operating characteristic plots confirmed the advantage of MFT measures of resonant frequency and F45 degrees over the standard low-frequency measures of static admittance and tympanometric width with respect to distinguishing otosclerotic ears from normal ears. The F45 degrees measure was also found to be the best single index for making this distinction among tympanometric parameters. ER less than 1 kHz was significantly higher in otosclerotic ears than normal ears. This indicates that most of the incident energy below 1 kHz is reflected back into the ear canal in otosclerotic ears. ER patterns exceeding the 90th percentile of the normal ears across all frequencies correctly identify 82% of the otosclerotic ears while maintaining a low false alarm rate (17.2%); thus, this measure outperforms the other individual tympanometric parameters. Combination of ER and F45 degrees were able to distinguish all otosclerotic ears. Correlations and the individual patterns of test performance revealed that information provided by ER is supplemental to the information provided by conventional and MFT with respect to distinguishing otosclerotic ears from normal ears.
CONCLUSION: The present findings show that the overall changes of ER across frequencies can distinguish otosclerotic ears from normal ears and from other sources of conductive hearing loss. Incorporating ER in general practice will improve the identification of otosclerotic ears when conventional tympanometry and MFT may fail to do so. To further improve the false alarm rate, ER should be interpreted in conjunction with other audiologic test batteries because it is unlikely that signs of a conductive component, including abnormal middle ear muscle reflex and ER responses, would be observed in an ear with normal middle ear function.

Entities:  

Mesh:

Year:  2009        PMID: 19194289     DOI: 10.1097/AUD.0b013e3181976a14

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  23 in total

1.  Non-invasive estimation of middle-ear input impedance and efficiency.

Authors:  James D Lewis; Stephen T Neely
Journal:  J Acoust Soc Am       Date:  2015-08       Impact factor: 1.840

2.  Wideband absorbance tympanometry: a novel method in identifying otosclerosis.

Authors:  Arunraj Karuppannan; Animesh Barman
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-01-03       Impact factor: 2.503

3.  Factors affecting sound energy absorbance in acute otitis media model of chinchilla.

Authors:  Xiying Guan; Thomas W Seale; Rong Z Gan
Journal:  Hear Res       Date:  2017-04-10       Impact factor: 3.208

4.  Wideband acoustic transfer functions predict middle-ear effusion.

Authors:  John C Ellison; Michael Gorga; Edward Cohn; Denis Fitzpatrick; Chris A Sanford; Douglas H Keefe
Journal:  Laryngoscope       Date:  2012-02-28       Impact factor: 3.325

5.  Controlled exploration of the effects of conductive hearing loss on wideband acoustic immittance in human cadaveric preparations.

Authors:  Gabrielle R Merchant; Saumil N Merchant; John J Rosowski; Hideko Heidi Nakajima
Journal:  Hear Res       Date:  2016-08-03       Impact factor: 3.208

6.  Effects of middle-ear disorders on power reflectance measured in cadaveric ear canals.

Authors:  Susan E Voss; Gabrielle R Merchant; Nicholas J Horton
Journal:  Ear Hear       Date:  2012 Mar-Apr       Impact factor: 3.570

7.  Effect of Middle-Ear Pathology on High-Frequency Ear Canal Reflectance Measurements in the Frequency and Time Domains.

Authors:  Gabrielle R Merchant; Jonathan H Siegel; Stephen T Neely; John J Rosowski; Hideko H Nakajima
Journal:  J Assoc Res Otolaryngol       Date:  2019-10-31

8.  Procedures for ambient-pressure and tympanometric tests of aural acoustic reflectance and admittance in human infants and adults.

Authors:  Douglas H Keefe; Lisa L Hunter; M Patrick Feeney; Denis F Fitzpatrick
Journal:  J Acoust Soc Am       Date:  2015-12       Impact factor: 1.840

9.  Investigation of bacterial biofilm in the human middle ear using optical coherence tomography and acoustic measurements.

Authors:  Cac T Nguyen; Sarah R Robinson; Woonggyu Jung; Michael A Novak; Stephen A Boppart; Jont B Allen
Journal:  Hear Res       Date:  2013-04-12       Impact factor: 3.208

10.  Wideband aural acoustic absorbance predicts conductive hearing loss in children.

Authors:  Douglas H Keefe; Chris A Sanford; John C Ellison; Denis F Fitzpatrick; Michael P Gorga
Journal:  Int J Audiol       Date:  2012-10-16       Impact factor: 2.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.