Literature DB >> 22938365

Comparison of the in vitro hemodynamic performance of new flow diverters for bypass of brain aneurysms.

Asher L Trager1, Chander Sadasivan, Baruch B Lieber.   

Abstract

One possible treatment for cerebral aneurysms is a porous tubular structure, similar to a stent, called a flow diverter. A flow diverter can be placed across the neck of a cerebral aneurysm to induce the cessation of flow and initiate the formation of an intra-aneurysmal thrombus. This excludes the aneurysm from the parent artery and returns the flow of blood to normal. Previous flow diverting devices have been analyzed to determine optimal characteristics, such as braiding angle and wire diameter. From this information, a new optimized device was designed to achieve equivalent hemodynamic performance to the previous best device, but with better longitudinal flexibility to preserve physiological arterial configuration. The new device was tested in vitro in an elastomeric replica of the rabbit elastase induced aneurysm model and is now in the process of being tested in vivo. Particle image velocimetry was utilized to determine the velocity field in the plane of symmetry of the model under pulsatile flow conditions. Device hemodynamic performance indices such as the hydrodynamic circulation were evaluated from the velocity fields. Comparison of these indices with the previous best device and a control shows that the significant design changes of the device did not change its hemodynamic attributes (p > 0.05).

Entities:  

Mesh:

Year:  2012        PMID: 22938365      PMCID: PMC3432972          DOI: 10.1115/1.4006454

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  18 in total

1.  The surgical anatomy of the perforating branches of the anterior choroidal artery.

Authors:  S Marinković; H Gibo; L Brigante; I Nikodijević; P Petrović
Journal:  Surg Neurol       Date:  1999-07

2.  Morphology of elastase-induced cerebral aneurysm model in rabbit and rapid prototyping of elastomeric transparent replicas.

Authors:  Jaehoon Seong; Chander Sadasivan; Masanari Onizuka; Matthew J Gounis; Fletcher Christian; Laszlo Miskolczi; Ajay K Wakhloo; Baruch B Lieber
Journal:  Biorheology       Date:  2005       Impact factor: 1.875

3.  Stents for intracranial aneurysms: the beginning of a new endovascular era?

Authors:  A K Wakhloo; G Lanzino; B B Lieber; L N Hopkins
Journal:  Neurosurgery       Date:  1998-08       Impact factor: 4.654

4.  The surgical anatomy of the perforating branches of the basilar artery.

Authors:  S V Marinković; H Gibo
Journal:  Neurosurgery       Date:  1993-07       Impact factor: 4.654

5.  Stent placement for arterial and venous cerebrovascular disease: preliminary experience.

Authors:  M P Marks; M D Dake; G K Steinberg; A M Norbash; B Lane
Journal:  Radiology       Date:  1994-05       Impact factor: 11.105

6.  Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow.

Authors:  Baruch B Lieber; Veronica Livescu; L N Hopkins; Ajay K Wakhloo
Journal:  Ann Biomed Eng       Date:  2002-06       Impact factor: 3.934

7.  Treatment of experimental carotid aneurysms by endoprosthesis implantation: preliminary report.

Authors:  F Turjman; G Acevedo; T Moll; J Duquesnel; R Eloy; M Sindou
Journal:  Neurol Res       Date:  1993-06       Impact factor: 2.448

8.  Self-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model.

Authors:  A K Wakhloo; F Schellhammer; J de Vries; J Haberstroh; M Schumacher
Journal:  AJNR Am J Neuroradiol       Date:  1994-03       Impact factor: 3.825

9.  Embolization of experimentally created aneurysms with intravascular stent devices.

Authors:  G Geremia; M Haklin; L Brennecke
Journal:  AJNR Am J Neuroradiol       Date:  1994-08       Impact factor: 3.825

10.  In vitro evaluation of flow divertors in an elastase-induced saccular aneurysm model in rabbit.

Authors:  Jaehoon Seong; Ajay K Wakhloo; Baruch B Lieber
Journal:  J Biomech Eng       Date:  2007-12       Impact factor: 2.097

View more
  4 in total

1.  In vitro angiographic comparison of the flow-diversion performance of five neurovascular stents.

Authors:  Ronak J Dholakia; Ari D Kappel; Andrew Pagano; Henry H Woo; Baruch B Lieber; David J Fiorella; Chander Sadasivan
Journal:  Interv Neuroradiol       Date:  2017-12-14       Impact factor: 1.610

2.  Relationship between aneurysm occlusion and flow diverting device oversizing in a rabbit model.

Authors:  Simona Hodis; Yong-Hong Ding; Daying Dai; Ravi Lingineni; Fernando Mut; Juan Cebral; David Kallmes; Ramanathan Kadirvel
Journal:  J Neurointerv Surg       Date:  2014-11-11       Impact factor: 5.836

3.  Particle imaging velocimetry evaluation of intracranial stents in sidewall aneurysm: hemodynamic transition related to the stent design.

Authors:  Pierre Bouillot; Olivier Brina; Rafik Ouared; Karl-Olof Lovblad; Mohamed Farhat; Vitor Mendes Pereira
Journal:  PLoS One       Date:  2014-12-03       Impact factor: 3.240

Review 4.  The Effect of Stents in Cerebral Aneurysms: A Review.

Authors:  Kenan Alkhalili; Jack Hannallah; Mary Cobb; Nohra Chalouhi; Jessica L Philips; Angela B Echeverria; Pascal Jabbour; M Haithem Babiker; David H Frakes; L Fernando Gonzalez
Journal:  Asian J Neurosurg       Date:  2018 Apr-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.