Literature DB >> 19154065

Spatially resolved streaming potentials of human intervertebral disk motion segments under dynamic axial compression.

James C Iatridis1, Masaru Furukawa, Ian A F Stokes, Mack G Gardner-Morse, Jeffrey P Laible.   

Abstract

Intervertebral disk degeneration results in alterations in the mechanical, chemical, and electrical properties of the disk tissue. The purpose of this study is to record spatially resolved streaming potential measurements across intervertebral disks exposed to cyclic compressive loading. We hypothesize that the streaming potential profile across the disk will vary with radial position and frequency and is proportional to applied load amplitude, according to the presumed fluid-solid relative velocity and measured glycosaminoglycan content. Needle electrodes were fabricated using a linear array of AgAgCl micro-electrodes and inserted into human motion segments in the midline from anterior to posterior. They were connected to an amplifier to measure electrode potentials relative to the saline bath ground. Motion segments were loaded in axial compression under a preload of 500 N, sinusoidal amplitudes of +/-200 N and +/-400 N, and frequencies of 0.01 Hz, 0.1 Hz, and 1 Hz. Streaming potential data were normalized by applied force amplitude, and also compared with paired experimental measurements of glycosaminoglycans in each disk. Normalized streaming potentials varied significantly with sagittal position and there was a significant location difference at the different frequencies. Normalized streaming potential was largest in the central nucleus region at frequencies of 0.1 Hz and 1.0 Hz with values of approximately 3.5 microVN. Under 0.01 Hz loading, normalized streaming potential was largest in the outer annulus regions with a maximum value of 3.0 microVN. Correlations between streaming potential and glycosaminoglycan content were significant, with R(2) ranging from 0.5 to 0.8. Phasic relationships between applied force and electrical potential did not differ significantly by disk region or frequency, although the largest phase angles were observed at the outermost electrodes. Normalized streaming potentials were associated with glycosaminoglycan content, fluid, and ion transport. Results suggested that at higher frequencies the transport of water and ions in the central nucleus region may be larger, while at lower frequencies there is enhanced transport near the periphery of the annulus. This study provides data that will be helpful to validate multiphasic models of the disk.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19154065      PMCID: PMC2757255          DOI: 10.1115/1.3005164

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  25 in total

Review 1.  Imaging intervertebral disc degeneration.

Authors:  Victor Haughton
Journal:  J Bone Joint Surg Am       Date:  2006-04       Impact factor: 5.284

2.  Preliminary evaluation of a scheme for grading the gross morphology of the human intervertebral disc.

Authors:  J P Thompson; R H Pearce; M T Schechter; M E Adams; I K Tsang; P B Bishop
Journal:  Spine (Phila Pa 1976)       Date:  1990-05       Impact factor: 3.468

Review 3.  What is intervertebral disc degeneration, and what causes it?

Authors:  Michael A Adams; Peter J Roughley
Journal:  Spine (Phila Pa 1976)       Date:  2006-08-15       Impact factor: 3.468

4.  In vitro organ culture of the bovine intervertebral disc: effects of vertebral endplate and potential for mechanobiology studies.

Authors:  Cynthia R Lee; James C Iatridis; Lucy Poveda; Mauro Alini
Journal:  Spine (Phila Pa 1976)       Date:  2006-03-01       Impact factor: 3.468

Review 5.  Mechanobiology of the intervertebral disc and relevance to disc degeneration.

Authors:  Lori A Setton; Jun Chen
Journal:  J Bone Joint Surg Am       Date:  2006-04       Impact factor: 5.284

6.  Streaming potentials during the confined compression creep test of normal and proteoglycan-depleted cartilage.

Authors:  A C Chen; T T Nguyen; R L Sah
Journal:  Ann Biomed Eng       Date:  1997 Mar-Apr       Impact factor: 3.934

7.  The role of cartilage streaming potential, fluid flow and pressure in the stimulation of chondrocyte biosynthesis during dynamic compression.

Authors:  Y J Kim; L J Bonassar; A J Grodzinsky
Journal:  J Biomech       Date:  1995-09       Impact factor: 2.712

8.  The value of T2 relaxation times to characterize lumbar intervertebral disks: preliminary results.

Authors:  J Perry; V Haughton; P A Anderson; Y Wu; J Fine; C Mistretta
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

9.  Transport of fluid and ions through a porous-permeable charged-hydrated tissue, and streaming potential data on normal bovine articular cartilage.

Authors:  W Y Gu; W M Lai; V C Mow
Journal:  J Biomech       Date:  1993-06       Impact factor: 2.712

10.  Tetrapolar measurement of electrical conductivity and thickness of articular cartilage.

Authors:  J S Binette; M Garon; P Savard; M D McKee; M D Buschmann
Journal:  J Biomech Eng       Date:  2004-08       Impact factor: 2.097

View more
  3 in total

1.  An Anisotropic Multiphysics Model for Intervertebral Disk.

Authors:  Xin Gao; Qiaoqiao Zhu; Weiyong Gu
Journal:  J Appl Mech       Date:  2015-11-09       Impact factor: 2.168

2.  Delivering mesenchymal stem cells in collagen microsphere carriers to rabbit degenerative disc: reduced risk of osteophyte formation.

Authors:  Yuk Yin Li; Hua Jia Diao; Tze Kit Chik; Cin Ting Chow; Xiao Meng An; Victor Leung; Kenneth Man Chi Cheung; Barbara Pui Chan
Journal:  Tissue Eng Part A       Date:  2014-02-06       Impact factor: 3.845

3.  A Structurally and Functionally Biomimetic Biphasic Scaffold for Intervertebral Disc Tissue Engineering.

Authors:  Andrew Tsz Hang Choy; Barbara Pui Chan
Journal:  PLoS One       Date:  2015-06-26       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.