Literature DB >> 19162710

Film-type transducer materials PVDF and EMFi in the measurement of heart and respiration rates.

Satu Kärki1, Jukka Lekkala.   

Abstract

Film-type transducer materials polyvinylidenefluoride (PVDF) and ElectroMechanical Film (EMFi) were used in the measurement of heart and respiration rates on the chest wall at rest. The aim here was to evaluate if the both materials are capable to measure the heart and respiration rates correctly and also to found out if there are differences between the results of PVDF and EMFi. The movements provided by the pulsation of heart and respiration were converted into an electrical signal by the sensors. The signals were amplified and transmitted to a computer. The data was analyzed with Matlab software. The signals were filtered to reveal the heart pulsation and respiration components. Power spectral density (PSD) spectrum was computed to determine the heart and respiration rates. ECG was used as a reference signal for the heart rate and a thermistor for the respiration rate. Both transducer materials provided good results and no differences between PVDF and EMFi were found. The heart rates measured with PVDF and EMFi sensors corresponded to the values calculated from the ECG signal. Also the respiration rates correlated with the values determined with the thermistor. To conclude, both materials provided reliable results in the measurements of heart and respiration rates.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19162710     DOI: 10.1109/IEMBS.2008.4649207

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Increased respiratory effort during sleep is non-invasively detected with movement sensor.

Authors:  Mirja Tenhunen; Esa Rauhala; Jussi Virkkala; Olli Polo; Antti Saastamoinen; Sari-Leena Himanen
Journal:  Sleep Breath       Date:  2010-10-20       Impact factor: 2.816

2.  Polyvinylidene fluoride film based nasal sensor to monitor human respiration pattern: an initial clinical study.

Authors:  G Roopa Manjunatha; K Rajanna; D Roy Mahapatra; M M Nayak; Uma Maheswari Krishnaswamy; R Srinivasa
Journal:  J Clin Monit Comput       Date:  2013-06-16       Impact factor: 2.502

Review 3.  Detecting vital signs with wearable wireless sensors.

Authors:  Tuba Yilmaz; Robert Foster; Yang Hao
Journal:  Sensors (Basel)       Date:  2010-12-02       Impact factor: 3.576

4.  Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study.

Authors:  Maartje M S Hendriks; Jaap H van Lotringen; Marije Vos-van der Hulst; Noël L W Keijsers
Journal:  JMIR Mhealth Uhealth       Date:  2021-02-08       Impact factor: 4.773

5.  The Structure Design of Piezoelectric Poly(vinylidene Fluoride) (PVDF) Polymer-Based Sensor Patch for the Respiration Monitoring under Dynamic Walking Conditions.

Authors:  Kin-Fong Lei; Yi-Zheng Hsieh; Yi-Yuan Chiu; Min-Hsien Wu
Journal:  Sensors (Basel)       Date:  2015-07-31       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.