Literature DB >> 19182699

Diurnal variation of corneal shape and thickness.

Scott A Read1, Michael J Collins.   

Abstract

PURPOSE: To investigate associations between the diurnal variation in a range of corneal parameters, including anterior and posterior corneal topography, and regional corneal thickness.
METHODS: Fifteen subjects had their corneas measured using a rotating Scheimpflug camera (Pentacam) every 3 to 7 h over a 24-h period. Anterior and posterior corneal axial curvature, pachymetry and anterior chamber depth were analyzed. The best fitting corneal sphero-cylinder from the axial curvature, and the average corneal thickness for a series of different corneal regions were calculated. Measures of intraocular pressure and axial length were also taken at each measurement session.
RESULTS: Significant diurnal variation was found to occur in both the anterior and posterior corneal curvature and in the regional corneal thickness. Flattening of the anterior corneal best sphere was observed at the early morning measurement upon waking (p < 0.0001). The posterior cornea also underwent a significant steepening (p < 0.0001) and change in astigmatism 90/180 degrees at this time. A significant swelling of the cornea (p < 0.0001) was also evident upon waking. Highly significant associations were found between the diurnal variation in corneal thickness and the changes in corneal curvature.
CONCLUSIONS: Small but significant diurnal variation occurs in the regional thickness and the shape of the anterior and posterior cornea. The largest changes in the cornea are typically evident upon waking. The regional corneal swelling observed at this time was not uniform, being slightly greater in peripheral corneal regions. The pattern of corneal swelling evident on waking resulted in a steepening of the posterior, and a flattening of the anterior corneal surface.

Entities:  

Mesh:

Year:  2009        PMID: 19182699     DOI: 10.1097/OPX.0b013e3181981b7e

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  29 in total

1.  Evaluation of topographic, tomographic, topometric, densitometric, and aberrometric features of cornea with pentacam HR system in subclinical keratoconus.

Authors:  Haci Hasan Ozkan; Mustafa Koc; Hasan Kiziltoprak; Kemal Tekin; Emre Aydemir
Journal:  Int Ophthalmol       Date:  2021-03-27       Impact factor: 2.031

2.  Fuchs' corneal dystrophy.

Authors:  Allen O Eghrari; John D Gottsch
Journal:  Expert Rev Ophthalmol       Date:  2010-04

3.  South African Eye Study (SAES): ethnic differences in central corneal thickness and intraocular pressure.

Authors:  S O Baboolal; D P Smit
Journal:  Eye (Lond)       Date:  2018-01-12       Impact factor: 3.775

4.  Evaluation of rebound tonometry in non-human primates.

Authors:  Elizabeth J Elsmo; Julie A Kiland; Paul L Kaufman; Gillian J McLellan
Journal:  Exp Eye Res       Date:  2011-02-16       Impact factor: 3.467

5.  Crab claw pattern on corneal topography: pellucid marginal degeneration or inferior keratoconus?

Authors:  M Koc; K Tekin; M Inanc; P Kosekahya; P Yilmazbas
Journal:  Eye (Lond)       Date:  2017-09-22       Impact factor: 3.775

6.  Melatonin Entrains PER2::LUC Bioluminescence Circadian Rhythm in the Mouse Cornea.

Authors:  Kenkichi Baba; Alec J Davidson; Gianluca Tosini
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-07       Impact factor: 4.799

7.  Comprehensive Analysis Identified the Circadian Clock and Global Circadian Gene Expression in Human Corneal Endothelial Cells.

Authors:  Hiroko Nakai; Yoshiki Tsuchiya; Nobuya Koike; Taiki Asano; Morio Ueno; Yasuhiro Umemura; Yuh Sasawaki; Ryutaro Ono; Junji Hamuro; Chie Sotozono; Kazuhiro Yagita
Journal:  Invest Ophthalmol Vis Sci       Date:  2022-05-02       Impact factor: 4.925

8.  Ocular Biometric Diurnal Rhythms in Emmetropic and Myopic Adults.

Authors:  Hannah J Burfield; Nimesh B Patel; Lisa A Ostrin
Journal:  Invest Ophthalmol Vis Sci       Date:  2018-10-01       Impact factor: 4.799

9.  Changes in intraocular pressure after pharmacologic pupil dilation.

Authors:  Joon Mo Kim; Ki Ho Park; So Young Han; Kwan Soo Kim; Dong Myung Kim; Tae Woo Kim; Joseph Caprioli
Journal:  BMC Ophthalmol       Date:  2012-09-27       Impact factor: 2.209

10.  Central and midperipheral corneal thickness measured with Scheimpflug imaging and optical coherence tomography.

Authors:  Jinhai Huang; Xixia Ding; Giacomo Savini; Zhengxuan Jiang; Chao Pan; Yanjun Hua; Fan Wu; Yifan Feng; Ye Yu; Qinmei Wang
Journal:  PLoS One       Date:  2014-05-22       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.