Abstract

Inductively coupled implanted coils have been shown to provide up to a 10-fold increase in signal-to-noise ratio when compared to whole-body imaging of small animals. The current study was designed to extend the implanted coil imaging technique to a rodent model of renal pathology. Resonant radiofrequency (RF) coils were implanted around the left kidney of four rats and inductively coupled from within a birdcage body coil. All images were acquired at 2 T using a T1-weighted spin-echo sequence with TR = 500 ms and TE = 20 ms. In vivo MR microscopy with voxels of 117 x 117 x 2000 microns demonstrated cortex, inner and outer medulla, and major vascular structures on baseline images. Mercuric chloride-induced nephrotoxic acute tubular necrosis (ATN) diminished cortico-medullary contrast at 24 h after dosing with pathologic evaluation demonstrating nephrotoxic changes in the inner cortex. The kidney regained a baseline MR appearance 360 h after dosing and resolution of the damage was confirmed with histology. T1 data were gathered on excised kidneys as an adjunct to the images to help correlate the loss and return of cortico-medullary contrast with the pathology and pathophysiology of nephrotoxic ATN. With implanted RF coils we were able to demonstrate renal pathology and follow its subsequent resolution. Specifically, loss and return of cortico-medullary contrast as a result of nephrotoxic ATN were serially documented in four rats. Such serial in vivo studies performed on single animals should further the use of MR microscopy by minimizing the number of animals required for adequate biostatistics.

Entities:  

Mesh:

Year:  1989        PMID: 2733588     DOI: 10.1002/mrm.1910100304

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Towards a microcoil for intracranial and intraductal MR microscopy.

Authors:  Debra S Strick; Ray L Nunnally; Jolinda C Smith; W Clark; Dixie J Mills; Mark S Cohen; Jack W Judy
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

2.  Four-dimensional MRI of renal function in the developing mouse.

Authors:  Luke Xie; Ergys Subashi; Yi Qi; Mark A Knepper; G Allan Johnson
Journal:  NMR Biomed       Date:  2014-07-26       Impact factor: 4.044

3.  Magnetic resonance histology of age-related nephropathy in the Sprague Dawley rat.

Authors:  Luke Xie; Rachel E Cianciolo; Brian Hulette; Ha Won Lee; Yi Qi; Gary Cofer; G Allan Johnson
Journal:  Toxicol Pathol       Date:  2012-04-13       Impact factor: 1.902

4.  High-resolution MRI of kidney microstructures at 7.05 T with an endo-colonic Wireless Amplified NMR detector.

Authors:  Xianchun Zeng; Shuangtao Ma; John M Kruger; Rongpin Wang; Xiaobo Tan; Chunqi Qian
Journal:  J Magn Reson       Date:  2019-04-25       Impact factor: 2.229

Review 5.  Engineering novel detectors and sensors for MRI.

Authors:  Chunqi Qian; Gary Zabow; Alan Koretsky
Journal:  J Magn Reson       Date:  2012-11-29       Impact factor: 2.229

6.  Longitudinal assessment of mouse renal injury using high-resolution anatomic and magnetization transfer MR imaging.

Authors:  Feng Wang; Rosie Jiang; Keiko Takahashi; John Gore; Raymond C Harris; Takamune Takahashi; C Chad Quarles
Journal:  Magn Reson Imaging       Date:  2014-08-02       Impact factor: 2.546

7.  Wireless Reconfigurable RF Detector Array for Focal and Multiregional Signal Enhancement.

Authors:  Wei Qian; Xin Yu; Chunqi Qian
Journal:  IEEE Access       Date:  2020-07-24       Impact factor: 3.367

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.