Literature DB >> 19163097

Towards a microcoil for intracranial and intraductal MR microscopy.

Debra S Strick1, Ray L Nunnally, Jolinda C Smith, W Clark, Dixie J Mills, Mark S Cohen, Jack W Judy.   

Abstract

Implantable RF-coils have enabled sub-mm resolution magnetic resonance images (MRI) of deep structures. Scaling down the size of RF coils has similarly provided a gain in signal-to-noise ratio in nuclear-magnetic-resonance spectroscopy. By combining both approaches we designed, fabricated, and imaged with an implantable microcoil catheter. While typical implantable catheters use a transverse magnetization, the axial magnetization of the microcoil provides improved sensitivity and allows visualization of the tissue beyond the distal end of the catheter. The microcoil catheter was designed with a diameter of 1 mm for future integration with intracranial devices, and for intraductal use in breast oncology. We modified the NMR-microcoil design to allow implantation of the RF coil, by winding the microcoil on medical-grade silicone tubing and incorporating leads on the catheter to connect circuit components. In order to achieve proper turn spacing, we coated copper wire with 25 microm of biocompatible polymer (Parylene C). Tuning and matching circuitry insured that the impedance of the RF coil was approximately 50 ohm at the operating frequency for 3-T proton MR applications. A duplexer was used to enable use of the microcoil catheter as a transceiver. Experimental verification of the coil design was achieved through ex vivo imaging of neural tissue. As expected, the microcoil catheter provided microscale images with 20-microm in-plane-resolution and 170-microm-thick slices. While 3-T MRI typically provides 1 to 30 voxels per-cubic-millimeter, in this paper we report that the MRI microcoil can provide hundreds, and even thousands of voxels in the same volume.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19163097      PMCID: PMC3196548          DOI: 10.1109/IEMBS.2008.4649594

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  17 in total

1.  MR imaging of implanted depth and subdural electrodes: is it safe?

Authors:  L M Davis; D D Spencer; S S Spencer; R A Bronen
Journal:  Epilepsy Res       Date:  1999-06       Impact factor: 3.045

2.  3D micron-scale MRI of single biological cells.

Authors:  L Ciobanu; C H Pennington
Journal:  Solid State Nucl Magn Reson       Date:  2004-01       Impact factor: 2.293

3.  Ultra high-resolution fMRI in monkeys with implanted RF coils.

Authors:  Nikos Logothetis; Hellmut Merkle; Mark Augath; Torsten Trinath; Kâmil Ugurbil
Journal:  Neuron       Date:  2002-07-18       Impact factor: 17.173

4.  Interventional magnetic resonance angiography with no strings attached: wireless active catheter visualization.

Authors:  Harald H Quick; Michael O Zenge; Hilmar Kuehl; Gernot Kaiser; Stephanie Aker; Sandra Massing; Silke Bosk; Mark E Ladd
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

5.  Magnetic resonance microscopy of spinal cord injury in mouse using a miniaturized implantable RF coil.

Authors:  Mehmet Bilgen
Journal:  J Neurosci Methods       Date:  2006-08-04       Impact factor: 2.390

6.  Investigation of NMR limits of detection for implantable microcoils.

Authors:  N Baxan; A Rengle; G Pasquet; J-F Châteaux; A Briguet; P Morin; L Fakri-Bouchet
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2007

7.  Intravascular magnetic resonance imaging using a loopless catheter antenna.

Authors:  O Ocali; E Atalar
Journal:  Magn Reson Med       Date:  1997-01       Impact factor: 4.668

8.  Implanted coil MR microscopy of renal pathology.

Authors:  T H Farmer; G A Johnson; G P Cofer; R R Maronpot; D Dixon; L W Hedlund
Journal:  Magn Reson Med       Date:  1989-06       Impact factor: 4.668

9.  Magnetic resonance microscopy of chick embryos in ovo.

Authors:  E L Effmann; G A Johnson; B R Smith; G A Talbott; G Cofer
Journal:  Teratology       Date:  1988-07

10.  In vivo 31P nuclear magnetic resonance measurements in canine heart using a catheter-coil.

Authors:  H L Kantor; R W Briggs; R S Balaban
Journal:  Circ Res       Date:  1984-08       Impact factor: 17.367

View more
  2 in total

Review 1.  How and when the fMRI BOLD signal relates to underlying neural activity: the danger in dissociation.

Authors:  Arne Ekstrom
Journal:  Brain Res Rev       Date:  2009-12-21

2.  Electricity and Magnetism: Insights into the brain from multimodal imaging.

Authors:  M S Cohen
Journal:  IEEE Netw       Date:  2009-11       Impact factor: 10.693

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.