Literature DB >> 19147306

Dosimetric impact and theoretical clinical benefits of fiducial markers for dose escalated prostate cancer radiation treatment.

Isabelle Gauthier1, Jean-François Carrier, Dominic Béliveau-Nadeau, Bernard Fortin, Daniel Taussky.   

Abstract

PURPOSE: To assess the impact of fiducial markers and daily kilovoltage imaging (FM-kV) on dose-volume histogram (DVH) parameters and normal tissue complication probabilities (NTCPs) for the rectum and bladder during prostate cancer radiotherapy. METHODS AND MATERIALS: Two different setup scenarios were compared for 20 patients treated with three-dimensional conformal radiotherapy (3D-CRT) for localized prostate cancer to a total dose of 76 Gy: a traditional setup with planning target volume (PTV) margins associated with skin mark alignment vs. another setup using FM-kV. Various DVH parameters were compared, including Radiation Therapy Oncology Group (RTOG) dose-volume constraints for the rectum and bladder. Analysis of NTCPs was also performed according to the Lyman model.
RESULTS: With the traditional setup, 85% of patients had rectal V70(Gy) >25% compared with 45% with FM-kV. Moreover, 30% of patients with traditional setup vs. 5% with FM-kV did not fulfill at least 3 RTOG constraint parameters for the rectum. Mean rectal and bladder dose were 4.7 Gy and 6.7 Gy less, respectively, with FM-kV. The NTCP for the rectum was 11.5% with the traditional setup and 9% with FM-kV. This indicates that with FM-kV, the prescription dose could be increased by 2.1 Gy while keeping the same level of late rectal toxicity as with the traditional setup.
CONCLUSIONS: Use of FM-kV is an efficient way of lowering the proportion of patients not fulfilling RTOG rectal and bladder dose-volume constraints. The results of the NTCP analysis suggest that the PTV margin reduction allowed by FM-kV should decrease the rate of late rectal toxicities or may allow moderate dose escalation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19147306     DOI: 10.1016/j.ijrobp.2008.09.043

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  8 in total

1.  Qualitative evaluation of fiducial markers for radiotherapy imaging.

Authors:  Maria F Chan; Gil'ad N Cohen; Joseph O Deasy
Journal:  Technol Cancer Res Treat       Date:  2014-09-16

2.  Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--experiments, simulation, and dosimetry study.

Authors:  Wu Liu; Jianguo Qian; Steven L Hancock; Lei Xing; Gary Luxton
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Reduction in patient-reported acute morbidity in prostate cancer patients treated with 81-Gy Intensity-modulated radiotherapy using reduced planning target volume margins and electromagnetic tracking: assessing the impact of margin reduction study.

Authors:  Howard M Sandler; Ping-Yu Liu; Rodney L Dunn; David C Khan; Scott E Tropper; Martin G Sanda; Constantine A Mantz
Journal:  Urology       Date:  2010-02-13       Impact factor: 2.649

4.  A predictive model to guide management of the overlap region between target volume and organs at risk in prostate cancer volumetric modulated arc therapy.

Authors:  Malcolm D Mattes; Jennifer C Lee; Sara Elnaiem; Adel Guirguis; N C Ikoro; Hani Ashamalla
Journal:  Radiat Oncol J       Date:  2014-03-27

Review 5.  Target margins in radiotherapy of prostate cancer.

Authors:  Slav Yartsev; Glenn Bauman
Journal:  Br J Radiol       Date:  2016-07-20       Impact factor: 3.039

6.  A Dosimetric Comparison between Conventional Fractionated and Hypofractionated Image-guided Radiation Therapies for Localized Prostate Cancer.

Authors:  Ming Li; Gao-Feng Li; Xiu-Yu Hou; Hong Gao; Yong-Gang Xu; Ting Zhao
Journal:  Chin Med J (Engl)       Date:  2016-06-20       Impact factor: 2.628

7.  Clinical and radiobiological evaluation of a method for planning target volume generation dependent on organ-at-risk exclusions in magnetic resonance imaging-based prostate radiotherapy.

Authors:  Brian Ruiz; Yuanming Feng
Journal:  Phys Imaging Radiat Oncol       Date:  2018-12-07

8.  Determination of optimal fiducial marker across image-guided radiation therapy (IGRT) modalities: visibility and artifact analysis of gold, carbon, and polymer fiducial markers.

Authors:  Lydia L Handsfield; Ning J Yue; Jinghao Zhou; Ting Chen; Sharad Goyal
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  8 in total