Literature DB >> 19154077

Correlation between angiographic and particle image velocimetry quantifications of flow diverters in an in vitro model of elastase-induced rabbit aneurysms.

Asher L Trager1, Chander Sadasivan, Jaehoon Seong, Baruch B Lieber.   

Abstract

The rupture of a cerebral aneurysm can result in a hemorrhagic stroke. A flow diverter, which is a porous tubular mesh, can be placed across the neck of a cerebral aneurysm to induce the cessation of flow and initiate the formation of an intra-aneurysmal thrombus. By finding a correlation between particle image velocimetry (PIV) and digital subtraction angiography, a better assessment of how well an aneurysm is excluded from the parent artery can be made in the clinical setting. A model of a rabbit elastase-induced aneurysm was connected to a mock circulation loop. The model was then placed under angiography. Recorded angiograms were analyzed so that a contrast concentration-time curve based on the average grayscale intensity inside the aneurysm could be determined. That curve was then fitted to a mathematical model that quantifies the influence of convection and diffusion on contrast transport. Optimized parameters were correlated with the intraneurysmal mean kinetic energy measured by PIV in the same aneurysm model. A strong correlation was observed between the convection and diffusion time constants and the mean kinetic energy inside the aneurysm. Analyzing the flow of angiographic contrast into and out of the aneurysm after implantation of a flow diverter allows for prediction of the efficacy of the device in excluding the aneurysm. Correlating hydrodynamic measures obtained by angiography to those obtained by detailed techniques such as PIV increases confidence in such predictions.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19154077      PMCID: PMC2679683          DOI: 10.1115/1.3049528

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  9 in total

1.  Morphology of elastase-induced cerebral aneurysm model in rabbit and rapid prototyping of elastomeric transparent replicas.

Authors:  Jaehoon Seong; Chander Sadasivan; Masanari Onizuka; Matthew J Gounis; Fletcher Christian; Laszlo Miskolczi; Ajay K Wakhloo; Baruch B Lieber
Journal:  Biorheology       Date:  2005       Impact factor: 1.875

2.  Stents for intracranial aneurysms: the beginning of a new endovascular era?

Authors:  A K Wakhloo; G Lanzino; B B Lieber; L N Hopkins
Journal:  Neurosurgery       Date:  1998-08       Impact factor: 4.654

3.  Endovascular creation of an in vivo bifurcation aneurysm model in rabbits.

Authors:  H J Cloft; T A Altes; W F Marx; R J Raible; S B Hudson; G A Helm; J W Mandell; M E Jensen; J E Dion; D F Kallmes
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

Review 4.  Functional angiography.

Authors:  Baruch B Lieber; Chander Sadasivan; Matthew J Gounis; Jaehoon Seong; Laszlo Miskolczi; Ajay K Wakhloo
Journal:  Crit Rev Biomed Eng       Date:  2005

5.  Stent placement for arterial and venous cerebrovascular disease: preliminary experience.

Authors:  M P Marks; M D Dake; G K Steinberg; A M Norbash; B Lane
Journal:  Radiology       Date:  1994-05       Impact factor: 11.105

6.  Saccular aneurysm induction by elastase digestion of the arterial wall: a new animal model.

Authors:  L Miskolczi; L R Guterman; J D Flaherty; L N Hopkins
Journal:  Neurosurgery       Date:  1998-09       Impact factor: 4.654

7.  Angiographic quantification of contrast medium washout from cerebral aneurysms after stent placement.

Authors:  Chander Sadasivan; Baruch B Lieber; Matthew J Gounis; Demetrius K Lopes; L N Hopkins
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

8.  Histologic and morphologic comparison of experimental aneurysms with human intracranial aneurysms.

Authors:  T Abruzzo; G G Shengelaia; R C Dawson; D S Owens; C M Cawley; M B Gravanis
Journal:  AJNR Am J Neuroradiol       Date:  1998-08       Impact factor: 3.825

9.  In vitro evaluation of flow divertors in an elastase-induced saccular aneurysm model in rabbit.

Authors:  Jaehoon Seong; Ajay K Wakhloo; Baruch B Lieber
Journal:  J Biomech Eng       Date:  2007-12       Impact factor: 2.097

  9 in total
  17 in total

Review 1.  Endoluminal scaffolds for vascular reconstruction and exclusion of aneurysms from the cerebral circulation.

Authors:  Baruch B Lieber; Chander Sadasivan
Journal:  Stroke       Date:  2010-10       Impact factor: 7.914

2.  Flow-diverter stenting of post-traumatic bilateral anterior cerebral artery pseudoaneurysm: A case report.

Authors:  Andrea Giorgianni; Carlo Pellegrino; Renzo Minotto; Anna Mercuri; Lara Frattini; Fabio Baruzzi; Luca Valvassori
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

3.  The 'Sphere': A Dedicated Bifurcation Aneurysm Flow-Diverter Device.

Authors:  Thomas Peach; J Frederick Cornhill; Anh Nguyen; Howard Riina; Yiannis Ventikos
Journal:  Cardiovasc Eng Technol       Date:  2014-08-26       Impact factor: 2.495

4.  Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results.

Authors:  I Saatci; K Yavuz; C Ozer; S Geyik; H S Cekirge
Journal:  AJNR Am J Neuroradiol       Date:  2012-07-19       Impact factor: 3.825

5.  In vitro angiographic comparison of the flow-diversion performance of five neurovascular stents.

Authors:  Ronak J Dholakia; Ari D Kappel; Andrew Pagano; Henry H Woo; Baruch B Lieber; David J Fiorella; Chander Sadasivan
Journal:  Interv Neuroradiol       Date:  2017-12-14       Impact factor: 1.610

6.  Patency of the anterior choroidal artery after flow-diversion treatment of internal carotid artery aneurysms.

Authors:  W Brinjikji; D F Kallmes; H J Cloft; G Lanzino
Journal:  AJNR Am J Neuroradiol       Date:  2014-10-22       Impact factor: 3.825

7.  Comparison of the in vitro hemodynamic performance of new flow diverters for bypass of brain aneurysms.

Authors:  Asher L Trager; Chander Sadasivan; Baruch B Lieber
Journal:  J Biomech Eng       Date:  2012-08       Impact factor: 2.097

8.  The effect of stents on intra-aneurysmal hemodynamics: in vitro evaluation of a pulsatile sidewall aneurysm using laser Doppler anemometry.

Authors:  Franziska Dorn; Franz Niedermeyer; Andrea Balasso; Dieter Liepsch; Thomas Liebig
Journal:  Neuroradiology       Date:  2010-06-19       Impact factor: 2.804

9.  Flow Diversion for Ophthalmic Artery Aneurysms.

Authors:  A M Burrows; W Brinjikji; R C Puffer; H Cloft; D F Kallmes; G Lanzino
Journal:  AJNR Am J Neuroradiol       Date:  2016-06-02       Impact factor: 3.825

10.  Early angiographic changes of intra-aneurysmal flow after flow-diverter stent treatment are not predictive of therapeutic success.

Authors:  Paul-Emile Labeyrie; Benjamin Gory; Udi Sadeh-Gonike; Nazyed Huguet; Rotem Sivan-Hoffmann; Roberto Riva; Patrick Courthéoux; Francis Turjman
Journal:  Interv Neuroradiol       Date:  2016-08-10       Impact factor: 1.610

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.