Literature DB >> 19182321

Ultra fast electromagnetic field computations for RF multi-transmit techniques in high field MRI.

Bob van den Bergen1, Christiaan C Stolk, Jan Bouwe van den Berg, Jan J W Lagendijk, Cornelis A T Van den Berg.   

Abstract

A new, very fast, approach for calculations of the electromagnetic excitation field for MRI is presented. The calculation domain is divided in different homogeneous regions, where for each region a general solution is obtained by a summation of suitable basis functions. A unique solution for the electromagnetic field is found by enforcing the appropriate boundary conditions between the different regions. The method combines the speed of an analytical method with the versatility of full wave simulation methods and is validated in the pelvic region against FDTD simulations at 3 and 7 T and measurements at 3 T. The high speed and accurate reproduction of measurements and FDTD calculations are believed to offer large possibilities for multi-transmit applications, where it can be used for on-line control of the global and local electric field and specific absorption rate (SAR) in the patient. As an example the method was evaluated for RF shimming with the use of 7 T simulation results, where it was demonstrated that the magnetic excitation field could be homogenized, while both the local and average SAR were reduced by 38% or more.

Entities:  

Mesh:

Year:  2009        PMID: 19182321     DOI: 10.1088/0031-9155/54/5/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Automated gradient-based electrical properties tomography in the human brain using 7 Tesla MRI.

Authors:  Yicun Wang; Pierre-Francois Van de Moortele; Bin He
Journal:  Magn Reson Imaging       Date:  2019-08-16       Impact factor: 2.546

2.  Effect of parallel radiofrequency transmission on arterial input function selection in dynamic contrast-enhanced 3 Tesla pelvic MRI.

Authors:  Hatim Chafi; Saba N Elias; Huyen T Nguyen; Harry T Friel; Michael V Knopp; BeiBei Guo; Steven B Heymsfield; Guang Jia
Journal:  J Magn Reson Imaging       Date:  2015-06-09       Impact factor: 4.813

3.  Design and application of combined 8-channel transmit and 10-channel receive arrays and radiofrequency shimming for 7-T shoulder magnetic resonance imaging.

Authors:  Ryan Brown; Cem Murat Deniz; Bei Zhang; Gregory Chang; Daniel K Sodickson; Graham C Wiggins
Journal:  Invest Radiol       Date:  2014-01       Impact factor: 6.016

4.  Comparison between eight- and sixteen-channel TEM transceive arrays for body imaging at 7 T.

Authors:  C J Snyder; L Delabarre; S Moeller; J Tian; C Akgun; P-F Van de Moortele; P J Bolan; K Ugurbil; J T Vaughan; G J Metzger
Journal:  Magn Reson Med       Date:  2011-11-18       Impact factor: 4.668

5.  Local specific absorption rate in high-pass birdcage and transverse electromagnetic body coils for multiple human body models in clinical landmark positions at 3T.

Authors:  Desmond T B Yeo; Zhangwei Wang; Wolfgang Loew; Mika W Vogel; Ileana Hancu
Journal:  J Magn Reson Imaging       Date:  2011-05       Impact factor: 4.813

6.  Simultaneous imaging of in vivo conductivity and susceptibility.

Authors:  Dong-Hyun Kim; Narae Choi; Sung-Min Gho; Jaewook Shin; Chunlei Liu
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

7.  B1-based SAR reconstruction using contrast source inversion-electric properties tomography (CSI-EPT).

Authors:  Edmond Balidemaj; Cornelis A T van den Berg; Astrid L H M W van Lier; Aart J Nederveen; Lukas J A Stalpers; Hans Crezee; Rob F Remis
Journal:  Med Biol Eng Comput       Date:  2016-04-23       Impact factor: 2.602

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.