Literature DB >> 19147025

Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure.

George X Ding1, Charles W Coffey.   

Abstract

PURPOSE: Image-guided radiation therapy has emerged as the new paradigm in radiotherapy. This work is to provide detailed information concerning the additional imaging doses to patients' radiosensitive organs from a kilovoltage cone beam computed tomography (kV CBCT) scan procedure. METHODS AND MATERIALS: The Vanderbilt-Monte-Carlo-Beam-Calibration (VMCBC; Vanderbilt University, Nashville, TN) algorithm was used to calculate radiation dose to organs resulting from a kV CBCT imaging guidance procedure. Eight patients, including 3 pediatric and 5 adult patients, were investigated. The CBCT scans in both full- and half-fan modes were studied.
RESULTS: For a head-and-neck scan in half-fan mode, dose-volume histogram analyses show mean doses of 7 and 8 cGy to the eyes, 5 and 6 cGy to the spinal cord, 5 and 6 cGy to the brain, and 18 and 23 cGy to the cervical vertebrae for an adult and a 29-month-old child, respectively. The dose from a scan in full-fan mode is 10-20% lower than that in half-fan mode. For an abdominal scan, mean doses are 3 and 7 cGy to prostate and 7 and 17 cGy to femoral heads for a large adult patient and a 31-month-old pediatric patient, respectively.
CONCLUSIONS: Doses to radiosensitive organs can total 300 cGy accrued over an entire treatment course if kV CBCT scans are acquired daily. These findings provide needed data for clinicians to make informed decisions concerning additional imaging doses. The dose to bone is two to four times greater than dose to soft tissue for kV x-rays, which should be considered, especially for pediatric patients.

Entities:  

Mesh:

Year:  2009        PMID: 19147025     DOI: 10.1016/j.ijrobp.2008.10.006

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  35 in total

1.  Risk factors related to interfractional variation in whole pelvic irradiation for locally advanced pelvic malignancies.

Authors:  W S Yoon; D S Yang; J A Lee; S Lee; Y J Park; C Y Kim
Journal:  Strahlenther Onkol       Date:  2012-02-10       Impact factor: 3.621

2.  Dosimetric properties and commissioning of cone-beam CT image beam line with a carbon target.

Authors:  Y Dzierma; F G Nuesken; N P Licht; C Ruebe
Journal:  Strahlenther Onkol       Date:  2013-05-30       Impact factor: 3.621

3.  Monte Carlo calculation of imaging doses from diagnostic multidetector CT and kilovoltage cone-beam CT as part of prostate cancer treatment plans.

Authors:  Aiping Ding; Jianwei Gu; Alexei V Trofimov; X George Xu
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

4.  Reconstructing cone-beam CT with spatially varying qualities for adaptive radiotherapy: a proof-of-principle study.

Authors:  Wenting Lu; Hao Yan; Xuejun Gu; Zhen Tian; Ouyang Luo; Liu Yang; Linghong Zhou; Laura Cervino; Jing Wang; Steve Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2014-09-26       Impact factor: 3.609

Review 5.  Current status of IMRT in head and neck cancer.

Authors:  Jaime Gomez-Millan; Jesús Romero Fernández; Jose Antonio Medina Carmona
Journal:  Rep Pract Oncol Radiother       Date:  2013-10-20

6.  [Organizational models of inpatient emergency and acute care].

Authors:  A Kaltwasser; C Dodt
Journal:  Med Klin Intensivmed Notfmed       Date:  2014-10       Impact factor: 0.840

7.  Dosimetry challenges for implementing emerging technologies.

Authors:  Fang-Fang Yin; Mark Oldham; Jing Cai; Qiuwen Wu
Journal:  J Phys Conf Ser       Date:  2010

8.  Effects of remedies made in patient setup process on residual setup errors and margins in head and neck cancer radiotherapy based on 2D image guidance.

Authors:  Mika Kapanen; Marko Laaksomaa; Tapio Tulijoki; Pirkko-Liisa Kellokumpu-Lehtinen; Simo Hyödynmaa
Journal:  Rep Pract Oncol Radiother       Date:  2015-04-01

9.  A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer.

Authors:  J P Santoro; J McNamara; E Yorke; H Pham; A Rimner; K E Rosenzweig; G S Mageras
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

10.  Technical note: improved positioning protocol for patient setup accuracy in conventional radiotherapy for lung cancer.

Authors:  Hongbo Chai; Yuichiro Narita; Masafumi Takagi; Mikiko Kudo; Tomomi Kimura; Keiichi Kattou
Journal:  Radiol Phys Technol       Date:  2019-09-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.