Literature DB >> 19170776

Evaluation of Ves-Matic Cube 200--an automated system for the measurement of the erythrocyte sedimentation rate.

E Perovic1, L Bakovic, A Valcic.   

Abstract

Ves-Matic Cube 200 is fully automated analyzer that performs erythrocyte sedimentation rate (ESR) measurement using the standard ethylenediaminetetraacetic acid blood sample tube, thus markedly reducing the analytical time and avoiding the need for an extra blood sample. The aim of this study was to assess the automatic Ves-Matic Cube 200 system for the measurement of ESR in comparison with the original International Council for Standardization in Hematology reference method (Westergren). The evaluation comprised accuracy which was established using a 95% confidence interval (CI) for the mean difference between Ves-Matic Cube 200 and Westergren method (mean of difference: 0.47+/-6.84 mm/h; 95% CI: -0.376 to 1.325 mm/h), within-run imprecision for samples with ESR values of 9, 42 and 95 mm/h (coefficients of variation: 9.19%, 13.88% and 5.66%, respectively) and method comparison (rho=0.95; Passing-Bablok regression equation: Y=-0.0435+1.0435 X; bias: -0.5; limits of agreement: -13.9 to 12.9). Stability was estimated after 24 h storage either at 4 degrees C and room temperature (mean of differences: -1.91 mm/h; 95% CI: -4.852 to 1.037 mm/h and mean of differences: -12.48 mm/h; 95% CI: -16.580 to -8.390 mm/h, respectively). The obtained results suggest that the Ves-Matic Cube 200 automated analyzer is reliable system for the measurement of ESR in clinical laboratories.

Entities:  

Mesh:

Year:  2009        PMID: 19170776     DOI: 10.1111/j.1751-553X.2008.01135.x

Source DB:  PubMed          Journal:  Int J Lab Hematol        ISSN: 1751-5521            Impact factor:   2.877


  5 in total

1.  Evaluation of Ves-Matic Cube 200 for erythrocyte sedimentation rate determination.

Authors:  Sevilay Sezer; Fatma Meriç Yilmaz; Oğuzhan Kaya; Sema Uysal
Journal:  J Clin Lab Anal       Date:  2013-09       Impact factor: 2.352

2.  Erythrocyte sedimentation rate measurement by VES Matic Cube 80 in relation to inflammation plasma proteins.

Authors:  Helena Cerutti; Chiara Muzzi; Roberto Leoncini; Carlo Scapellato; Alessio Cortelazzo; Emiliano Furlani; Roberto Guerranti
Journal:  J Clin Lab Anal       Date:  2011       Impact factor: 2.352

3.  Differences in erythrocyte sedimentation rates using a modified Westergren method and an alternate method.

Authors:  Elise Schapkaitz; Shilla RabuRabu; Marcel Engelbrecht
Journal:  J Clin Lab Anal       Date:  2018-08-26       Impact factor: 2.352

4.  Comparison of iSED and Ves-Matic Cube 200 Erythrocyte Sedimentation Rate Measurements With Westergren Method.

Authors:  Nihal Boğdaycioğlu; Fatma Meric Yilmaz; Sevilay Sezer; Esra Oğuz
Journal:  J Clin Lab Anal       Date:  2014-08-17       Impact factor: 2.352

5.  Parameter Evaluation and Application Demonstration of a New Type of Blood Vacuum Tube Cap Opening and Closing Machine.

Authors:  Rong Pu; Meicen Pu; Qingsong Xin; Feng Chen
Journal:  Iran J Public Health       Date:  2019-09       Impact factor: 1.429

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.