Literature DB >> 19138636

Measurements of mandibular canal region obtained by cone-beam computed tomography: a cadaveric study.

Kivanç Kamburoğlu1, Cenk Kiliç, Tuncer Ozen, Selcen Pehlivan Yüksel.   

Abstract

OBJECTIVE: The objective of this study was to assess the accuracy and reproducibility of cone-beam CT measurements of specific distances around the mandibular canal by comparing them to direct digital caliper measurements.
METHODS: Six formalin-fixed hemimandible specimens were examined using the ILUMA cone-beam CT system. Images were obtained at 120 kVp, 3.8 mA, and a voxel size of 0.2 mm, with an exposure time of 40 seconds. Specimens were cut into sections at 7 locations using a Lindemann burr, and a digital caliper was used to measure the following distances on both the anterior and posterior sides of each section: Mandibular Width (W); Mandibular Length (L); Upper Distance (UD); Lower Distance (LD); Buccal Distance (BD); and Lingual Distance (LID). The same distances were measured on the corresponding cross-sectional cone-beam CT images using the built-in measurement software. All caliper and cone-beam CT measurements were made by 2 independent trained observers and were repeated after an interval of 1 week. The Bland/Altman method was used to calculate intra- and inter-rater reliability. Intra-class correlation coefficients (ICCs) from 2-way random effects model were calculated. Agreements between cone-beam CT and direct digital caliper were calculated by ICC for 6 distances and 2 observers.
RESULTS: Intraobserver and interobserver measurements for all distances showed high agreement. ICCs for intraobserver agreement ranged from 0.86 to 0.97 for cone-beam CT measurements and from 0.98 to 0.99 for digital caliper measurements. ICCs between observers ranged from 0.84 to 0.97 for the cone-beam CT measurements and from 0.78 to 0.97 for the digital caliper measurements. ICCs for cone-beam CT and direct digital caliper ranged from 0.61 to 0.93 for the first observer and from 0.40 to 0.95 for the second observer.
CONCLUSION: Accuracy of cone-beam CT measurements of various distances surrounding the mandibular canal was comparable to that of digital caliper measurements.

Entities:  

Mesh:

Year:  2009        PMID: 19138636     DOI: 10.1016/j.tripleo.2008.10.012

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  28 in total

1.  A comparative study of the accuracy and reliability of multidetector CT and cone beam CT in the assessment of dental implant site dimensions.

Authors:  K Kamburoglu; S Yüksel
Journal:  Dentomaxillofac Radiol       Date:  2011-10       Impact factor: 2.419

2.  A retrospective comparison of the location and diameter of the inferior alveolar canal at the mental foramen and length of the anterior loop between American and Taiwanese cohorts using CBCT.

Authors:  Judy Chia-Hui Chen; Li-Min Lin; James R Geist; Jing-Yi Chen; Chung-Ho Chen; Yuk-Kwan Chen
Journal:  Surg Radiol Anat       Date:  2012-06-05       Impact factor: 1.246

3.  Evaluation of bifid mandibular canals with cone-beam computed tomography in a Turkish adult population: a retrospective study.

Authors:  Kaan Orhan; Seçil Aksoy; Burak Bilecenoglu; Bayram Ufuk Sakul; Candan Semra Paksoy
Journal:  Surg Radiol Anat       Date:  2010-12-16       Impact factor: 1.246

4.  Comparative evaluation of mandibular canal visibility on cross-sectional cone-beam CT images: a retrospective study.

Authors:  Mahogany S Miles; Edwin T Parks; George J Eckert; Steven B Blanchard
Journal:  Dentomaxillofac Radiol       Date:  2015-11-06       Impact factor: 2.419

5.  Accuracy of software designed for automated localization of the inferior alveolar nerve canal on cone beam CT images.

Authors:  Ehsan Bahrampour; Ali Zamani; Sadegh Kashkouli; Elham Soltanimehr; Mohsen Ghofrani Jahromi; Zahra Sanaeian Pourshirazi
Journal:  Dentomaxillofac Radiol       Date:  2015-12-14       Impact factor: 2.419

6.  Anatomic study on mental canal and incisive nerve canal in interforaminal region in Chinese population.

Authors:  Yun Xu; Ning Suo; Xiufen Tian; Fei Li; Guangxin Zhong; Xiaoran Liu; Yongxing Bao; Tao Song; Hua Tian
Journal:  Surg Radiol Anat       Date:  2014-12-19       Impact factor: 1.246

7.  Cone Beam Computed Tomographic Analysis of the Course and Position of Mandibular Canal.

Authors:  Hooman Khorshidi; Saeed Raoofi; Janan Ghapanchi; Shoaleh Shahidi; Maryam Paknahad
Journal:  J Maxillofac Oral Surg       Date:  2016-09-09

8.  Morphometrical analysis of the human mandibular canal: a CT investigation.

Authors:  Marcello Rodrigues de Oliveira Júnior; André Luis Santos Saud; Debora Rodrigues Fonseca; Bernardo De-Ary-Pires; Mário Ary Pires-Neto; Ricardo de Ary-Pires
Journal:  Surg Radiol Anat       Date:  2010-07-31       Impact factor: 1.246

9.  Prevalence of bifid mandibular canals by cone beam computed tomography.

Authors:  Maria Fernanda Lima Villaça-Carvalho; Luiz Roberto Coutinho Manhães; Mari Eli Leonelli de Moraes; Sérgio Lúcio Pereira de Castro Lopes
Journal:  Oral Maxillofac Surg       Date:  2016-07-15

10.  The prevalence, length and position of the anterior loop of the inferior alveolar nerve in Chinese, assessed by spiral computed tomography.

Authors:  Xiao Li; Zhu-Kun Jin; Hui Zhao; Kai Yang; Jian-Min Duan; Wei-Jian Wang
Journal:  Surg Radiol Anat       Date:  2013-03-23       Impact factor: 1.246

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.